New Buck Corporation DV1000 manual Minimum Installation, Maximum Installation

Page 16
MINIMUM INSTALLATION

DV1000 STANDARD HORIZONTAL TERMINATION INSTALLATIONS

HORIZONTAL

TERMINATION CAP

ASSEMBLY

12”

45-1/2”

10-1/2” From Rear

Standoff To Outside

Wall.

MINIMUM INSTALLATION

53” Max. & 11” Min.

From Rear Standoff To

Outside Wall.

NOTE: Horizontal pipe installations must be supported with Wall Straps every 3 feet.

WALL STRAPS

56”Max. & 49-1/2” Min.

 

*16”

 

 

 

 

 

 

 

 

 

 

 

MAXIMUM INSTALLATION

FIGURE 10

Page 13

Image 16
Contents ZERO CLEARANCE DIRECT VENT GAS FIREPLACE DV1000Approved By Page TABLE OF CONTENTS Page INTRODUCTION AND SAFETY FOR INSTALLATION AND OPERATIONDV1000 FIREBOX COVER DOOR REMOVAL INSTRUCTIONS 1. TOP LOUVER ASSEMBLY 2. BOTTOM LOUVER ASSEMBLYLOUVER ASSEMBLY VER ASSEMBLY CLIP TO SECURE TO STOVE BODYDV1000 SPECIFICATIONS 38-1/8” 36” 33-1/2”16-15/16” 2-1/2” 6” TOP STANDOFFS SIDE STANDOFFS 27-1/8” 13-9/16”MINIMUM FRAMING DIMENSIONS 40-1/8”2-1/2” 36-1/8VENT TERMINAL CLEARANCES PageDETERMINING THE LOCATION FOR DV1000 INSTALLATION INSTRUCTIONS DV1000 DIRECT VENT TERMINATIONPRE-INSTALLATIONINFORMATION PIPE INSTALLATIONOUTER 7” VENT PIPE INNER 4” FLUE PIPE CORNER TERMINATION WITH OPTIONAL REAR VENT FIGURE 8/ OPTIONAL REAR VENT TER9-1/2”WALL MINATION EXAMPLEMINIMUM INSTALLATION MAXIMUM INSTALLATIONINSTALLATIONS VERTICAL TERMINATION CAP ASSEMBLYDV1000 STANDARD VERTICAL CHASE TERMINATION 30FT MAXREMOVABLE INNER BOTTOM PAN ASSEMBLY INSTALLING GAS PIPING TO APPLIANCE Installation Items NeededGAS SUPPLY CONNECTION CHECK GAS TYPEPressure Testing Gas Supply Piping System Test Pressures In Excess of 1/2 PSIG 3.5 kPaDV1000 LOG PLACEMENT ance of the heaterWARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury FOR YOUR SAFETY READ BEFORE LIGHTING WHAT TO DO IF YOU SMELL GASLIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE WIRING DIAGRAM SERVICING REPAIR PARTSCLEANING AND MAINTENANCE BURNER PAN ASSEMBLY VENTURA ASSEMBLY Air Shutter Slot OpeningLOGS EMBERSTROUBLESHOOTING OBSERVED PROBLEMPOSSIBLE CAUSE REMEDYDiagram, page Burner does not light after pilot is litTROUBLESHOOTING Maintenance, pageContinued Gas leak. See Warning statementREPLACEMENT PARTS SERVICINGKEY# PART DESCRIPTIONON/OFF/MANUAL PageADDITIONAL REPLACEMENT PARTS WARRANTY WARRANTYPROCEDURE CONDITIONS AND EXCLUSIONSOTHER RIGHTS Page