FLUE TERMINATION APPROVALS
Flue System Approvals And Installations
These models have flue starting collars on both the top and the back of the unit. Depending upon the installation, decide which ONE set of starting collars will be used to at- tach the flue system. The starting collar sealing cap must remain on the starting collar NOT used.
These models use DVP and SLP series direct flue com- ponents when using the TOP flue collars and
Approved flue system components are labeled for identi- fication. NO OTHER FLUEING SYSTEMS OR COMPO- NENTS MAY BE USED. Detailed installation instructions are included with each flue termination kit and should be used in conjunction with this manual. Figure 7.9 shows flue system components and terminations.
Identifying Flue Components
The flue systems installed on this gas heater may include one, two, or three 90° elbow assemblies. The relationships of vertical rise to horizontal run in flue configurations using 90° elbows MUST BE strictly adhered to. The rise to run relationships are shown in the flueing drawings and tables on the next few pages.
WARNING! Risk of Fire! This gas appliance and flue as- sembly must flue directly to the outside and must never be attached to a chimney serving a separate solid fuel burning appliance. Each gas appliance must use a sepa- rate flue
WARNING! Risk of Fire! DO NOT apply combustible materials beyond the minimum clearances. Comply with all minimum clearances to combustibles as specified in this manual. Overlapping material could ignite and will in- terfere with proper operation of doors and louvers.
•Horizontal sections 3 in. (76 mm) from the top of the pipe.
•Horizontal sections
•Horizontal sections 1 in. (25 mm) from sides and bottom of the pipe.
•Vertical sections 1 in. (25 mm) on all sides of pipe.
Failure to keep insulation or other material away from vent pipe may cause over heating and fire.
For alternative installations, other than depicted, contact your dealer for further information.
|
| VERTICAL | STORM COLLAR |
|
|
| TERMINATION |
|
|
|
| HORIZONTAL | ROOF FLASHING |
|
|
| TERMINATION |
|
|
|
|
| HORIZONTAL PIPE | |
|
|
| SUPPORT | |
|
|
|
| PIPE LENGTH |
| WALL FIRESTOP |
|
| |
|
| 90 DEGREE |
|
|
|
| ELBOW | CEILING | WALL BRACKET |
|
|
| ||
| Flue system termination kits | FIRESTOP |
| |
|
|
| ||
SLP SERIES |
|
|
| |
| ||||
Figure 7.9 Flue Components and Terminations |
|
| ||
| Heat & Glo • | 31 |