13 Operating Instructions

A. Before Lighting Appliance

Before lighting this appliance determine if it has a Standing Pilot or Intellifire ignition system by opening the control access panel to view wiring system and gas valve. If this appliance has a red or black ignitor button (see Figure 10.1) this appliance has a Standing Pilot ignition system. If there is no red or black ignitor button, this appliance has an Intellifire ignition system.

CAUTION

If installing Intellifire ignition battery backup:

Do not install batteries if the backup mode may not be used for extended time.

Batteries may leak.

Install batteries only when needed for power outage.

Before operating this appliance have a qualified technician:

Remove all shipping materials from inside and/or underneath the firebox.

WARNING

HOT! DO NOT TOUCH.

SEVERE BURNS MAY RESULT.

CLOTHING IGNITION MAY RESULT.

Glass and other surfaces are hot during operation and cool down.

• Keep children away.

• CAREFULLY SUPERVISE children in same room as appliance.

Alert children and adults to hazards of high temperatures.

Do NOT operate with protective barriers open or re- moved.

Keep clothing, furniture, draperies and other combustibles away.

This appliance has been supplied with an integral barrier to prevent direct contact with the fixed glass panel. Do NOT operate the appliance with the protective barrier removed. Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one.

Review proper placement of logs, rockwool, lava rock, and vermiculite.

Check the wiring.

Check the air shutter adjustment.

Ensure that there are no gas leaks.

Ensure that the glass is sealed and in the proper position.

WARNING

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier.

Ensure that the flow of combustion and ventilation air is

B. Check Appliance Draft

 

 

not obstructed (front grilles and vent caps).

Check draft of appliance to

 

 

 

 

DRAFT HOOD

 

 

 

verify proper venting condi-

 

 

WARNING

 

 

 

tions.

 

 

Glass door must be in place when

• Close all windows and

 

 

doors, turn on all exhaust

 

 

appliance is operating. Risk of:

 

 

fans in home.

FLAME UP

 

Combustion Fumes

 

• Appliance is to be com-

- ACCEPTABLE -

 

Fire

 

 

Do NOT operate appliance with glass door removed.

pletely assembled to nor-

 

 

• Open viewing glass for servicing only.

mal operating condition.

 

 

• Turn on appliance and al-

 

 

• Glass door MUST be in place and sealed before operating

 

 

appliance.

 

low to operate for at least

 

 

• Only use glass door certified for use with appliance.

10 minutes.

 

 

• Glass replacement should be done by qualified

• Check draft as shown in

FLAME IN

 

- GOOD -

 

technician.

 

Figure 13.1. This can be

 

 

 

 

 

 

done using a smoke or

 

 

 

WARNING

flame producing match.

 

 

 

• Hold lit match at bottom

 

 

Do NOT use this appliance if any part has been under water.

edge of draft hood opening

 

 

and observe flame/smoke

 

 

Immediately call a qualified service technician to inspect the

 

 

per the figure.

FLAME OUT

 

appliance and to replace any part of the control system and

 

 

- BAD -

 

any gas control which has been under water.

Figure

13.1

 

 

Heat & Glo • SL-550 / 750 / 950TV-D2053-985 Rev. J • 4/07

31

Image 31
Contents What to do if you smell gas Homeowner Reference Information CongratulationsTable of Contents Models 1Listing and Code ApprovalsGlass Specifications BTU SpecificationsNon-Combustible Materials Specification High Altitude InstallationsCombustible Materials Specification Getting Started Design and Installation ConsiderationsNegative Pressure Inspect Appliance and Components Tools and Supplies NeededSelecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseClearances to Mantels or other Combustibles above Appliance Mantel ProjectionsVent Termination Minimum Clearances Termination LocationsVent Guidelines Vent Information and DiagramsVent System Configuration Minimum Vertical Feet Pipe Clearances to Combustibles Vent Clearances and FramingVertical Penetration Framing Appliance Preparation Installing Outside Air Kit Damper AssemblyGas and Electrical Connections Proper Positioning, Leveling and Securing of a Securing and Leveling ApplianceAttaching Vent to Firebox Installing Vent PipeAssembly of Vent Sections Securing Vent SectionsPressure Natural Gas Propane Gas InformationFuel Conversions Gas Connection Gas PressuresHigh Altitude Installations Optional Accessories Requirements Recommendation for WireConnecting to the Appliance Intellifire Ignition System WiringGround to Standing Pilot Ignition System WiringWall Switch Installation for Fan Optional Junction Box InstallationFacing Material FinishingRemove Shipping Materials Appliance SetupClean the Appliance AccessoriesPositioning the Logs Log Set Assembly LOGS-SL550-D Models SL-550TV-DTAB Locator Log Set Assembly LOGS-SL750-D Models SL-750TV-D, SL-950TV-D Notches Raised Flat Spots Grilles and Trim Glass AssemblyShutter Settings Screen MeshBefore operating this appliance have a qualified technician Operating InstructionsBefore Lighting Appliance Check Appliance DraftIntellifire Ignition Lighting ApplianceStanding Pilot Ignition For Your Safety Read Before Lighting InstructionsInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Symptom Possible Causes Corrective Actions TroubleshootingStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingIntellifire Ignition System Symptom Possible Causes Corrective Actions Before servicing Maintaining and Servicing ApplianceInspect Maintenance Tasks Appliance Dimensions Table Appliance Dimension DiagramReference Materials Log Set Assembly Service PartsSL-550TV-D Service Parts ListSL-550TV-D, SL-550TV-IPI-D SL-750TV-D SL-750TV-D SL-750TV-D, SL-750TV-IPI-D SL-950TV-D SL-950TV-D SL-950TV-D, SL-950TV-IPI-D SL-550 / 750 / 950TV-D SL-550 / 750 / 950TV-D-IPI Limited Lifetime Warranty Heat & GLO GAS Appliance Products Limited Lifetime WarrantyDo not Discard this Manual Contact Information