Bosch Appliances Features in D7212G, Compatible Accessories, Introduction, Ground Fault Detect

Page 16

D7212G

Overview

2.2.1Compatible Accessories

See the Bosch Security Systems Intrusion Catalog for a complete list.

D122

Dual Battery Harness

D125B

Powered Loop

 

Interface Module

D126

12 V, 7 Ah

 

Rechargeable Battery

D127

Reversing Relay

D129

Dual Class A Initiation

 

Circuit Module

D130

Relay Module

D136

Plug-In Relay

D161

Phone Cord

D162

Phone Cord

D185

Reverse Polarity

 

Module

D192C/D192G

Bell Circuit

 

Supervision Module

D279A

Independent Zone

 

Control (On-Board

 

and OctoPOPIT

 

Points)

D442

Bells (10 in.)

D448/D449

Mini-Horns

D720

Command Center

 

(Area LED)

D720R

LED Command

 

Center (red)

D720W

LED Command

 

Center (white)

D1218

12 V, 17.2 Ah

 

Rechargeable Battery

D1255

Command Center

 

(General Purpose)

D1255R

Command Center

 

(red)

D1255W

Command Center

 

(white)

D1256

Fire Command Center

D1257

Fire Annunciator

D1260

Alpha V Command Center

D1640

16.5 VAC 40 VA Transformer

D5200

Programmer

D5500

Remote Account Manager IV

D8004

Transformer Enclosure

D8121A,

Derived Channel STU

D8122

 

D8125

POPEX Module

D8125MUX

Multiplex Bus Interface

D125INV*

Wireless Interface Module

D8128D

OctoPOPIT Module

D8129

OctoRelay Module

D8130

Release Module

D9127U/T

POPIT Module

D9131A

Parallel Printer Interface Module

ZX776Z

PIR Motion Sensor (50 ft.) with

 

POPIT

ZX794Z

PIR Motion Sensor (80 ft.) with

 

POPIT

ZX835

PIR/Microwave Motion Sensor

 

(35 ft.)

Z938Z

PIR Motion Sensor (60 ft.) with

 

POPIT

ZX970

PIR/Microwave Motion Sensor

 

(70 ft.) with POPIT

* The D8125INV has not been investigated by UL. Not to be used in UL Listed installations.

2.3Features in D7212G

2.3.1Introduction

The Bosch Security Systems D7212G Control/Communicator provides up to 40 points of protection and supports up to four separate areas. The panel is armed and disarmed by area, and several areas can be armed and disarmed with one menu function. The D7212G uses a built-in digital communicator to send reports to the receiver. A maximum of 32 unsupervised command centers can be connected to the system.

2.3.2Ground Fault Detect

In order for the D7212G to be able to detect ground fault conditions, the Earth Ground Terminal on the control/ communicators had to be electrically isolated from all other terminals. A Ground Fault Detect Enable switch (S4) has been added to the panel and is located just under Terminal 10, Earth Ground. For more information on the operation of this function, see Section 3.5.2 Ground Fault Detect Enable on page 22.

D7212G Operation and Installation Guide

4998138544C

Page 16

© 2003 Bosch Security Systems

Image 16
Contents Control/Communicator D7212G Operation and Installation Guide D7212GContents 11.1 10.111.2 10.0 11.013.0 Figures D7212G Operation and Installation Guide Organization TablesIntroduction Guide OrganizationSection Description Appendix DescriptionDocumentation Conventions Related DocumentationType Styles Used in the Text Tips, Notes, Cautions and Warnings FCC RulesPart D7212G Overview New Features D9412G D7412G D7212G9000G Series Panel Differences Specifications SecondaryTelephone Connections Telephone Line Features in D7212G Compatible AccessoriesGround Fault Detect IntroductionStandard Features Model Display Application Control/Communicator Assembly Other FeaturesComponents and Literature Available by Separate Order Burglary Listings and ApprovalsListings Installation Beginning the InstallationBefore Beginning Enclosure OptionsInstalling the Assembly Connecting Earth GroundGround Fault Detect Enable Locking the Reset PinFinishing the Installation Charge the Battery While FinishingInstall and Wire Detection Devices Install Modules and RelaysTesting the System Install the Point Chart LabelProgramming the Panel Primary Power Terminals Power SupplySecondary Power Terminals Installing the Battery Replacing the BatteryBattery Supervision Battery Charging Circuit Float ChargeBattery Discharge/Recharge Schedule Discharge CycleCharging Status and Low Battery LEDs TypeAction Color StatePower Outputs Total Available PowerAux Power Terminals Continuous Current Draw Programmable Power Outputs TerminalsRelay Installation Available PowerFire System Power Formula Verification/Reset RelayTelephone Connections Operation Monitor LED Green Dialing FormatPhone Line Monitor Called Party DisconnectGround Start Phone Monitor Select JumperLoop Start Position Ground StartD7212G On-board Points Description TerminalsPoint Sensor Loops Point ParametersBell Off-board Points Point Zonex Bus D7212G TerminalsInstalling the D8125 Popex Module D8125, D8127 and D9127 Popit ModulesWiring Data Expansion Loops to Popex Modules Expansion Loops CombinedLength in ft. m Popit Sensor LoopsConnecting the D8125 Popex to the D7212G Panel Program Record Sheet Popit Module Point AssignmentsRadxpnts Handler Installing the OctoPOPIT D8128D OctoPOPIT ModulePopit Labels DescriptionWiring OctoPOPITs Line TerminationTesting Off-board Points Address Assignment SwitchesD8128D Address Switches OctoPOPIT Sensor LoopsConnecting D8128D OctoPOPITs to the D7212G D7212G Off-board Relays Panel Relay D8129 OctoRelay D8129 OctoRelay Switch NumberD8129 OctoRelay D8129 Connections to the D7212G Command Center Terminals Assigning the command center an addressAddress Switch Arming DevicesD7212G Command Center Terminal Function Power at Command CentersKeyswitch Keyswitch Operation Maintained Contact10.3 D279A Independent Zone Control Momentary ContactD7212G Installation Printer SwitchSDI Devices 11.3 D9131A Parallel Printer Interface ModuleSDI Address Address Settings 11.5.2 D9133TTL-E Network Interface ModuleD7212G Programmer and Accessory Connections Programmer ConnectorAccessory Connector Programmer Access ReportsAccessoryProgramming ConnectorConnector Programmer and Accessory ConnectionsFaceplate 13.0 13.1 D7212G FaceplateFaceplate Appendix a System Wiring Diagrams, Issue a D7212G Control/Communicator, 1D7212G System Wiring Diagram, 2 D7212G Control/Communicator, 2D7212G System Wiring Diagram, 3 D7212G Control/Communicator, 3D7212G Appendix B Point Address Chart Zonex 1, Points 9 toD7212G Symbols IndexZonex