Installation
Releasing the reset pin from the closed position resets the panel. The panel resets all its timers, counters, indexes, and buffers. Any points that restore after a reset is performed will not generate restoral reports.
If the reset pin is placed in the disable position when all areas are armed, there must be an entry in the Answer Armed program item. See RAM Parameters in the D7212G Program Entry Guide (P/N: 4998138538).
Locking the pin in the disable position allows powering up the panel and charging the battery while the detection devices and command centers are being installed.
3.6Finishing the Installation
Earth ground and reset pin first: Make the earth ground connection to Terminal 10 and lock the reset pin in the closed position if not already done.
3.6.1Charge the Battery While Finishing
Connect the battery and then the transformer so that the panel can charge the battery while the installation is being finished. See Section 4.0 Power Supply, on page 25 for instructions.
If the panel fails any of the tests, the buzzer continues sounding and a system trouble message appears at the command centers. See Problems Found During Self Diagnostics in the D9412G/D7412G/D7212G Installation and Troubleshooting Quick Reference Guide (P/N: 43700) for a description of each system trouble message.
Touch Terminal 10 first: If the
3.6.2Install and Wire Detection Devices
Install and wire detection devices and command centers at their locations throughout the premises. DO NOT make the connections at the panel end of the wiring yet.
Section 7.0
Instructions for wiring the
3.6.3Install Modules and Relays
1.Power Down First: Power down the unit by unplugging the transformer and disconnecting the battery. Bosch Security Systems recommends powering down the unit when installing modules or relays, or when making wiring connections to the panel.
2.Install and wire any modules required for the installation as described in the module’s installation instructions.
Instructions for the D8125 POPEX Module, the D8128D OctoPOPIT Module, and the D8129 OctoRelay Module appear in this guide.
See Section 8.0
3.If using the power outputs at Terminals 7 or 8, install a D136 relay in the appropriate sockets. See Section 5.4 Programmable Power Outputs Terminals on page 29 for instructions.
4.If using a ground start phone system, insert a D136 relay in the ground start check socket and set the ground start pin in the ground start position. See Section 6.11 Ground Start on page 33 for more information.
D7212G Operation and Installation Guide
© 2003 Bosch Security Systems | Page 23 | 4998138544C |