Honeywell Ademco Vista Series Commercial Burglary Partitioned Security System With Scheduling

Page 27

PROMPTEXPLANATION

02 START: PARTN

 

ANY PARTITION

0

If the starting event will be limited to occurring on a specific partition, enter the partition number (1-8) in which the start event will occur. Enter 0 for any partition.

Press [] to continue.

Do not use a zone programmed with an RF Button (Input Type BR) to STOP a relay. The system will not de- activate the relay.

PROMPTEXPLANATION

 

02

STOP: ZN LIST

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

02

STOP: ZN TYPE

 

 

NO RESPONSE

00

 

 

 

 

 

 

 

 

 

 

02

STOP: PARTN

 

 

ANY PARTITION

0

 

 

 

 

 

 

 

 

 

 

02

RELAY GROUP

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

02

RESTRICTION

 

 

1=YES 0=NO

0

 

 

 

 

 

 

 

 

 

 

02

RELAY TYPE

 

 

ECP

1

 

 

 

 

 

 

 

 

 

 

02

ECP ADDRESS

 

 

 

 

00

 

 

 

 

 

 

 

 

 

 

02

MODULE RELAY#

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

02

HOUSE CODE

 

 

A

 

00

 

 

If a zone list is being used to stop this relay action, enter the zone list number, 1-8. The restore of a zone on the zone list stops the relay. If a zone list is not being used, enter 0.

Press [] to continue.

If a Zone Type/System Operation is being used to stop the relay action, enter the 2-digit code listed in the Choices for Start/Stop System Operation chart.

Press [] to continue.

This is the partition to which the stop condition will be limited. Enter 0 for any partition. Enter 1-8for specific partition number.

Press [] to continue.

Relays may be grouped for common activation by time-driven events (commands 06-10). Enter 0 (no group) or 1-8for a specific group number.

Press [] to continue.

The system may have some devices that are not intended to be under end user control, such as relays activating fire doors or machinery. Enter 1 if the end user will be restricted from accessing this relay group.

Press [] to continue.

Enter 1 for (ECP) relay modules (4204). Enter 2 for X-10 devices.

Press [] to continue.

If you selected 1 (4204), enter the actual module’s address (01-15)as set by its DIP switches. Press [] to continue.

Enter the specific relay number on that module (1-4).

Press [] to continue.

The keypad will display the Start and Stop summary screens again.

Press [] to continue.

If you selected 2 for X-10 devices, enter the numerical equivalent of the House Code of the device, as follows:

A=00

D=03

G=06

J=09

M=12

P=15

B=01

E=04

H=07

K=10

N=13

 

C=02

F=05

I=08

L=11

O=14

 

 

 

 

 

 

 

02 UNIT CODE

00

Enter the numerical unit code of the X-10 device (00-15). Press [] to continue.

The keypad displays the Start and Stop summary screens again. Press [] to continue.

When all relays have been programmed, enter 00 at the "ENTER RELAY NO." prompt.

– 27 –

Image 27
Contents VISTA50P-PRV2 5/04 Rev a $0&29,67$65,6 9,67$39,67$38Table of Contents Recommended Programming Procedure Program Field Index Field GroupField Group VISTA-50P/VISTA-50PUL Programming Form 64 *67 Alarm Report Codes & ID Digits for Zones Enable OPEN/CLOSE Report forOPEN/CLOSE Report for Keyswitch 59 *62 Alarm Report Codes & ID Digits for Zones2nd Page Programming Fields press *94 Fields 1*28 1*31 are not applicable for UL installations3rd Page Programming Fields press *94 Summary of Programming Commands Partition-Specific Fields 1st Page Fields2nd Page Programming Fields press *94 Enable J7 Triggers by Partition #93 Menu Mode KEY Commands Programming With #93 Menu ModeZone Type PERIMETER03 Zone ProgrammingSET to CONFIRM? Enter Zone noInput Type Input S/N AXXX-XXXXInput S/N Xmit to Confirm Press to Skip Series Transmitters Loop DesignationsProgram field 200 Number of Partitions Expert Mode Zone ProgrammingOn this screen Input S/N XXX-XXXXEntering Wireless Keys From TemplatePartition Enter Zone no Zone Type Template Loop Function Wireless Key Default Templates 58045804BD Template Loop FunctionAlpha Descriptors Programming Zone Descriptors Select Zone Descriptor modeSelect the next word Select Default Screen modeSelect Custom Word Mode Accept the wordSave the word by pressing Type the word using one of two methods as followsFollow the same procedure as for custom words Enter the custom word number 01-20 you want to createSee the Relay Voice Descriptors section when Alpha Descriptor VocabularyVIP Module Device ProgrammingAlpha or Fixed-Word Keypad RF ExpanderTrouble AlarmFault Relay ProgrammingRelay Action No Response Start Event Not Used Relay Devices ProgrammingChoices for Start/Stop Zone Types and System Operations Enter Relay #Start Partn ANY Partition Relay Type ECP ECP Address Module RELAY# House CodeUnit Code Zone List Programming Relay Voice DescriptorsWord Index Custom Word no =QUIT Enter Index # Custom Word Substitutes for VIP Module AnnunciationSystem Definitions by Partition enter values or yes/no System Layout WorksheetsPartitions Communication Options by PartitionDevices keypads, 4204, rf receivers, vip module Access Codes & User Definitions for Partitions 1Printer Options Event LOG TypesAccess Codes & User Definitions for Partitions 3 Access Codes & User Definitions for Partitions 5Access Codes & User Definitions for Partitions 7 Zone Definition for Zones Zone Definition for Zones Zone Definition for Zones Zone Definition for Zones Zone Zone Definitions for System Zones 88 89, 90, 91, 97Zone Types Input TypesEvent Relay Devices WorksheetsApplicable only if relays 4204, or X-10 devices are used Device Action= Partition No -8, 0 = Any ZT = Zone TYPE/SYSTEM OperationScheduling Menu Prompts #80 & #81 Menu Mode KEY CommandsTime Window Number Scheduling WorksheetsStart Time Stop TimeW T F S S H HOLMonth/Day Partition Sched Num Time Window DaysOpen/Close Windows Relay commandsArm/Disarm commands Bypass commandsMon Tue Wed Thu Fri Sat Sun Partition/Windows Disarm WindowHhmm Arm WindowPartition/Windows Disarm Window Ademco VISTA-50P/VISTA-50PUL Summary of Connections VISTA50P-PRV2 5/04 Rev. a Eileen Way, Syosset, New York