HOW TO LOCATE CHIMNEY EXIT, AND INSTALL
Residential and Mobile Home Installation.
D. Vertical Wall Exit using (6" DVL Close Clearance Pipe, and Elbow, and any Listed 2100° UL HT chimney and Listed 2100° UL HT T-Box assembly).
Without optional close clearance shield and pipe shield NOTE: For minimum clearances (See Page 21, Figure 13).
1.Mark the plumb line on the wall directly behind the center of the heater. (See Page 21, Figure 14.)
NOTE: When using DVL Close Clearance Pipe , “maintain manufacturer’s minimum clearances" between pipe and ceiling.
2.Place the vertical portion of the heater pipe and the elbow in position and project a point onto the plumb line level with the center of the elbow.
3.Measure up so there will be at least 1/4" rise per foot of horizontal connector pipe, maintaining clearances to the ceiling as noted in (Page 21,Figure 14). This will give you the center of the hole for the chimney penetration.
4.After locating the center of the penetration, install the
5.Connect the DVL close clearance pipe to the
20