New Buck Corporation DV1000 manual Top Louver Assembly, Firebox Cover Door, Bottom Louver Assembly

Page 7
1. TOP LOUVER ASSEMBLY

1.The top louver assembly must be removed first. To remove the top louver assembly you must place your hands one at the bottom left corner and the other at the bottom right corner of the lou- ver assembly. Then with both hands lift up and outwards to release the louver clips from the stove body. After removing the louver assembly place it in a safe place until time to reinstall.

2.The bottom louver assembly must be in the open position to access the firebox cover door fas- teners. The bottom louver assembly is hinged to the bottom of the stove. Place one hand on the center of the top louver and pull slowly out and downward to open.

3.Before removing the firebox cover door you must remove the six (6) 1/4-20 nuts located across the top of the door and the bottom of the door. After removing the nuts you must slowly pull the door outward and completely off the studs. Place the door in a safe place until time to reinstall, the glass is breakable.

NOTE: The Firebox Cover Door must be removed to access the pilot assembly located in the right rear corner of the firebox area, and to access the burner pan located in the bottom center of the firebox area. The door must also be removed when placing the logs and embers.

4. To replace the cover door, reverse steps 3 thru 2.

1. TOP LOUVER ASSEMBLY

 

3. FIREBOX COVER DOOR

 

2. BOTTOM LOUVER ASSEMBLY

 

FIGURE 1

RIGHT SIDE

LEFT SIDE

 

FRONT

 

#1 SIDE VIEW OF

#1

LOUVER ASSEMBLY

AND CLIP.

 

SLOT IN STOVE BODY FRONT FOR LOU-

VER ASSEMBLY CLIP TO SECURE TO

STOVE BODY.

1/4-20 NUTS

#3

#2

Replace the entire cover door assembly if glass becomes defective with part # PO COVDOR1.

Page 4

Image 7
Contents ZERO CLEARANCE DIRECT VENT GAS FIREPLACE DV1000Approved By Page TABLE OF CONTENTS Page INSTALLATION AND OPERATION INTRODUCTION AND SAFETY FORDV1000 FIREBOX COVER DOOR REMOVAL INSTRUCTIONS VER ASSEMBLY CLIP TO SECURE TO STOVE BODY 1. TOP LOUVER ASSEMBLY2. BOTTOM LOUVER ASSEMBLY LOUVER ASSEMBLYTOP STANDOFFS SIDE STANDOFFS 27-1/8” 13-9/16” DV1000 SPECIFICATIONS38-1/8” 36” 33-1/2” 16-15/16” 2-1/2” 6”36-1/8 MINIMUM FRAMING DIMENSIONS40-1/8” 2-1/2”Page VENT TERMINAL CLEARANCESDETERMINING THE LOCATION FOR DV1000 DV1000 DIRECT VENT TERMINATION INSTALLATION INSTRUCTIONSPIPE INSTALLATION PRE-INSTALLATIONINFORMATIONOUTER 7” VENT PIPE INNER 4” FLUE PIPE MINATION EXAMPLE CORNER TERMINATION WITH OPTIONAL REAR VENTFIGURE 8/ OPTIONAL REAR VENT TER 9-1/2”WALLMAXIMUM INSTALLATION MINIMUM INSTALLATION30FT MAX INSTALLATIONSVERTICAL TERMINATION CAP ASSEMBLY DV1000 STANDARD VERTICAL CHASE TERMINATIONREMOVABLE INNER BOTTOM PAN ASSEMBLY CHECK GAS TYPE INSTALLING GAS PIPING TO APPLIANCEInstallation Items Needed GAS SUPPLY CONNECTIONTest Pressures In Excess of 1/2 PSIG 3.5 kPa Pressure Testing Gas Supply Piping Systemance of the heater DV1000 LOG PLACEMENTWARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury WHAT TO DO IF YOU SMELL GAS FOR YOUR SAFETY READ BEFORE LIGHTINGLIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE WIRING DIAGRAM REPAIR PARTS SERVICINGCLEANING AND MAINTENANCE EMBERS BURNER PAN ASSEMBLYVENTURA ASSEMBLY Air Shutter Slot Opening LOGSREMEDY TROUBLESHOOTINGOBSERVED PROBLEM POSSIBLE CAUSEBurner does not light after pilot is lit Diagram, pageGas leak. See Warning statement TROUBLESHOOTINGMaintenance, page ContinuedPART DESCRIPTION REPLACEMENT PARTSSERVICING KEY#Page ON/OFF/MANUALADDITIONAL REPLACEMENT PARTS CONDITIONS AND EXCLUSIONS WARRANTYWARRANTY PROCEDUREOTHER RIGHTS Page