5 Vent Information and Diagrams
A. Vent Guidelines |
| Rise to Run Ratio = 2:1 |
WARNING |
| Maximum Total Horizontal Run = 15 Feet |
| Minimum Total Vertical Rise = 9 Feet | |
Fire Risk. |
| Maximum Total Vertical Rise = 30 Feet |
| Maximum Number of Elbows: Two 900 or Four 450 | |
Asphyxiation Risk. |
| |
|
| |
This appliance requires the specified pipe for |
| |
operation. |
|
|
• Incorrect pipe may cause spillage, condensation | MINIMUM CLEARANCES | |
and overheating. |
| |
| ARE PER VENT | |
|
| MANUFACTURER’S |
These models require the following size | SPECIFICATIONS | |
| ||
wall, or single wall rigid or flex vent pipe. |
|
|
Models | Pipe Size | 9 FEET |
5 inches | MINIMUM | |
5 inches |
| |
6 inches |
| |
• | VENT SUPPORTS ARE PER | |
within combustible construction. |
| VENT MANUFACTURER’S |
|
| SPECIFICATIONS |
•Single wall rigid or flexible vent may be used ONLY if the vent system is installed within
•Follow pipe manufacturer’s installation guidelines when installing the appliance.
WARNING | Figure 5.1 |
|
| Fire Hazard. |
|
|
| Explosion Risk. |
|
|
| Asphyxiation Risk. |
|
|
| Do NOT connect this gas appliance to a |
|
|
| chimney flue serving a separate | VENT SUPPORTS |
|
| gas burning appliance. |
| |
| ARE PER VENT |
| |
| • Vent this appliance directly outside. | MANUFACTURER'S | METAL |
| • Use separate vent system for this appliance. | SPECIFICATIONS. | PLUMBERS' STRAP |
|
|
| |
| May impair safe operation of this appliance or |
|
|
| other appliances connected to the flue. |
|
|
B. Vent System Configuration | MAXIMUM HORIZONTAL RUN IS 50% | ||
|
| OF VERTICAL. HORIZONTAL RUN | |
| CAUTION | CANNOT BE MORE THAN 15 FT. | |
|
|
| |
ALL vent configuration specifications MUST be followed. |
|
| |
• | This product is tested and listed to appliance and vent |
|
|
| manufacturer’s specifications. |
|
|
• Appliance performance will suffer if specifications are not |
|
| |
| followed. | Figure 5.2 |
|
| Heat & Glo • | 13 |