 DETERMINING THE LOCATION FOR DV1000

Manual background DETERMINING THE LOCATION FOR DV1000

Note: The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Instal- lation Code, CSA B149.1.

This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appli- ance is not convertible for use with other gases, unless a certified kit is used.

Due to high temperatures, the appliance should be located out of traffic and away from fur- niture and draperies.

The appliance, when installed, must be electrically grounded in accordance with local codes or, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code CSA C22.1.

The Model DV1000 Direct Vent Fireplace must be vented using only Magnaflex DV4-F venting system. All warranties will be voided and tech service suspended and serious fire, health or safety hazards may result from using any other venting system than the tested and approved Magnaflex DV4-F system with this appliance.

You must check the Vent Termination Clearance requirements from decks, windows, soffits, gas regulators, air supply inlets, and public walkways, etc. as shown in these instructions and speci- fied by local building codes (see figure 4, page 7). This gas appliance must be vented directly to the outside of the building. This gas appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance. Preparation for electrical connection and gas supply must be made before the appliance is located. (see figure 3, page 6 for framing dimensions)

MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL FROM FIREPLACE AND VENT SURFACES:

Sides, Back, Bottom and Top of appliance (standoffs)

0 inch

Recessed depth to back of front trim

17 inches

Recessed depth to front of front trim

17-1/2 inches

Diameter of vent pipe

2

inches

Top of appliance to ceiling

54

inches

MANTEL CLEARANCES……

DRYWALL

W=Width (@) H=Height

 

WALL BOARD

3/4” ——————–2”

 

2”———————–2”

 

 

NOTE: Adequate clear-

W

4”———————–10”

 

 

STUD

6”———————–12”

ances around air openings

 

8”———————–14”

 

into the combustion cham-

H

10”———————16”

ber. Do Not cover any of

STANDOFF

12”———————18”

the louvered areas on this

 

 

 

TOP EDGE OF

appliance front, or the glass

 

cover door.

 

UNITS TRIM

DV1000

FIGURE 5

 

Page 8

Image 11
Contents Approved By DV1000ZERO CLEARANCE DIRECT VENT GAS FIREPLACE Page TABLE OF CONTENTS Page INSTALLATION AND OPERATION INTRODUCTION AND SAFETY FORDV1000 FIREBOX COVER DOOR REMOVAL INSTRUCTIONS VER ASSEMBLY CLIP TO SECURE TO STOVE BODY 1. TOP LOUVER ASSEMBLY2. BOTTOM LOUVER ASSEMBLY LOUVER ASSEMBLYTOP STANDOFFS SIDE STANDOFFS 27-1/8” 13-9/16” DV1000 SPECIFICATIONS38-1/8” 36” 33-1/2” 16-15/16” 2-1/2” 6”36-1/8 MINIMUM FRAMING DIMENSIONS40-1/8” 2-1/2”Page VENT TERMINAL CLEARANCESDETERMINING THE LOCATION FOR DV1000 DV1000 DIRECT VENT TERMINATION INSTALLATION INSTRUCTIONSPIPE INSTALLATION PRE-INSTALLATIONINFORMATIONOUTER 7” VENT PIPE INNER 4” FLUE PIPE MINATION EXAMPLE CORNER TERMINATION WITH OPTIONAL REAR VENTFIGURE 8/ OPTIONAL REAR VENT TER 9-1/2”WALLMAXIMUM INSTALLATION MINIMUM INSTALLATION30FT MAX INSTALLATIONSVERTICAL TERMINATION CAP ASSEMBLY DV1000 STANDARD VERTICAL CHASE TERMINATIONREMOVABLE INNER BOTTOM PAN ASSEMBLY CHECK GAS TYPE INSTALLING GAS PIPING TO APPLIANCEInstallation Items Needed GAS SUPPLY CONNECTIONTest Pressures In Excess of 1/2 PSIG 3.5 kPa Pressure Testing Gas Supply Piping Systemance of the heater DV1000 LOG PLACEMENTWARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury WHAT TO DO IF YOU SMELL GAS FOR YOUR SAFETY READ BEFORE LIGHTINGLIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE WIRING DIAGRAM REPAIR PARTS SERVICINGCLEANING AND MAINTENANCE EMBERS BURNER PAN ASSEMBLYVENTURA ASSEMBLY Air Shutter Slot Opening LOGSREMEDY TROUBLESHOOTINGOBSERVED PROBLEM POSSIBLE CAUSEBurner does not light after pilot is lit Diagram, pageGas leak. See Warning statement TROUBLESHOOTINGMaintenance, page ContinuedPART DESCRIPTION REPLACEMENT PARTSSERVICING KEY#Page ON/OFF/MANUALADDITIONAL REPLACEMENT PARTS CONDITIONS AND EXCLUSIONS WARRANTYWARRANTY PROCEDUREOTHER RIGHTS Page