Ensure that gas line does not come in contact with outer wrap of appliance. Follow local codes.

Incoming gas line should be piped into the valve com- partment and connected to the 1/2 inch connection on the manual shutoff valve.

WARNING

Fire or Explosion Hazard

• Gas build-up during line purge may ignite.

• Purge should be performed by qualified technician.

Ensure adequate ventilation.

Ensure there are no ignition sources such as sparks or open flames.

A small amount of air will be in the gas supply lines. When first lighting appliance it will take a short time for air to purge from lines. When purging is complete the appliance will light and operate normally.

WARNING

CHECK FOR GAS LEAKS

Explosion Risk

Fire Risk

Asphyxiation Risk

Check all fittings and connections.

Do not use open flame.

After the gas line installation is complete, all connections must be tightened and checked for leaks with a commercially-available, non- corrosive leak check solution. Be sure to rinse off all leak check solution following testing.

Fittings and connections may have loosened during shipping and handling.

WARNING

Fire hazard.

Explosion Risk.

Do NOT change the valve settings.

This valve has been preset at the factory.

Changing valve settings may result in fire hazard or bodily injury.

HIGH ALTITUDE INSTALLATIONS

U.L. Listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2000 feet in the U.S.A. and Canada.

When installing this appliance at an elevation above 2000 feet, it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size. Input rate should be reduced by 4% for each 1000 feet above a 2000 foot elevation in the U.S.A., or 10% for elevations between 2000 and 4500 feet in Canada. If the heating value of the gas has been reduced, these rules do not apply. To identify the proper orifice size, check with the local gas utility.

If installing this appliance at an elevation above 4500 feet (in Canada), check with local authorities.

20

Heat & Glo • SL-550 / 750 / 950TV-D2053-985 Rev. J • 4/07

Image 20
Contents What to do if you smell gas Congratulations Homeowner Reference InformationTable of Contents 1Listing and Code Approvals Glass SpecificationsBTU Specifications ModelsCombustible Materials Specification High Altitude InstallationsNon-Combustible Materials Specification Design and Installation Considerations Getting StartedNegative Pressure Tools and Supplies Needed Inspect Appliance and ComponentsFraming and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesMantel Projections Clearances to Mantels or other Combustibles above ApplianceTermination Locations Vent Termination Minimum ClearancesVent System Configuration Vent Information and DiagramsVent Guidelines Minimum Vertical Feet Vertical Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Gas and Electrical Connections Installing Outside Air Kit Damper AssemblyAppliance Preparation Securing and Leveling Appliance Proper Positioning, Leveling and Securing of aInstalling Vent Pipe Assembly of Vent SectionsSecuring Vent Sections Attaching Vent to FireboxGas Information Fuel Conversions Gas ConnectionGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Recommendation for Wire Connecting to the ApplianceIntellifire Ignition System Wiring Optional Accessories RequirementsStanding Pilot Ignition System Wiring Ground toJunction Box Installation Wall Switch Installation for Fan OptionalFinishing Facing MaterialAppliance Setup Clean the ApplianceAccessories Remove Shipping MaterialsLog Set Assembly LOGS-SL550-D Models SL-550TV-D Positioning the LogsTAB Locator Log Set Assembly LOGS-SL750-D Models SL-750TV-D, SL-950TV-D Notches Raised Flat Spots Glass Assembly Shutter SettingsScreen Mesh Grilles and TrimOperating Instructions Before Lighting ApplianceCheck Appliance Draft Before operating this appliance have a qualified technicianLighting Appliance Intellifire IgnitionFor Your Safety Read Before Lighting Instructions Standing Pilot IgnitionAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Standing Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Actions Troubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System Symptom Possible Causes Corrective Actions Maintaining and Servicing Appliance Before servicingInspect Maintenance Tasks Reference Materials Appliance Dimension DiagramAppliance Dimensions Table Service Parts Log Set AssemblyService Parts List SL-550TV-DSL-550TV-D, SL-550TV-IPI-D SL-750TV-D SL-750TV-D SL-750TV-D, SL-750TV-IPI-D SL-950TV-D SL-950TV-D SL-950TV-D, SL-950TV-IPI-D SL-550 / 750 / 950TV-D SL-550 / 750 / 950TV-D-IPI Limited Lifetime Warranty Limited Lifetime Warranty Heat & GLO GAS Appliance ProductsContact Information Do not Discard this Manual