Honeywell Ademco Vista Series Commercial Burglary Partitioned Security System With Scheduling

Page 41

Zone List 7: Started or stopped by zone numbers (enter 000 to end entries).

Zone List 8: Started or stopped by zone numbers (enter 000 to end entries).

Scheduling Menu Prompts

To program schedules, enter Scheduling program mode by pressing [User Code] + # + 80 to display the first choice of the menu driven programming functions. NOTE: Only users with an Installer or Master level user code may enter the #80 mode.

Press 0 (NO) or 1 (YES) in response to the displayed menu selection. Pressing 0 will display the next choice in sequence. Menu selections are as follows:

PROMPTEXPLANATION

 

Time Window ?

 

 

1 = YES

0 = NO

0

 

 

 

 

 

 

 

 

O/C Schedules ?

 

 

1 = YES

0 = NO

0

 

 

 

 

 

 

 

 

 

 

Holidays

?

 

 

1 = YES

0 = NO

0

 

 

 

 

 

 

 

 

Timed Events ?

 

 

1 = YES

0 = NO

0

 

Access Sched. ?

1 = YES 0 = NO 0

For defining up to 20 time windows each with a start and a stop time programmed by entering the hours and minutes.

For defining the daily open and close schedules for the 8 partitions. Each partition can be programmed with an opening and closing window for each day of the week and holidays.

For defining up to 16 holidays for which partitions they apply.

For defining up to 20 time driven events with the following parameters:

Time window

Action desired

Action specifier

Activation time

Days of the week

For defining the limitation of access schedules for the user codes. Each schedule can be programmed with two window for each day of the week and holidays

#80 & #81 MENU MODE KEY COMMANDS

The following is a list of commands used while in the Menu mode.

#80 or #81

[4]

[#]

0

1

01-09

00

Enters Menu mode

Serves as ENTER key. Press to have keypad accept entry.

Backs up to previous screen.

Press to answer NO.

Press to answer YES.

All data entries are either 2-digit entries.

Exits Menu mode, returns to normal operation mode when entered at the first question for each category.

— 41 —

Image 41
Contents VISTA50P-PRV2 5/04 Rev a $0&29,67$65,6 9,67$39,67$38Table of Contents Recommended Programming Procedure Field Group Program Field IndexField Group VISTA-50P/VISTA-50PUL Programming Form OPEN/CLOSE Report for Keyswitch Enable OPEN/CLOSE Report for59 *62 Alarm Report Codes & ID Digits for Zones 64 *67 Alarm Report Codes & ID Digits for Zones2nd Page Programming Fields press *94 Fields 1*28 1*31 are not applicable for UL installations3rd Page Programming Fields press *94 Summary of Programming Commands 2nd Page Programming Fields press *94 Partition-Specific Fields1st Page Fields Enable J7 Triggers by Partition #93 Menu Mode KEY Commands Programming With #93 Menu ModeSET to CONFIRM? Zone ProgrammingEnter Zone no Zone Type PERIMETER03Input S/N Input TypeInput S/N AXXX-XXXX Xmit to Confirm Press to Skip Series Transmitters Loop DesignationsProgram field 200 Number of Partitions Expert Mode Zone ProgrammingOn this screen Input S/N XXX-XXXXPartition Enter Zone no Entering Wireless KeysFrom Template 5804BD Wireless Key Default Templates 5804Template Loop Function Zone Type Template Loop FunctionAlpha Descriptors Programming Zone Descriptors Select Zone Descriptor modeSelect Custom Word Mode Select Default Screen modeAccept the word Select the next wordFollow the same procedure as for custom words Type the word using one of two methods as followsEnter the custom word number 01-20 you want to create Save the word by pressingSee the Relay Voice Descriptors section when Alpha Descriptor VocabularyAlpha or Fixed-Word Keypad Device ProgrammingRF Expander VIP ModuleFault AlarmRelay Programming TroubleChoices for Start/Stop Zone Types and System Operations Relay Devices ProgrammingEnter Relay # Relay Action No Response Start Event Not UsedUnit Code Start Partn ANY PartitionRelay Type ECP ECP Address Module RELAY# House Code Zone List Programming Relay Voice DescriptorsWord Index Custom Word no =QUIT Enter Index # Custom Word Substitutes for VIP Module AnnunciationPartitions System Layout WorksheetsCommunication Options by Partition System Definitions by Partition enter values or yes/noPrinter Options Access Codes & User Definitions for Partitions 1Event LOG Types Devices keypads, 4204, rf receivers, vip moduleAccess Codes & User Definitions for Partitions 7 Access Codes & User Definitions for Partitions 3Access Codes & User Definitions for Partitions 5 Zone Definition for Zones Zone Definition for Zones Zone Definition for Zones Zone Definition for Zones Zone Types Zone Definitions for System Zones 88 89, 90, 91, 97Input Types ZoneApplicable only if relays 4204, or X-10 devices are used Relay Devices WorksheetsDevice Action Event= Partition No -8, 0 = Any ZT = Zone TYPE/SYSTEM OperationScheduling Menu Prompts #80 & #81 Menu Mode KEY CommandsStart Time Scheduling WorksheetsStop Time Time Window NumberMonth/Day Partition HOLSched Num Time Window Days W T F S S HArm/Disarm commands Relay commandsBypass commands Open/Close WindowsHhmm Partition/Windows Disarm WindowArm Window Mon Tue Wed Thu Fri Sat SunPartition/Windows Disarm Window Ademco VISTA-50P/VISTA-50PUL Summary of Connections VISTA50P-PRV2 5/04 Rev. a Eileen Way, Syosset, New York