Honeywell Ademco Vista Series Commercial Burglary Partitioned Security System With Scheduling

Page 15

5800 Series Transmitters Loop Designations

 

LOOP 3

 

 

 

 

LOOP 2

 

 

 

 

LOOP 1

 

 

 

 

 

 

 

LOOP

 

LOOP 4

 

 

1

 

 

 

 

 

YOU MUST

 

 

 

 

ENROLL THIS

 

 

 

 

BUTTON

 

 

 

5801

 

 

5 8 0 2 M N

ENROLL AS "UR" OR "RF"

ENROLL AS "UR" OR "RF"

YOU MUST

LOOP 3

 

 

 

 

 

 

 

ENROLL THIS

 

 

 

 

BUTTON

LOOP 2

 

 

 

LOOP 4

 

 

 

LOOP 1

 

 

 

 

 

 

LOOP 2

 

 

 

 

YOU MUST

 

 

 

 

ENROLL THIS

 

 

 

 

BUTTON

 

 

 

 

LOOP 4

 

 

 

 

LOOP 1

5 8 0 4

LOOP 3

 

 

 

 

••

 

ENROLL

 

 

 

•••••

SET

 

 

• ••• •

AS "BR"

 

• •

HOUSE

 

 

 

 

 

CODE

 

 

5804BD

 

 

 

ENROLL AS "BR"

 

LOOP

 

 

 

 

1

 

 

 

5809

 

 

 

 

ENROLL AS "RF"

 

 

 

 

 

 

 

 

LOOP 2

 

 

 

 

(REED)

LOOP

 

 

 

 

1

 

 

LOOP 1

 

 

 

 

(TERMINALS)

5808

 

5 8 1 6

 

ENROLL AS "RF"

 

ENROLL AS "RF"

 

 

LOOP 2

 

LOOP 1

 

 

(REED)

 

 

 

 

(PRIMARY)

 

 

 

 

 

 

 

 

LOOP 2

 

 

 

 

(AUX. CENTER)

 

 

LOOP 1

 

 

 

 

(TERMINALS)

LOOP 3

 

 

 

 

ALTERNATE

 

 

 

(AUX. RIGHT)

POSITION

 

5 8 1 6 M N

 

5 8 1 7

FOR LOOP 2

 

 

 

ENROLL AS "RF"

 

ENROLL AS "RF"

 

 

 

 

LOOP 2

 

LOOP

 

 

(REED)

 

 

LOOP 1

 

 

2

 

 

 

 

(TERMINALS)

 

 

(REED)

 

 

 

 

 

 

 

 

 

 

 

LOOP 1

 

 

 

LOOP 3

(INTERNAL

 

 

(TERMINALS)

SHOCK

 

 

 

 

SENSOR)

LOOP 3

 

 

 

 

(TERMINALS)

 

 

 

 

 

5 8 1 9

 

5819S (WHS & BRS)

ENROLL AS "RF"

 

ENROLL AS "RF"

 

5 8 2 7

 

 

5 8 2 7 B D

SET HOUSE CODE

 

SET HOUSE CODE

LOOP 1 (MOTION)

(Green) (Red) (Yellow)

5850 (GBD)

5 8 9 0

ENROLL AS "RF"

ENROLL AS "RF"

5800_trans_loop-V0

Note: For information on any transmitter not shown above, refer to the instructions accompanying that transmitter for details regarding loop numbers, etc.

 

 

UL

The 5802MN, 5802MN2, 5804, 5804BD, 5814, 5816TEMP, 5819, 5819WHS & BRS, 5827BD,

 

 

and 5850 transmitters are not intended for use in UL installations.

 

 

 

 

 

 

 

 

 

 

 

 

 

PROMPT

 

 

EXPLANATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XMIT TO CONFIRM PRESS TO SKIP

Entd A022-4063 1

Rcvd A022-4064

Confirmation Option: This prompt only appears if you answered “Yes” at the first prompt. The system enters a confirmation mode so that the operation of the actual programmed input can be confirmed. Activate the loop input or button that corresponds to this zone. At any time during this step, you may press the [] key on the keypad to save the serial and loop number combination without confirming.

