Recommended Programming Procedure

The following is a step-by-step procedure recommended for programming your VISTA-50P/VISTA-50PUL system.

1.Set the keypads (and other peripheral devices) to the appropriate addresses.

2.Set factory defaults by pressing 97.

This will automatically enable keypad addresses 00-03, so be sure at least one keypad is set to one of these addresses.

3.Program system-wide (global) data fields.

Using the programming form as a guide, enter program mode and program all system-wide programming fields. These options affect the entire system, regardless of partitions. They include control options, downloader and dialer options, RF options, event logging options, etc. Refer to the Program Field Index for a listing of the program fields and their function.

Note that field 200 (number of partitions) must be programmed before continuing.

4.Program partition-specific fields.

When the system-wide fields have been programmed, program all partition-specific programming fields by first pressing 91 to select a partition (while still in data field program mode). Then enter the first partition- specific field number 09. When you are finished, the next partition-specific field is automatically displayed. Partition-specific fields can have different values for each partition. To program the fields for the next partition, press 91, enter the desired partition number, then enter field 09. Refer to the PROGRAMMING section in the ADEMCO VISTA-50P/VISTA-50PUL Installation and Setup Guide for detailed instructions.

5.Use #93 Menu Mode for device programming.

Refer to Device Programming in this guide to assign keypad ID numbers and default partitions for each keypad, and to selectively suppress certain keypad sounding options. Also use this mode to assign RF receivers, relay modules, the VIP module, the ECP Long Range Radio, and the VISTA Gateway Module.

6.Use #93 Menu Mode for zone programming.

Refer to Zone Programming in this guide to program zone response types, assign right loop zones and wireless zones, assign zones to partitions, and to program alarm report codes.

7.Use #93 Menu Mode for programming outputs.

Refer to Output Programming in this guide to program desired output operation.

8.Program Communication options.

Refer to System Communication section in the ADEMCO VISTA-50P/VISTA-50PUL Installation and Setup Guide for detailed instructions. Then use #93 menu mode to program report codes.

9.Use #93 Menu Mode for programming alpha descriptors.

Refer to Alpha Programming in this guide to enter zone and partition descriptors and a custom installer’s message.

10.Use #93 Menu Mode for relay voice descriptors and custom word substitutes.

Refer to Relay Voice Descriptors in this guide for further instructions for programming relay descriptors to be annunciated by the VIP module, as well as the Custom Index section for custom word substitutes.

11.Use #80 Mode for programming schedules.

Refer to the Scheduling Menu Prompts in the ADEMCO VISTA-50P/VISTA-50PUL Installation and Setup Guide to program open/close schedules, temporary and holiday schedules, limitation of access schedules, and time-driven events.

12.Define user access codes.

Refer to User Access Codes in the ADEMCO VISTA-50P/VISTA-50PUL Installation and Setup Guide to program authority level, O/C reporting option, partition assignments, and RF key assignments for each user.

13.Exit Programming Mode.

Exit programming mode by pressing either 98 or 99. Additional entries of 99 are required if the exit is being done from fields 100 and above.

To prevent re-access to programming mode using the Installer’s code, use 98. The only way to re-access programming mode is by depressing both the [] and [#] keys at the same time within 30 seconds of power- up.

Exiting by using 99 always allows reentry into programming mode using the Installer code. Either way of exiting allows access via downloading. Note that if local programming lockout is set via downloading, programming mode cannot be entered at the keypad.

3 –

Image 3
Contents VISTA50P-PRV2 5/04 Rev a $0&29,67$65,6 9,67$39,67$38Table of Contents Recommended Programming Procedure Program Field Index Field GroupField Group VISTA-50P/VISTA-50PUL Programming Form 64 *67 Alarm Report Codes & ID Digits for Zones Enable OPEN/CLOSE Report forOPEN/CLOSE Report for Keyswitch 59 *62 Alarm Report Codes & ID Digits for Zones2nd Page Programming Fields press *94 Fields 1*28 1*31 are not applicable for UL installations3rd Page Programming Fields press *94 Summary of Programming Commands Partition-Specific Fields 1st Page Fields2nd Page Programming Fields press *94 Enable J7 Triggers by Partition #93 Menu Mode KEY Commands Programming With #93 Menu ModeZone Type PERIMETER03 Zone ProgrammingSET to CONFIRM? Enter Zone noInput Type Input S/N AXXX-XXXXInput S/N Xmit to Confirm Press to Skip Series Transmitters Loop DesignationsProgram field 200 Number of Partitions Expert Mode Zone ProgrammingOn this screen Input S/N XXX-XXXXEntering Wireless Keys From TemplatePartition Enter Zone no Zone Type Template Loop Function Wireless Key Default Templates 58045804BD Template Loop FunctionAlpha Descriptors Programming Zone Descriptors Select Zone Descriptor modeSelect the next word Select Default Screen modeSelect Custom Word Mode Accept the wordSave the word by pressing Type the word using one of two methods as followsFollow the same procedure as for custom words Enter the custom word number 01-20 you want to createSee the Relay Voice Descriptors section when Alpha Descriptor VocabularyVIP Module Device ProgrammingAlpha or Fixed-Word Keypad RF ExpanderTrouble AlarmFault Relay ProgrammingRelay Action No Response Start Event Not Used Relay Devices ProgrammingChoices for Start/Stop Zone Types and System Operations Enter Relay #Start Partn ANY Partition Relay Type ECP ECP Address Module RELAY# House CodeUnit Code Zone List Programming Relay Voice DescriptorsWord Index Custom Word no =QUIT Enter Index # Custom Word Substitutes for VIP Module AnnunciationSystem Definitions by Partition enter values or yes/no System Layout WorksheetsPartitions Communication Options by PartitionDevices keypads, 4204, rf receivers, vip module Access Codes & User Definitions for Partitions 1Printer Options Event LOG TypesAccess Codes & User Definitions for Partitions 3 Access Codes & User Definitions for Partitions 5Access Codes & User Definitions for Partitions 7 Zone Definition for Zones Zone Definition for Zones Zone Definition for Zones Zone Definition for Zones Zone Zone Definitions for System Zones 88 89, 90, 91, 97Zone Types Input TypesEvent Relay Devices WorksheetsApplicable only if relays 4204, or X-10 devices are used Device Action= Partition No -8, 0 = Any ZT = Zone TYPE/SYSTEM OperationScheduling Menu Prompts #80 & #81 Menu Mode KEY CommandsTime Window Number Scheduling WorksheetsStart Time Stop TimeW T F S S H HOLMonth/Day Partition Sched Num Time Window DaysOpen/Close Windows Relay commandsArm/Disarm commands Bypass commandsMon Tue Wed Thu Fri Sat Sun Partition/Windows Disarm WindowHhmm Arm WindowPartition/Windows Disarm Window Ademco VISTA-50P/VISTA-50PUL Summary of Connections VISTA50P-PRV2 5/04 Rev. a Eileen Way, Syosset, New York