New Buck Corporation manual DV1000 LOG PLACEMENT, ance of the heater

Page 21
DV1000 LOG PLACEMENT

CAUTION

Hot while in operation. Do Not Touch severe burns may result. Keep children, clothing, furniture, gasoline, and other liquids having flammable vapors away.

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury, or loss of life. Refer to owner’s information manual provided with this appliance. Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

IMPORTANT: Always operate the appliance at the completely ON or the completely OFF positions. Never use the heater at a setting between these positions as this can result in improper combustion and excessive carbon monoxide emissions.

Keep burner and control compartment clean. See installation and operating instructions accompanying heater.

DV1000 LOG PLACEMENT

Before placing the Logs and Embers you must first remove the Firebox Cover Door from the appliance, see pages 3 and 4. After removing the cover door follow the instructions below and on the following page. (The log placement is exactly the same for the Pine log set as for the Oak log set.

1.Carefully open the box containing the logs. Remove the #1 log (Rear Log) and place it in the rear center of the firebox behind the log holders located on the left and right sides.

2.Next remove the #2 log (Left Middle Log) and place it on the 2 pins (screws) located on the left hand side of the burner.

3.Now remove the #3 log (Right Middle Log) and place it on the pins (screws) located on the right hand side of the burner.

4.Locate the #4 log (Left Front Log) and place it on the pin (screw) located on the left front bottom corner of the firebox. Next place the other end of the log on the pin (pins) located on the left side of the top of the #1 log.

5.Place the large end of the #5 log (Front Center Log) on the pin (screw) located in the front bottom center of the firebox. Place the other end of the #5 log on the pin located at the top center of the #1 log.

6.Next place the #6 log (Right Front Bottom Log) on the pins (screws) located on the left hand side of the bottom of the firebox.

7.Place the #7 log (Right Front Top Log) on to the pins located in the top of the #6 log.

8.Provided with your log set is a package of Glowing Embers (rock wool). Open the package and tare off small pieces of the wool material and place it over the small holes (ports) lo- cated on the front burner pan in front of logs #5 and #6. Cover the entire section of holes (ports). *Replacement of loose (Glowing Embers) must be purchased from the original manufacturer and application of excess loose material may adversely affect perform-

ance of the heater.

NOTE: “Wash your hands immediately after coming in contact with the wool material. The wool can cause slight itching or burning in some cases, avoid any contact with eyes.”

Page 18

Image 21
Contents DV1000 ZERO CLEARANCE DIRECT VENT GAS FIREPLACEApproved By Page TABLE OF CONTENTS Page INSTALLATION AND OPERATION INTRODUCTION AND SAFETY FORDV1000 FIREBOX COVER DOOR REMOVAL INSTRUCTIONS 2. BOTTOM LOUVER ASSEMBLY 1. TOP LOUVER ASSEMBLYLOUVER ASSEMBLY VER ASSEMBLY CLIP TO SECURE TO STOVE BODY38-1/8” 36” 33-1/2” DV1000 SPECIFICATIONS16-15/16” 2-1/2” 6” TOP STANDOFFS SIDE STANDOFFS 27-1/8” 13-9/16”40-1/8” MINIMUM FRAMING DIMENSIONS2-1/2” 36-1/8Page VENT TERMINAL CLEARANCESDETERMINING THE LOCATION FOR DV1000 DV1000 DIRECT VENT TERMINATION INSTALLATION INSTRUCTIONSPIPE INSTALLATION PRE-INSTALLATIONINFORMATIONOUTER 7” VENT PIPE INNER 4” FLUE PIPE FIGURE 8/ OPTIONAL REAR VENT TER CORNER TERMINATION WITH OPTIONAL REAR VENT9-1/2”WALL MINATION EXAMPLEMAXIMUM INSTALLATION MINIMUM INSTALLATIONVERTICAL TERMINATION CAP ASSEMBLY INSTALLATIONSDV1000 STANDARD VERTICAL CHASE TERMINATION 30FT MAXREMOVABLE INNER BOTTOM PAN ASSEMBLY Installation Items Needed INSTALLING GAS PIPING TO APPLIANCEGAS SUPPLY CONNECTION CHECK GAS TYPETest Pressures In Excess of 1/2 PSIG 3.5 kPa Pressure Testing Gas Supply Piping Systemance of the heater DV1000 LOG PLACEMENTWARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury WHAT TO DO IF YOU SMELL GAS FOR YOUR SAFETY READ BEFORE LIGHTINGLIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE WIRING DIAGRAM REPAIR PARTS SERVICINGCLEANING AND MAINTENANCE VENTURA ASSEMBLY Air Shutter Slot Opening BURNER PAN ASSEMBLYLOGS EMBERSOBSERVED PROBLEM TROUBLESHOOTINGPOSSIBLE CAUSE REMEDYBurner does not light after pilot is lit Diagram, pageMaintenance, page TROUBLESHOOTINGContinued Gas leak. See Warning statementSERVICING REPLACEMENT PARTSKEY# PART DESCRIPTIONPage ON/OFF/MANUALADDITIONAL REPLACEMENT PARTS WARRANTY WARRANTYPROCEDURE CONDITIONS AND EXCLUSIONSOTHER RIGHTS Page