INTRODUCTION AND SAFETY FOR

INTRODUCTION AND SAFETY FOR

INSTALLATION AND OPERATION

This instruction manual will help you obtain a safe, efficient, dependable installation for your appliance and vent system. Please read and understand these instructions before beginning your installation.

The model DV1000 is a sealed combustion, air circulating gas appliance designed for residential and mobile home applications. The appliance must be installed with Magnaflex DV4-F vent system that is routed to outside atmosphere. It is also listed for bedroom installations.

This appliance is designed to operate on natural or propane gas. A millivolt gas control valve with piezo ignition system provides safe, efficient operation. No external electrical power is required to operate the gas valve and burner. 115V AC is required to operate the room air fan.

This appliance complies with National Safety Standards and is tested and listed to ANSI Z21.88-2005 and CSA 2.33-2005.

Installation must conform to local codes. In the absence of local codes, installation must comply with

the current National Fuel Gas Code, ANSI Z223.1/NFPA54, or the National gas and Propane Installation Code, CSA b149.1...

SPECIFICATIONS - MODEL DV1000

 

RATE:

NAT.

L.P.

MAX.

25,000 BTU

24,000 BTU

MIN.

20,000 BTU

20,000 BTU

GAS SUPPLY PRESSURE:

NAT.

L.P.

MAX. INPUT

10.5" W.C.

13.0" W.C.

MIN. INPUT

*4.0" W.C.

11." W.C.

MANIFOLD PRESSURE:

NAT.

L.P.

 

3.5" W.C.

10.0" W.C.

EFFICIENCY:(With Blower “ON”)

 

 

NATURAL GAS

88%

 

L.P. GAS

88%

FLUE VENT

4" INNER, 7" OUTER; Magnaflex

SAFETY

CSA CERTIFIED PILOT GENERATOR, MILLIVOLT

 

SYSTEM ACTIVATED WITH SWITCH OR THERMOSTAT.

Page 2

Image 5
Contents Approved By DV1000ZERO CLEARANCE DIRECT VENT GAS FIREPLACE Page TABLE OF CONTENTS Page INSTALLATION AND OPERATION INTRODUCTION AND SAFETY FORDV1000 FIREBOX COVER DOOR REMOVAL INSTRUCTIONS 2. BOTTOM LOUVER ASSEMBLY 1. TOP LOUVER ASSEMBLYLOUVER ASSEMBLY VER ASSEMBLY CLIP TO SECURE TO STOVE BODY38-1/8” 36” 33-1/2” DV1000 SPECIFICATIONS16-15/16” 2-1/2” 6” TOP STANDOFFS SIDE STANDOFFS 27-1/8” 13-9/16”40-1/8” MINIMUM FRAMING DIMENSIONS2-1/2” 36-1/8Page VENT TERMINAL CLEARANCESDETERMINING THE LOCATION FOR DV1000 DV1000 DIRECT VENT TERMINATION INSTALLATION INSTRUCTIONSPIPE INSTALLATION PRE-INSTALLATIONINFORMATIONOUTER 7” VENT PIPE INNER 4” FLUE PIPE FIGURE 8/ OPTIONAL REAR VENT TER CORNER TERMINATION WITH OPTIONAL REAR VENT9-1/2”WALL MINATION EXAMPLEMAXIMUM INSTALLATION MINIMUM INSTALLATIONVERTICAL TERMINATION CAP ASSEMBLY INSTALLATIONSDV1000 STANDARD VERTICAL CHASE TERMINATION 30FT MAXREMOVABLE INNER BOTTOM PAN ASSEMBLY Installation Items Needed INSTALLING GAS PIPING TO APPLIANCEGAS SUPPLY CONNECTION CHECK GAS TYPETest Pressures In Excess of 1/2 PSIG 3.5 kPa Pressure Testing Gas Supply Piping Systemance of the heater DV1000 LOG PLACEMENTWARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury WHAT TO DO IF YOU SMELL GAS FOR YOUR SAFETY READ BEFORE LIGHTINGLIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE WIRING DIAGRAM REPAIR PARTS SERVICINGCLEANING AND MAINTENANCE VENTURA ASSEMBLY Air Shutter Slot Opening BURNER PAN ASSEMBLYLOGS EMBERSOBSERVED PROBLEM TROUBLESHOOTINGPOSSIBLE CAUSE REMEDYBurner does not light after pilot is lit Diagram, pageMaintenance, page TROUBLESHOOTINGContinued Gas leak. See Warning statementSERVICING REPLACEMENT PARTSKEY# PART DESCRIPTIONPage ON/OFF/MANUALADDITIONAL REPLACEMENT PARTS WARRANTY WARRANTYPROCEDURE CONDITIONS AND EXCLUSIONSOTHER RIGHTS Page