A. Recommendation for Wire

This appliance requires 110-120 VAC be wired to the junction box either for use of optional accessories (stand- ing pilot ignition) or for proper operation of the appliance (Intellifire ignition). Refer to Figure 10.1 to determine if the appliance uses an Intellifire ignition system or Standing Pilot ignition system.

Open the control access panel to view wiring system and gas valve. If this appliance has a red or black ignitor button (as noted in Figure 10.1) this appliance has a Standing Pilot ignition system. If there is no red or black ignitor button, this appliance has an Intellifire ignition system.

Figure 10.1

Standing Pilot Ignition

NOTE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code, CSA C221.1.

B. Connecting to the Appliance

WARNING

Wire 110V to electrical junction box.

Do NOT wire 110V to valve.

Do NOT wire 110V to wall switch.

Incorrect wiring will damage millivolt valves.

Incorrect wiring will override IPI safety lockout and may cause explosion.

This appliance MUST be used with a wall switch or a remote control.

If using thermostat use one compatible with a millivolt gas valve system.

Follow parameters for locating thermostat (see individual thermostat instructions) to ensure proper operation of appliance.

Use low resistance thermostat wire for wiring from igni- tion system to the wall switch and thermostat.

Keep wire lengths short as possible by removing any excess wire length.

Low voltage and 110 VAC voltage cannot be shared within the same wall box.

C.Intellifire Ignition System Wiring

This appliance requires a 110 VAC supply to the appliance junction box for operation. A wiring diagram is shown in Figure 10.2.

This appliance is equipped with an Intellifire control valve which operates on a 3 volt system.

This appliance is supplied with a battery pack and a 3 volt AC transformer, which requires the installation of the sup- plied junction box. It is highly recommended that the junc- tion box be installed at this time to avoid reconstruction.

The battery pack requires two D cell batteries (not included).

NOTE: Batteries cannot be placed in the battery pack while using the 3 volt AC transformer. The transformer must be unplugged if the battery pack is used or battery life will be reduced.

CAUTION

Battery polarity must be correct or module damage will occur.

Optional Accessories Requirements

Wiring for optional accessories should be done now to avoid reconstruction.

CAUTION

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

WARNING

Shock hazard.

Replace damaged wire with type 105º C rated wire.

Wire must have high temperature insulation.

Heat & Glo • SL-550 / 750 / 950TV-D2053-985 Rev. J • 4/07

21

Image 21
Contents What to do if you smell gas Homeowner Reference Information CongratulationsTable of Contents Glass Specifications 1Listing and Code ApprovalsBTU Specifications ModelsHigh Altitude Installations Non-Combustible Materials SpecificationCombustible Materials Specification Getting Started Design and Installation ConsiderationsNegative Pressure Inspect Appliance and Components Tools and Supplies NeededSelecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseClearances to Mantels or other Combustibles above Appliance Mantel ProjectionsVent Termination Minimum Clearances Termination LocationsVent Information and Diagrams Vent GuidelinesVent System Configuration Minimum Vertical Feet Vent Clearances and Framing Pipe Clearances to CombustiblesVertical Penetration Framing Installing Outside Air Kit Damper Assembly Appliance PreparationGas and Electrical Connections Proper Positioning, Leveling and Securing of a Securing and Leveling ApplianceAssembly of Vent Sections Installing Vent PipeSecuring Vent Sections Attaching Vent to FireboxFuel Conversions Gas Connection Gas InformationGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Connecting to the Appliance Recommendation for WireIntellifire Ignition System Wiring Optional Accessories RequirementsGround to Standing Pilot Ignition System WiringWall Switch Installation for Fan Optional Junction Box InstallationFacing Material FinishingClean the Appliance Appliance SetupAccessories Remove Shipping MaterialsPositioning the Logs Log Set Assembly LOGS-SL550-D Models SL-550TV-DTAB Locator Log Set Assembly LOGS-SL750-D Models SL-750TV-D, SL-950TV-D Notches Raised Flat Spots Shutter Settings Glass AssemblyScreen Mesh Grilles and TrimBefore Lighting Appliance Operating InstructionsCheck Appliance Draft Before operating this appliance have a qualified technicianIntellifire Ignition Lighting ApplianceStanding Pilot Ignition For Your Safety Read Before Lighting InstructionsFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Symptom Possible Causes Corrective ActionsStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingIntellifire Ignition System Symptom Possible Causes Corrective Actions Before servicing Maintaining and Servicing ApplianceInspect Maintenance Tasks Appliance Dimension Diagram Appliance Dimensions TableReference Materials Log Set Assembly Service PartsSL-550TV-D Service Parts ListSL-550TV-D, SL-550TV-IPI-D SL-750TV-D SL-750TV-D SL-750TV-D, SL-750TV-IPI-D SL-950TV-D SL-950TV-D SL-950TV-D, SL-950TV-IPI-D SL-550 / 750 / 950TV-D SL-550 / 750 / 950TV-D-IPI Limited Lifetime Warranty Heat & GLO GAS Appliance Products Limited Lifetime WarrantyDo not Discard this Manual Contact Information