Honeywell Vista-50P/Vista-50PUL manual Custom Word Substitutes for VIP Module Annunciation

Page 30

Custom Word Substitutes for VIP Module Annunciation

A substitute word can be programmed for each of the 20 custom words used in your alpha zone descriptions. The VIP Module announces this substitute word in place of the custom word that is displayed on the alpha keypad. For example, an alarm display of "John’s Bedroom" could be announced as "Son’s Bedroom," as there is no annunciation for the custom word "John." Note that if a substitute word is not assigned, the VIP Module will not annunciate the zone descriptor at all, but will only annunciate the zone number.

To enter custom word substitutes, do the following:

1.From Data Field Programming Mode, press #93 to display the "ZONE PROG?" prompt.

2.Press [0] (NO) to each menu option until the "CUSTOM INDEX ?" prompt is displayed.

PROMPTEXPLANATION

CUSTOM INDEX ?

 

1=YES 0=NO

0

CUSTOM WORD NO. 00=QUIT

01 ENTER INDEX #

Enter [1] at this prompt.

Enter the custom word number (01-20) for which a voice substitute is desired. Enter 00 to quit this Programming Mode.

Press [] to accept entry.

Enter the 3-digit substitute word index number from the Relay Voice Descriptors and Custom Word Substitutes Vocabulary list in the Relay Voice Descriptors part of this section.

Press [] to accept entry.

The "CUSTOM WORD NO." prompt is displayed. Enter the next custom word number to be substituted, or enter 00 to quit.

– 30 –

Image 30
Contents $0&29,67$65,6 9,67$39,67$38 VISTA50P-PRV2 5/04 Rev aTable of Contents Recommended Programming Procedure Program Field Index Field GroupField Group VISTA-50P/VISTA-50PUL Programming Form 59 *62 Alarm Report Codes & ID Digits for Zones Enable OPEN/CLOSE Report forOPEN/CLOSE Report for Keyswitch 64 *67 Alarm Report Codes & ID Digits for ZonesFields 1*28 1*31 are not applicable for UL installations 2nd Page Programming Fields press *943rd Page Programming Fields press *94 Summary of Programming Commands Partition-Specific Fields 1st Page Fields2nd Page Programming Fields press *94 Enable J7 Triggers by Partition Programming With #93 Menu Mode #93 Menu Mode KEY CommandsEnter Zone no Zone ProgrammingSET to CONFIRM? Zone Type PERIMETER03Input Type Input S/N AXXX-XXXXInput S/N Series Transmitters Loop Designations Xmit to Confirm Press to SkipExpert Mode Zone Programming Program field 200 Number of PartitionsInput S/N XXX-XXXX On this screenEntering Wireless Keys From TemplatePartition Enter Zone no Template Loop Function Wireless Key Default Templates 58045804BD Zone Type Template Loop FunctionZone Descriptors Select Zone Descriptor mode Alpha Descriptors ProgrammingAccept the word Select Default Screen modeSelect Custom Word Mode Select the next wordEnter the custom word number 01-20 you want to create Type the word using one of two methods as followsFollow the same procedure as for custom words Save the word by pressingAlpha Descriptor Vocabulary See the Relay Voice Descriptors section whenRF Expander Device ProgrammingAlpha or Fixed-Word Keypad VIP ModuleRelay Programming AlarmFault TroubleEnter Relay # Relay Devices ProgrammingChoices for Start/Stop Zone Types and System Operations Relay Action No Response Start Event Not UsedStart Partn ANY Partition Relay Type ECP ECP Address Module RELAY# House CodeUnit Code Relay Voice Descriptors Zone List ProgrammingWord Index Custom Word Substitutes for VIP Module Annunciation Custom Word no =QUIT Enter Index #Communication Options by Partition System Layout WorksheetsPartitions System Definitions by Partition enter values or yes/noEvent LOG Types Access Codes & User Definitions for Partitions 1Printer Options Devices keypads, 4204, rf receivers, vip moduleAccess Codes & User Definitions for Partitions 3 Access Codes & User Definitions for Partitions 5Access Codes & User Definitions for Partitions 7 Zone Definition for Zones Zone Definition for Zones Zone Definition for Zones Zone Definition for Zones Input Types Zone Definitions for System Zones 88 89, 90, 91, 97Zone Types ZoneDevice Action Relay Devices WorksheetsApplicable only if relays 4204, or X-10 devices are used EventZT = Zone TYPE/SYSTEM Operation = Partition No -8, 0 = Any#80 & #81 Menu Mode KEY Commands Scheduling Menu PromptsStop Time Scheduling WorksheetsStart Time Time Window NumberSched Num Time Window Days HOLMonth/Day Partition W T F S S HBypass commands Relay commandsArm/Disarm commands Open/Close WindowsArm Window Partition/Windows Disarm WindowHhmm Mon Tue Wed Thu Fri Sat SunPartition/Windows Disarm Window Ademco VISTA-50P/VISTA-50PUL Summary of Connections Eileen Way, Syosset, New York VISTA50P-PRV2 5/04 Rev. a