Honeywell Ademco Vista Series Commercial Burglary Partitioned Security System With Scheduling

Page 31

System Layout Worksheets

Before programming any security system, you should first define the installation. To help you lay out a partitioned system, use the following worksheets. This will further simplify the programming process.

PARTITIONS

Partition #

Descriptor (4-char max)

Prim. Sub. #

Sec. Sub. #

Alpha Default Message (32-character maximum)

Partition 1

Partition 2

Partition 3

Partition 4

Partition 5

Partition 6

Partition 7

Partition 8

Keyswitch Arming Partition Assignment (1-8):

Wireless Keypad Partition Assignment (1-8):

Voice Module Partition Assignment (1-8):

Use Partition Descriptor (yes/no)?

Common Lobby Partition Assignment (1-8):

COMMUNICATION OPTIONS BY PARTITION

Option

Part. 1 Part. 2 Part. 3 Part. 4 Part. 5 Part. 6 Part. 7 Part. 8

Swinger Suppression Count 00-15; 00=no suppression

Cancel Report After Disarm

Dialer Reports for Panic (* + 1)

Dialer Reports for Panic (# + 3)

Dialer Reports for Panic (* + #)

Dialer Reports for Duress

Burglary Alarm Communications Delay (16 sec.)

SYSTEM DEFINITIONS BY PARTITION (enter values or yes/no)

Option

Part. 1 Part. 2 Part. 3 Part. 4 Part. 5 Part. 6 Part. 7 Part. 8

Entry Delay #1 (00, 30-225 seconds):

Exit Delay #1 (00, 45-225 seconds):

Entry Delay #2 (00, 30-225 seconds):

Exit Delay #2 (00, 45-225 seconds):

Quick Arming

Multiple Alarms per Arming

Console Panic for Zone 95 (* + 1)

Console Panic for Zone 96 (# + 3)

Console Panic for Zone 99 (* + #)

Allow Sign-on (GOTO function)

Non-Bypassable Zone*

Sounder Timeout Duration for Bell (2 min. increments)

Console Annunciation During Entry**

Console Annunciation During Exit

Confirmation of Arming Ding for Bell

Chime on Bell

Access Control Relay (field 1*76)

Affects Lobby (check partitions that apply)

Arms Lobby (check partitions that apply)

*Can be any zone 01-86. **no= 3 beeps

yes=continuous

– 31 –

Image 31
Contents VISTA50P-PRV2 5/04 Rev a $0&29,67$65,6 9,67$39,67$38Table of Contents Recommended Programming Procedure Field Group Program Field IndexField Group VISTA-50P/VISTA-50PUL Programming Form 64 *67 Alarm Report Codes & ID Digits for Zones Enable OPEN/CLOSE Report forOPEN/CLOSE Report for Keyswitch 59 *62 Alarm Report Codes & ID Digits for Zones2nd Page Programming Fields press *94 Fields 1*28 1*31 are not applicable for UL installations3rd Page Programming Fields press *94 Summary of Programming Commands 1st Page Fields Partition-Specific Fields2nd Page Programming Fields press *94 Enable J7 Triggers by Partition #93 Menu Mode KEY Commands Programming With #93 Menu ModeZone Type PERIMETER03 Zone ProgrammingSET to CONFIRM? Enter Zone noInput S/N AXXX-XXXX Input TypeInput S/N Xmit to Confirm Press to Skip Series Transmitters Loop DesignationsProgram field 200 Number of Partitions Expert Mode Zone ProgrammingOn this screen Input S/N XXX-XXXXFrom Template Entering Wireless KeysPartition Enter Zone no Zone Type Template Loop Function Wireless Key Default Templates 58045804BD Template Loop FunctionAlpha Descriptors Programming Zone Descriptors Select Zone Descriptor modeSelect the next word Select Default Screen modeSelect Custom Word Mode Accept the wordSave the word by pressing Type the word using one of two methods as followsFollow the same procedure as for custom words Enter the custom word number 01-20 you want to createSee the Relay Voice Descriptors section when Alpha Descriptor VocabularyVIP Module Device ProgrammingAlpha or Fixed-Word Keypad RF ExpanderTrouble AlarmFault Relay ProgrammingRelay Action No Response Start Event Not Used Relay Devices ProgrammingChoices for Start/Stop Zone Types and System Operations Enter Relay #Relay Type ECP ECP Address Module RELAY# House Code Start Partn ANY PartitionUnit Code Zone List Programming Relay Voice DescriptorsWord Index Custom Word no =QUIT Enter Index # Custom Word Substitutes for VIP Module AnnunciationSystem Definitions by Partition enter values or yes/no System Layout WorksheetsPartitions Communication Options by PartitionDevices keypads, 4204, rf receivers, vip module Access Codes & User Definitions for Partitions 1Printer Options Event LOG TypesAccess Codes & User Definitions for Partitions 5 Access Codes & User Definitions for Partitions 3Access Codes & User Definitions for Partitions 7 Zone Definition for Zones Zone Definition for Zones Zone Definition for Zones Zone Definition for Zones Zone Zone Definitions for System Zones 88 89, 90, 91, 97Zone Types Input TypesEvent Relay Devices WorksheetsApplicable only if relays 4204, or X-10 devices are used Device Action= Partition No -8, 0 = Any ZT = Zone TYPE/SYSTEM OperationScheduling Menu Prompts #80 & #81 Menu Mode KEY CommandsTime Window Number Scheduling WorksheetsStart Time Stop TimeW T F S S H HOLMonth/Day Partition Sched Num Time Window DaysOpen/Close Windows Relay commandsArm/Disarm commands Bypass commandsMon Tue Wed Thu Fri Sat Sun Partition/Windows Disarm WindowHhmm Arm WindowPartition/Windows Disarm Window Ademco VISTA-50P/VISTA-50PUL Summary of Connections VISTA50P-PRV2 5/04 Rev. a Eileen Way, Syosset, New York