TROUBLESHOOTING
Note: All troubleshooting items are listed in order of operation.
| OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY |
| ||
|
|
|
|
|
|
|
| When ignitor button is pressed, there is no | 1. | Ignitor electrode not connected to | 1. | Reconnect ignitor cable |
|
| spark at pilot |
| ignitor cable |
|
|
|
|
| 2. | Ignitor cable pinched or wet | 2. | Free ignitor cable if pinched by any |
|
|
|
|
|
| metal or tubing. Keep ignitor cable |
|
|
| 3. | Piezo ignitor nut is loose |
| dry |
|
|
| 3. | Tighten nut holding piezo ignitor. |
| ||
|
|
|
|
| Nut is located behind the mounting |
|
|
| 4. | Broken ignitor cable |
| bracket |
|
|
| 4. | Replace ignitor cable |
| ||
|
| 5. | Bad piezo ignitor | 5. | Replace piezo ignitor |
|
|
| 6. | Ignitor electrode broken | 6. | Replace pilot assembly |
|
|
| 7. | Ignitor electrode positioned wrong | 7. | Replace pilot assembly |
|
|
|
|
|
|
|
|
| When ignitor button is pressed, there is | 1. | Gas supply turned off or equipment | 1. | Turn on gas supply or open |
|
| spark at pilot but no ignition |
| shutoff valve closed |
| equipment shutoff valve |
|
|
| 2. | Gas control knob not in PILOT | 2. | Turn gas control knob to PILOT |
|
|
|
| position |
| position |
|
|
| 3. | Gas control knob not pressed in | 3. | Press in gas control knob while in |
|
|
|
| while in PILOT position |
| PILOT position |
|
|
| 4. | Air in gas lines when installed | 4. | Continue holding down gas control |
|
|
|
|
|
| knob. Repeat igniting operation until |
|
|
| 5. | Depleted gas supply (propane/LP |
| air is removed |
|
|
| 5. | Contact local propane/LP gas |
| ||
|
|
| models only) |
| company |
|
|
| 6. | Pilot is clogged | 6. | Clean pilot (see Cleaning and |
|
|
|
|
|
| Maintenance, page 25 or replace |
|
|
| 7. | Gas regulator setting is not correct |
| pilot assembly |
|
|
| 7. | Replace gas control |
| ||
|
|
|
|
|
|
|
| Pilot lights but flame goes out when | 1. | Gas control knob not fully pressed in | 1. | Press in gas control knob fully |
|
| control knob is released | 2. | Gas control knob not pressed in long | 2. | After pilot lights, keep gas control |
|
|
|
| enough |
| knob pressed in 30 seconds |
|
|
| 3. | Equipment shutoff valve not fully | 3. | Fully open equipment shutoff valve |
|
|
|
| open |
|
|
|
|
| 4. | Pilot flame not touching | 4. | A) Contact local gas company |
|
|
|
| thermocouple, which allows |
|
|
|
|
|
| thermocouple to cool, causing pilot |
|
|
|
|
|
| flame to go out. This problem could |
|
|
|
|
|
| be caused by one or both of the |
| B) Clean pilot (see Cleaning and |
|
|
|
| following: |
| Maintenance, page 25) or replace |
|
|
|
| A. Low gas pressure |
| pilot assembly |
|
|
|
| B. Dirty or partially clogged pilot |
|
|
|
|
| 5. | Thermocouple connection loose at | 5. | Hand tighten until snug, then tighten |
|
|
|
| control valve |
| 1/4 turn more |
|
|
| 6. | Thermocouple damaged | 6. | Replace thermocouple |
|
|
| 7. | Control valve damaged | 7. | Replace control valve |
|
|
|
| 24 |
|
|
|