Heat & Glo LifeStyle SL-950TV-IPI-D Troubleshooting, Symptom Possible Cause Corrective Action

Page 36

Troubleshooting (continued)

Symptom

Possible Cause

Corrective Action

 

 

 

3. ...Continued

c. Defective valve.

Turn the valve knob to the ON position. Place the ON/OFF

 

 

switch in the ON position. Check the millivolt meter a the ther-

 

 

mopile terminals. The millivolt meter should read greater than

 

 

125mV. If the reading is acceptable, and if the burner does not

 

 

come on, replace the gas valve.

 

 

 

 

d. Plugged burner orifice.

Check the burner orifice for stoppage. Remove stoppage.

 

 

 

 

e. Wall switch or wires are

Follow the corrective action in Symptom and Possible Cause 1.a

 

defective.

above. Check the switch and wiring. Replace where defective.

 

 

 

4. Frequent pilot

a. Pilot flame may be too

Clean thermocouple and adjust the pilot flame for maximum

outage problem.

high or too low, or blowing

flame impingement. Follow lighting instructions carefully.

 

out (high pressure), causing

 

 

pilot safety to drop out.

 

 

 

 

5. The pilot and

a. No LP in tank.

Check the LP (propane) tank. Refill the fuel tank.

main burner ex-

 

 

tinguish while in

b. Inner vent pipe leaking

Check venting system for damage. Replace/repair improperly

operation.

exhaust gases back into the

assembled pipe sections.

 

 

system.

 

 

 

 

 

c. Glass too loose and air

Replace glass panel assembly.

 

tight packet leaks in corners

 

 

after usage.

 

 

 

 

 

d. Bad thermopile or thermo-

Replace if necessary.

 

couple.

 

 

 

 

 

e. Improper vent cap instal-

Check for proper installation and freedom from debris or block-

 

lation.

age.

 

 

 

6. Glass soots.

a. Flame impingement.

Adjust the log set so that the flame does not excessively impinge

 

 

on it.

 

 

 

 

b. Improper air shutter set-

Adjust the air shutter located on the control panel.

 

ting.

 

 

 

 

 

c. Debris around air shutter.

Inspect the opening at the base of the burner. NO MATERIAL

 

 

SHOULD BE PLACED IN THIS OPENING.

 

 

 

7. Flame burns

a. Insufficient oxygen being

Ensure that the vent cap is installed properly and free of debris.

blue and lifts off

supplied.

Ensure that the vent system joints are tight and have no leaks.

burner.

 

Ensure that no debris has been placed at the base of, or in the

 

 

 

 

area of the air holes in the center of the base pan beneath the

 

 

burner.

 

 

Ensure that the glass is tightened properly on the unit, particu-

 

 

larly on top corners.

 

 

 

36

Heat & Glo • SL-550 / 750 / 950TV-D2053-985 Rev. J • 4/07

Image 36
Contents What to do if you smell gas Congratulations Homeowner Reference InformationTable of Contents 1Listing and Code Approvals Glass SpecificationsBTU Specifications ModelsHigh Altitude Installations Non-Combustible Materials SpecificationCombustible Materials Specification Design and Installation Considerations Getting StartedNegative Pressure Tools and Supplies Needed Inspect Appliance and ComponentsFraming and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesMantel Projections Clearances to Mantels or other Combustibles above ApplianceTermination Locations Vent Termination Minimum ClearancesVent Information and Diagrams Vent GuidelinesVent System Configuration Minimum Vertical Feet Vent Clearances and Framing Pipe Clearances to CombustiblesVertical Penetration Framing Installing Outside Air Kit Damper Assembly Appliance PreparationGas and Electrical Connections Securing and Leveling Appliance Proper Positioning, Leveling and Securing of aInstalling Vent Pipe Assembly of Vent SectionsSecuring Vent Sections Attaching Vent to FireboxGas Information Fuel Conversions Gas ConnectionGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Recommendation for Wire Connecting to the ApplianceIntellifire Ignition System Wiring Optional Accessories RequirementsStanding Pilot Ignition System Wiring Ground toJunction Box Installation Wall Switch Installation for Fan OptionalFinishing Facing MaterialAppliance Setup Clean the ApplianceAccessories Remove Shipping MaterialsLog Set Assembly LOGS-SL550-D Models SL-550TV-D Positioning the LogsTAB Locator Log Set Assembly LOGS-SL750-D Models SL-750TV-D, SL-950TV-D Notches Raised Flat Spots Glass Assembly Shutter SettingsScreen Mesh Grilles and TrimOperating Instructions Before Lighting ApplianceCheck Appliance Draft Before operating this appliance have a qualified technicianLighting Appliance Intellifire IgnitionFor Your Safety Read Before Lighting Instructions Standing Pilot IgnitionFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Symptom Possible Causes Corrective ActionsStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System Symptom Possible Causes Corrective Actions Maintaining and Servicing Appliance Before servicingInspect Maintenance Tasks Appliance Dimension Diagram Appliance Dimensions TableReference Materials Service Parts Log Set AssemblyService Parts List SL-550TV-DSL-550TV-D, SL-550TV-IPI-D SL-750TV-D SL-750TV-D SL-750TV-D, SL-750TV-IPI-D SL-950TV-D SL-950TV-D SL-950TV-D, SL-950TV-IPI-D SL-550 / 750 / 950TV-D SL-550 / 750 / 950TV-D-IPI Limited Lifetime Warranty Limited Lifetime Warranty Heat & GLO GAS Appliance ProductsContact Information Do not Discard this Manual