11 Finishing
A. Mantel Projections
Figure 11.1 shows the minimum vertical and corresponding maximum horizontal dimensions of appliance mantels or other combustible projections above the top front edge of the appliance.
| 12 INCHES | |
| (305mm) | |
12 INCHES | ||
MATERIAL ONLY | ||
(305mm) | ||
| ||
| 1/2 INCH | |
| (13mm) | |
| TOP FRONT EDGE | |
| OF FIREPLACE |
Figure 11.1 Clearances to Mantels or other
Combustibles above Appliance
B. Facing Material
WARNING
Fire Risk.
Do NOT obstruct air inlet or outlet grilles.
Do NOT modify grilles.
•Modifying or covering grilles could cause
temperature rise and fire hazard.
Finishing materials must not interfere with:
•Air flow through grilles or louvers.
•Operation of louvers or doors.
•Access for service.
FINISH WALL MATERIAL |
MAY BE COMBUSTIBLE |
- TOP AND SIDES |
TOP SEAL |
JOINT |
SIDE SEAL |
JOINT |
1/2 INCH |
(13mm) |
1/2 INCH |
(13mm) |
Figure 11.3 Noncombustible Facing Diagram |
WARNING
Fire Risk.
Finish all edges and fronts to clearances and specifications listed in manual.
•Black metal appliance front may be covered with non- combustible material only.
•Do NOT overlap combustible materials onto appliance front.
•Install combustible materials up to specified clearances on top front and side edges.
•Seal joints between the finished wall and appliance top and sides using only a 300º F minimum sealant.