GAS SUPPLY CONNECTION

GAS SUPPLY CONNECTION

CHECK GAS TYPE

Use proper gas type for the burner system you are installing. If you have conflicting gas types, do not install burner system. See dealer where you purchased the stove and burner system for proper burner system according to your gas type.

INSTALLING GAS PIPING TO APPLIANCE

Installation Items Needed

Before installing the appliance make sure you have the items listed below.

External regulator (supplied by installer)

Piping (check local codes)

Sealant (resistant to propane/LP gas)

Equipment shutoff valve *

Test gauge connection *

Sediment trap

Tee joint

Pipe wrench

An CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the CSA design-certified equipment shutoff valve from your dealer.

CAUTION: For propane/LP units, never connect burner system directly to the propane/LP supply. This burner system requires an external regulator (not supplied). Install the external regulator between the burner system and propane/LP supply.

CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to burner system. If pipe is too small, undue loss of pressure will occur.

For propane/LP connections only, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, burner system regulator damage could occur. Install external regulator with the vent pointing down as shown in. Pointing the vent down protects it from freezing rain or sleet.

Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from burner system. IMPORTANT: Install main gas valve (equipment shutoff valve) in an accessible location. The main gas valve is for turning on or shutting off the gas to the appliance.

Check your building codes for any special requirements for locating equipment shutoff valve to stoves.

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged burner system valves.

We recommend that you install a sediment trap/drip leg in supply line. Locate sediment trap/drip leg where it is within reach for cleaning. Install in piping system between fuel supply and burner system. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into burner system gas controls. If sediment trap/drip leg is not installed or is installed wrong, burner system may not run properly.

Page 16

Image 19
Contents ZERO CLEARANCE DIRECT VENT GAS FIREPLACE DV1000Approved By Page TABLE OF CONTENTS Page INSTALLATION AND OPERATION INTRODUCTION AND SAFETY FORDV1000 FIREBOX COVER DOOR REMOVAL INSTRUCTIONS VER ASSEMBLY CLIP TO SECURE TO STOVE BODY 1. TOP LOUVER ASSEMBLY2. BOTTOM LOUVER ASSEMBLY LOUVER ASSEMBLYTOP STANDOFFS SIDE STANDOFFS 27-1/8” 13-9/16” DV1000 SPECIFICATIONS38-1/8” 36” 33-1/2” 16-15/16” 2-1/2” 6”36-1/8 MINIMUM FRAMING DIMENSIONS40-1/8” 2-1/2”Page VENT TERMINAL CLEARANCESDETERMINING THE LOCATION FOR DV1000 DV1000 DIRECT VENT TERMINATION INSTALLATION INSTRUCTIONSPIPE INSTALLATION PRE-INSTALLATIONINFORMATIONOUTER 7” VENT PIPE INNER 4” FLUE PIPE MINATION EXAMPLE CORNER TERMINATION WITH OPTIONAL REAR VENTFIGURE 8/ OPTIONAL REAR VENT TER 9-1/2”WALLMAXIMUM INSTALLATION MINIMUM INSTALLATION30FT MAX INSTALLATIONSVERTICAL TERMINATION CAP ASSEMBLY DV1000 STANDARD VERTICAL CHASE TERMINATIONREMOVABLE INNER BOTTOM PAN ASSEMBLY CHECK GAS TYPE INSTALLING GAS PIPING TO APPLIANCEInstallation Items Needed GAS SUPPLY CONNECTIONTest Pressures In Excess of 1/2 PSIG 3.5 kPa Pressure Testing Gas Supply Piping Systemance of the heater DV1000 LOG PLACEMENTWARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury WHAT TO DO IF YOU SMELL GAS FOR YOUR SAFETY READ BEFORE LIGHTINGLIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE WIRING DIAGRAM REPAIR PARTS SERVICINGCLEANING AND MAINTENANCE EMBERS BURNER PAN ASSEMBLYVENTURA ASSEMBLY Air Shutter Slot Opening LOGSREMEDY TROUBLESHOOTINGOBSERVED PROBLEM POSSIBLE CAUSEBurner does not light after pilot is lit Diagram, pageGas leak. See Warning statement TROUBLESHOOTINGMaintenance, page ContinuedPART DESCRIPTION REPLACEMENT PARTSSERVICING KEY#Page ON/OFF/MANUALADDITIONAL REPLACEMENT PARTS CONDITIONS AND EXCLUSIONS WARRANTYWARRANTY PROCEDUREOTHER RIGHTS Page