If you are defining a zone list, continue to the next section. If not, enter 00 + [] at the next two prompts. You will then be asked "Quit Menu Mode?" Enter 1 for "Yes," 0 for "No." Then enter 99 to exit programming completely.

Zone List Programming

After all relays have been programmed, upon entering 00 at the "ENTER RELAY NO." prompt, you are asked to enter a zone list. If a zone list number was used to start or stop a relay, you must define the zones belonging to that list as follows:

PROMPTEXPLANATION

ENTER Zn LIST ?

0=QUIT0

01 ADD ZONE #

00=QUIT00

 

01

Del Zn LIST ?

 

 

1=YES

0=NO

0

 

 

 

 

 

 

 

 

 

 

01

DEL ZONES ?

 

 

1=YES

0=NO

0

 

 

 

 

 

 

 

 

 

 

 

01 Zn to DELETE ?

00=QUIT00

VIEW Zn LIST ?

0=QUIT0

01ASSIGNED ZONE

00=QUIT00

Enter the zone list number 1-8. Enter 0 to quit.

Using 2-digit entries, enter each zone to be included in this zone list. Press [] after you enter each zone number.

When you have entered all zones, enter 00. Press [] to continue.

Enter 0 to save this zone list. Enter 1 to delete it.

Enter 1 to delete one or more zones in that zone list. Enter 0 if no changes are necessary. If you enter 1, the following screen appears; otherwise, the "Enter Zone LIST" prompt reappears.

Enter each zone number to be deleted from the zone list, pressing [] after each number.

This display appears if you pressed 0 at the “Enter Zone LIST” prompt. Enter the zone list number that you wish to view.

Press [] to continue.

Press [] to scroll through all zones in that list. Enter 00 +[] to quit.

Press [1] to exit Menu Mode.

Press 99 to exit Program Mode.

Relay Voice Descriptors

If you are using the 4285/4286 VIP Module, voice descriptors can be programmed for the 16 outputs. These descriptors are announced by the voice module when you access the relays via the # 70 Relay Access Mode over the telephone.

Each voice descriptor can consist of up to 3 words selected from the Relay Voice Descriptors and Custom Word Substitutes Vocabulary list (later in this section).

The index numbers from this vocabulary list are to be used for relay voice descriptors only. For normal system voice annunciation (e.g., alarms, troubles, status), use the highlighted words in the alpha vocabulary list in the Alpha Programming part of this guide.

To enter relay voice descriptors, do the following:

1.From Data Field Programming mode, press #93 to display the "ZONE PROG?" prompt.

2.Press [0] (NO) to each menu option until the "RLY VOICE DESCR?" prompt is displayed. Follow the instructions below. While in this mode, press [] to advance to next screen. Press [#] to back up to previous screen.

PROMPTEXPLANATION

RLY VOICE DESCR?

 

1=YES 0=NO

0

Press [1] to program voice descriptors for relays.

ENTER RELAY NO.

00=QUIT 01

Enter the 2-digit relay number (01-32) for the relay desired, or enter 00 to quit Relay Voice Descriptor Programming Mode.

Press []

– 28 –

Image 28
Contents $0&29,67$65,6 9,67$39,67$38 VISTA50P-PRV2 5/04 Rev aTable of Contents Recommended Programming Procedure Field Group Program Field IndexField Group VISTA-50P/VISTA-50PUL Programming Form Enable OPEN/CLOSE Report for OPEN/CLOSE Report for Keyswitch59 *62 Alarm Report Codes & ID Digits for Zones 64 *67 Alarm Report Codes & ID Digits for ZonesFields 1*28 1*31 are not applicable for UL installations 2nd Page Programming Fields press *943rd Page Programming Fields press *94 Summary of Programming Commands 1st Page Fields Partition-Specific Fields2nd Page Programming Fields press *94 Enable J7 Triggers by Partition Programming With #93 Menu Mode #93 Menu Mode KEY CommandsZone Programming SET to CONFIRM?Enter Zone no Zone Type PERIMETER03Input S/N AXXX-XXXX Input TypeInput S/N Series Transmitters Loop Designations Xmit to Confirm Press to SkipExpert Mode Zone Programming Program field 200 Number of PartitionsInput S/N XXX-XXXX On this screenFrom Template Entering Wireless KeysPartition Enter Zone no Wireless Key Default Templates 5804 5804BDTemplate Loop Function Zone Type Template Loop FunctionZone Descriptors Select Zone Descriptor mode Alpha Descriptors ProgrammingSelect Default Screen mode Select Custom Word ModeAccept the word Select the next wordType the word using one of two methods as follows Follow the same procedure as for custom wordsEnter the custom word number 01-20 you want to create Save the word by pressingAlpha Descriptor Vocabulary See the Relay Voice Descriptors section whenDevice Programming Alpha or Fixed-Word KeypadRF Expander VIP ModuleAlarm FaultRelay Programming TroubleRelay Devices Programming Choices for Start/Stop Zone Types and System OperationsEnter Relay # Relay Action No Response Start Event Not UsedRelay Type ECP ECP Address Module RELAY# House Code Start Partn ANY PartitionUnit Code Relay Voice Descriptors Zone List ProgrammingWord Index Custom Word Substitutes for VIP Module Annunciation Custom Word no =QUIT Enter Index #System Layout Worksheets PartitionsCommunication Options by Partition System Definitions by Partition enter values or yes/noAccess Codes & User Definitions for Partitions 1 Printer OptionsEvent LOG Types Devices keypads, 4204, rf receivers, vip moduleAccess Codes & User Definitions for Partitions 5 Access Codes & User Definitions for Partitions 3Access Codes & User Definitions for Partitions 7 Zone Definition for Zones Zone Definition for Zones Zone Definition for Zones Zone Definition for Zones Zone Definitions for System Zones 88 89, 90, 91, 97 Zone TypesInput Types ZoneRelay Devices Worksheets Applicable only if relays 4204, or X-10 devices are usedDevice Action EventZT = Zone TYPE/SYSTEM Operation = Partition No -8, 0 = Any#80 & #81 Menu Mode KEY Commands Scheduling Menu PromptsScheduling Worksheets Start TimeStop Time Time Window NumberHOL Month/Day PartitionSched Num Time Window Days W T F S S HRelay commands Arm/Disarm commandsBypass commands Open/Close WindowsPartition/Windows Disarm Window HhmmArm Window Mon Tue Wed Thu Fri Sat SunPartition/Windows Disarm Window Ademco VISTA-50P/VISTA-50PUL Summary of Connections Eileen Way, Syosset, New York VISTA50P-PRV2 5/04 Rev. a