D7212G
On-board Points
7.5Wiring Information for Installations using the Ademco
4998138540B
LEDs Off When Normal |
|
|
|
|
|
|
|
|
|
| D7212G |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
YEL | Charging Status |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
RED Low Battery - 12.1 VDC |
|
|
|
|
|
|
| Digital Alarm Communicator Transmitter |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||
Reference D7212G Approved Applications Compliance Guide (P/N:4998138560___) |
|
|
|
|
|
|
|
|
|
| Reset Pin |
|
|
| |||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| For System Wiring Diagram, Issue A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Disable All Except Battery |
|
|
| ||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
10.2 VDC - Battery Load Shed |
|
|
|
| Reference D9000/D9000G Series Technogram (P/N:33284___) |
|
|
|
| Charging And Programming |
|
|
| ||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| For Compatible Smoke Detectors |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
| CLASS 2 TRANSFORMER |
|
|
|
|
|
|
| POWER SUPPLY REQUIREMENTS |
|
|
|
|
| PERIPHERAL DEVICE CONNECTIONS |
|
|
| |||||||||||||||||||||||||
|
|
| The Power Supply Provides a Maximum of 1.4 Amps For The Control |
|
|
|
| RED |
|
|
| POWER + |
|
|
| ||||||||||||||||||||||||||||||
|
|
| 16.5 VAC 40 VA 60 Hz |
|
|
| Panel and All Accessory Devices. For System Loading, See D7212G Operation |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||||
|
|
| Model D1640 |
|
|
|
| and Installation Guide (P/N:4998138544___). |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
| Internally Fused - Do Not short |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||
|
|
| Requires Unswitched Outlet | All External Connections Except Terminal 5 | (Battery Positive) Are Inherently Power |
|
| YELLOW |
|
| DATA BUS A |
|
|
| |||||||||||||||||||||||||||||||
|
|
| Do Not Share With Other Equipment | Limited. Requirements For Battery Standby Time May Reduce Allowable Output. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||||
|
|
| + AUX POWER |
|
|
| CAUTION: See D7212G Operation and Installation Guide (P/N:4998138544) |
|
| GREEN |
|
| DATA BUS B |
|
|
| |||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| For Power Requirements Relating to Terminals 6 | 7 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
| BATTERY NEGATIVE ONLY | WARNING! |
|
|
|
| Battery: Replace Every 3 to |
|
| BLACK |
|
|
| COMMON |
|
|
| ||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||||||||||||||||
|
|
|
| Maximum Charging | Model D122 Dual Battery Harness. | 5 years with Model D126, 12 V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||
|
|
|
| Current 1.4 Amps. | Improper Installation Can Be a Fire | 7 Amp Hr Lead Acid Battery |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||
|
|
| BATTERY POSITIVE ONLY |
|
| N.F.P.A. |
|
| ZONEX OUT 1 |
|
|
| |||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
| Hazard. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Style 3.5 |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
| PROGRAMMABLE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Signaling |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
| RELAY A |
| This equipment should be installed in accordance with the NFPA 70 (National Electrical Code) |
|
| Line |
|
|
| ZONEX IN 1 |
|
|
| ||||||||||||||||||||||||||||||
|
|
|
| ALARM OUTPUTS | and NFPA 72 (National Fire Alarm Code) Household Fire Warning Systems and under the limits of the |
|
| Circuits |
|
|
|
|
|
| |||||||||||||||||||||||||||||||
|
|
|
|
|
|
| Terminals | Local Authority Having Jurisdiction (National Fire Protection Association, Batterymarch Park, Quincy, |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||
|
|
| RELAY B | 7 | & 8 |
|
| MA 02269) Printed information describing proper installation, operation, testing, maintenance, |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||
|
|
|
| Requires Optional | evacuation planning and repair service is to be provided with this equipment. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||
|
|
|
|
|
|
| Model D136 Relay |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
| RELAY C |
| In ALT ALARM |
|
|
|
|
|
| D7212G Control/Communicator is UL Listed For Household |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
| & SW AUX |
|
| Fire Alarm, and Central Station, Local, Police Station Connect and Household Burglar Alarm. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| System is Intended To Be Checked By A Qualified Technician At Least Every 3 Years. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||
|
|
| COMMON |
|
|
|
|
|
|
| The types of initiating circuits the panel has been approved for are A, M, W, SS. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| VOLTAGE RANGES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
| EARTH GROUND |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Open |
|
| 3.7 - 5.0 VDC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Normal |
|
| 2.0 - 3.0 VDC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Short |
|
| 0.0 - 1.3 VDC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| GROUND FAULT DETECT |
|
| Point 1 Point 2 |
| Point 3 Point 4 | Point 5 Point 6 |
| Point 7 Point 8 |
| Point 8 |
|
|
|
|
|
|
| PROG |
|
|
| |||||||||||||||||||||||
|
|
|
|
|
| Enabled |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
| Disabled |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| GND FAULT |
|
|
|
|
|
|
| CONN |
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Detect |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
| GROUND START |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
| LOOP START |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| E |
|
| D |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| GND START |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| N |
|
| I |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| A |
|
| S |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| GROUND START |
| PHONE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| B |
|
| A |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
| Requires Relay |
| RED LED |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| B |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
| Model D136 in | ON WHEN | 11 | 12 13 | 14 15 16 | 17 18 19 |
| 20 |
| 21 22 |
| L |
|
| L | GRN |
|
|
|
|
|
|
|
| |||||||||||||||||
|
|
|
|
| Ground | COMMUNICATING |
|
|
| E |
|
|
|
|
|
| |||||||||||||||||||||||||||||
|
|
|
|
| Start Socket | OFF WHEN IDLE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| E |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Inner Bell
Box Lining
Outer
Bell Box
1 | 2 | 3 | 4 | 5 | 6 |
|
| B |
|
|
|
|
| e |
|
|
|
|
| l |
| EOL | |
|
| l |
| ||
|
|
|
| 220 kΩ | |
Bell | T |
| ½ W | ||
a |
|
|
| ||
|
| m |
|
|
|
|
| p |
|
|
|
|
| e |
|
|
|
|
| r |
|
|
|
|
| s |
|
|
|
Figure 12: Wiring for Installations using the Ademco AB-12 Bell/Housing
1.Disconnect the wire jumper from Terminal 4 to the inner housing of the Bell Box (prevents a ground fault condition).
2.Connect wiring between the control and Bell Box as shown above. To use the
3.Program Point 8 as
D7212G Operation and Installation Guide
4998138544C | Page 36 | © 2003 Bosch Security Systems |