If the serial number transmitted does not match the serial number entered, a display similar to the one at the left appears. If the loop number does not match, it is also displayed.

If so, activate the loop input or button on the transmitter once again. If a match is not obtained (i.e., summary display does not appear), press the [#] key twice and then enter or transmit the correct serial number.

10 ZT P RC In L

03 1 3C RF 1s

If the serial number transmitted does match the serial number entered, the system beeps 3 times and a summary display appears, showing that zone’s programming. Note that an “s” indicates that a transmitter’s serial number has been enrolled.

Press [] to accept the zone information.

– 15 –

Image 15
Contents VISTA50P-PRV2 5/04 Rev a $0&29,67$65,6 9,67$39,67$38Table of Contents Recommended Programming Procedure Program Field Index Field GroupField Group VISTA-50P/VISTA-50PUL Programming Form 64 *67 Alarm Report Codes & ID Digits for Zones Enable OPEN/CLOSE Report forOPEN/CLOSE Report for Keyswitch 59 *62 Alarm Report Codes & ID Digits for Zones2nd Page Programming Fields press *94 Fields 1*28 1*31 are not applicable for UL installations3rd Page Programming Fields press *94 Summary of Programming Commands Partition-Specific Fields 1st Page Fields2nd Page Programming Fields press *94 Enable J7 Triggers by Partition #93 Menu Mode KEY Commands Programming With #93 Menu ModeZone Type PERIMETER03 Zone ProgrammingSET to CONFIRM? Enter Zone noInput Type Input S/N AXXX-XXXXInput S/N Xmit to Confirm Press to Skip Series Transmitters Loop DesignationsProgram field 200 Number of Partitions Expert Mode Zone ProgrammingOn this screen Input S/N XXX-XXXXEntering Wireless Keys From TemplatePartition Enter Zone no Zone Type Template Loop Function Wireless Key Default Templates 58045804BD Template Loop FunctionAlpha Descriptors Programming Zone Descriptors Select Zone Descriptor modeSelect the next word Select Default Screen modeSelect Custom Word Mode Accept the wordSave the word by pressing Type the word using one of two methods as followsFollow the same procedure as for custom words Enter the custom word number 01-20 you want to createSee the Relay Voice Descriptors section when Alpha Descriptor VocabularyVIP Module Device ProgrammingAlpha or Fixed-Word Keypad RF ExpanderTrouble AlarmFault Relay ProgrammingRelay Action No Response Start Event Not Used Relay Devices ProgrammingChoices for Start/Stop Zone Types and System Operations Enter Relay #Start Partn ANY Partition Relay Type ECP ECP Address Module RELAY# House CodeUnit Code Zone List Programming Relay Voice DescriptorsWord Index Custom Word no =QUIT Enter Index # Custom Word Substitutes for VIP Module AnnunciationSystem Definitions by Partition enter values or yes/no System Layout WorksheetsPartitions Communication Options by PartitionDevices keypads, 4204, rf receivers, vip module Access Codes & User Definitions for Partitions 1Printer Options Event LOG TypesAccess Codes & User Definitions for Partitions 3 Access Codes & User Definitions for Partitions 5Access Codes & User Definitions for Partitions 7 Zone Definition for Zones Zone Definition for Zones Zone Definition for Zones Zone Definition for Zones Zone Zone Definitions for System Zones 88 89, 90, 91, 97Zone Types Input TypesEvent Relay Devices WorksheetsApplicable only if relays 4204, or X-10 devices are used Device Action= Partition No -8, 0 = Any ZT = Zone TYPE/SYSTEM OperationScheduling Menu Prompts #80 & #81 Menu Mode KEY CommandsTime Window Number Scheduling WorksheetsStart Time Stop TimeW T F S S H HOLMonth/Day Partition Sched Num Time Window DaysOpen/Close Windows Relay commandsArm/Disarm commands Bypass commandsMon Tue Wed Thu Fri Sat Sun Partition/Windows Disarm WindowHhmm Arm WindowPartition/Windows Disarm Window Ademco VISTA-50P/VISTA-50PUL Summary of Connections VISTA50P-PRV2 5/04 Rev. a Eileen Way, Syosset, New York