SVAT Electronics CLEARVU11 Setup- Click on this icon to call up Setup dialog, Memory Dram 512MB

Page 54

NETWORKING GUIDE

SVAT ELECTRONICS

now you can see

14.- Click on this icon to call up search-PC-video dialog. Please select the file, and then click on Open. Now, you may use the playback buttons to play the recorded video/audio in the file.

15.- Click on this icon to show/hide full PTZ control panel. The user can click on the PTZ Panel (but outside of any object in it) (to call up the Context menu) to move it.

16. Setup- Click on this icon to call up Setup dialog.

17.- Click on this icon to call up remote Software Upgrade dialog. Please select the DVR device and upgrade file in the PC, and then click on Start button to start the software upgrade process. The Upgrade status will be updated according to the progress. When the upgrade file is uploading, the user may click on Stop/Close button to stop the upgrade process. After the software in the DVR is upgraded, the DVR will restart immediately and the PC will be disconnected from the DVR.

NOTE : There must be at least one formatted HDD in the DVR for the remote upgrade to succeed.

Following is a brief description for each item:

Device Name – any meaningful name for the (DVR) device.

Address – IP address or URL domain name for the (DVR) device. It should be the same as the IP address (for Static IP) or URL (for PPPoE) in Network Setup for the (DVR) device.

Control Port – the control port for the (DVR) device. The default value is 67.

Data Port – the data port for the (DVR) device. The default value is 68.

User Name – the login user name for the (DVR) device. It must be in the list in Password Setup for the (DVR) device.

Please note that different levels of users have different available operations.

Password – the corresponding password for the login user name for the (DVR) device.

Auto Connection – whether the user wants to connect automatically to this (DVR) device.

Connected – whether this PC is connected with the (DVR) device now.

System Requirements of Remote PC

It is recommended to access the digital video/audio recorder using a PC that meets the following system requirements. If you use a PC that does not meet the following system requirements, it may cause problems such as slow imaging or the browser unable to operate.

PC - IBM PC/AT compatible.

CPU - Intel® Pentium® 4, 1.4 GHz or above.

OS - MicroSoft® Windows® XP or Windows® 2000 with SP4.

Monitor - 1024 x 768 or above.

Memory (DRAM) - 512MB.

Network Interface - Ethernet, 10/100 Base-T.

Web Browser - MicroSoft® Internet Explorer® 6.0 or above.

DirectX - MicroSoft® DirectX® 9.0 or above.

CLEARVU11

51

 

 

Image 54
Contents 4CH 15 LCD-DVR All-In-One System VersionIMPORTANT! Please Read Do not Return this Product to the StoreProduct Warranty Information Table of Contents HDD FORMAT/CLEAR For DVR Power CablesIntroduction 10ft RJ-45 Cable Software CDButton Functions and Connections Monitor Speaker Remote Control Infrared IR SensorPower Cord Inlet Power in For DC-IN Hard Drive CoverBasic Setup Alpa/Numeric keysAdjust cameras to the desired viewing angles Mounting the CameraPowering the System General Information Main ScreeenGeneral Information Press to move the cursor to the left/rightMenu Used to call up the full menu Stop Stops using playback modeVolume Turns muting on or off Search Used to call up the search optionsPTZ Setup Using the Mouse Common IconsMain Menu ALPHA-NUMERIC KeyboardPress these buttons to change the highlighted item Enter Press Enter to login the system Enter+/-Press these buttons to adjust the selected item Press these buttons to select the itemsMain Menu PRE-CAMERA Setup Camera Setup TitleCopy Motion Detection Main Menu Covert Call by EventDwell Time AudioRecord Quality and Record IPS Alarm Setup Focus Camera the camera corresponding to this alarm inputSEQ Display Setup Following is a brief description of the operations Scheduled Record Setup HDD Setup Main Menu Mode Format SEQ ClearCall Physical Format Password Setup System Setup System TimeRS-232/422/485 Setup Network Setup Use the keys to navigate over to E-mail or AdvMail Setup Advanced Network Setup Software Upgrade Administrator mode only Factory DefualtsConnecting Your DVR to the Router Genuine and fully updated version of Windows XP or VistaNetworking Guide Finding the DVR’S IP Address Press ESC to exit out of Menu. Press Enter to save changesPreparing Your Computer for Viewing the DVR Method 1 RecommendedViewing Your DVR on Your Computer MethodNetworking Guide Once YOU are on PORTFORWARD.COM Connecting the DVR Using a D-LINK Router Example Select the Advanced tabFinding Your External IP Address Reason to change the DVR to another port not recommendedSchedule field, select Always Click Apply Enter your preferred user name, email address, and password Dynamic DNSNetworking Guide Select Setup Select Network DSL modem is preventing a connectionRemote Viewing Search by Time CameraFocus window Search by EventSetup- Click on this icon to call up Setup dialog System Requirements of Remote PCMemory Dram 512MB Search Menu Search by TimePlayback/Archive For Search By Time Search Menu Search by Event Search Archived Files Playback/Archive For Search By EventPDA/Mobile Phone Remote Access Playback For Archived FilesHEM Player Keyboard Control Simulator Information Sheet M4V/H.264 to AVI Conversion UtilityWhen playing back Troubleshooting GuideSaved in login MouseDVR SettingsVGA Options is not EtcSet time Remote control is notWorking IPS to 30 IPSManual TextComputer White CamerasMy camera is not Electrical noiseSpecifications Network AlarmSetup ControlBattery Operable Viewing Angle PowerResolution ConnectorTV System AutoCLEARVU11 Product Information Quick Start Guides