Heat & Glo LifeStyle 550TRSI-AUF owner manual Table of Contents, User Guide

Page 5

Safety Alert Key:

DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.

WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.

CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

NOTICE: Used to address practices not related to personal injury.

Table of Contents

A. Congratulations

.

3

D. Mantel and Wall Projections

23

B. SANS Compliance

.

4

6 Termination Locations

 

C. Limited Lifetime Warranty

 

. 7

 

1 Listing and Code Approvals

 

 

A. Vent Termination Minimum Clearances

. 24

 

 

7 Vent Information and Diagrams

 

A. Appliance Certification

 

10

 

B. Gas Pressure Requirements

. 10

A. Approved Pipe

26

C. High Altitude Installations

 

10

B. Vent Table Key

26

D. Non-Combustible Materials Specification

. 10

C. Use of Elbows

26

E. Combustible Materials Specification

. 10

D. Measuring Standards

. 26

F. Electrical Codes

. 10

E. Vent Diagrams

26

User Guide

2 Operating Instructions

A.

Gas Fireplace Safety

. 11

B.

Your Fireplace

11

C.

Fan Kit

12

D.

Clear Space

12

E.

Decorative Doors and Fronts

. 12

F.

Fixed Glass Assembly

12

G. Remote Controls, Wall Controls and Wall Switches. . . 12

H. Before Lighting Fireplace

12

I.

Lighting Instructions (IPI)

13

J.

Control Module Operation

. 14

K.

After Fireplace is Lit

15

L.

Frequently Asked Questions

. 15

3 Maintenance and Service

A. Maintenance Tasks-Homeowner . . . . . . . . . . 16

B. Maintenance Tasks-Qualified Service Technician . . . . 17

Installer Guide

4 Getting Started

A.Typical Appliance System. . . . . . . . . . . . . . . . . . . . . . . . . 18

B.Design and Installation Considerations . . . . . . . . 19

C.Tools and Supplies Needed. . . . . . . . . . . . 19

D.Inspect Appliance and Components. . . . . . . . . 19

5 Framing and Clearances

A. Selecting Appliance Location. . . . . . . . . . . . 20 B. Constructing the Appliance Chase. . . . . . . . . . 21 C. Clearances. . . . . . . . . . . . . . . . . . . 21

8 Vent Clearances and Framing

A. Pipe Clearances to Combustibles . . . . . . . . . . 38 B. Wall Penetration Framing. . . . . . . . . . . . . 38 C. Install the Ceiling Firestop . . . . . . . . . . . . . 39 D. Install Attic Insulation Shield. . . . . . . . . . . . 40 E. Installing the Optional Heat-Zone®-240V Kit . . . . . . 40

9 Appliance Preparation

A.

Top Vent

. 41

B.

Rear Vent

42

C.Installing the Non-combustible Board. . . . . . . . . . . . . . . . 43

D.Securing and Leveling the Appliance. . . . . . . . . 43

E.Covers Removal For Servicing. . . . . . . . . . . . . . . . . . . . . 44

F.Components Removal For Service . . . . . . . . . 44

G.Parts Replacement . . . . . . . . . . . . . . . 44

H.Adjustments And Replacement Parts. . . . . . . . . 44

I.Install Trim and/or Surround. . . . . . . . . . . . 44

J.Air Shutter Setting . . . . . . . . . . . . . . . . 44

10 Installing Vent Pipe (DVP and SLP Pipe)

A. Assemble Vent Sections (DVP Pipe Only). . . . . . . 45 B. Assemble Vent Sections (SLP Pipe Only). . . . . . . 46 C. Assemble Slip Sections. . . . . . . . . . . . . . 46 D. Secure the Vent Sections. . . . . . . . . . . . . 47 E. Disassemble Vent Sections. . . . . . . . . . . . 47 F. Install Support Brackets. . . . . . . . . . . . . . 48 G. Install Firestops . . . . . . . . . . . . . . . . . 48 H. Flue Termination. . . . . . . . . . . . . . . . . 49

I.Heat Shield Requirements for Horizontal Termination. . 50

J.Install Metal Roof Flashing. . . . . . . . . . . . . 50

K.Assemble and Install Storm Collar. . . . . . . . . . 51

Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF2079-980 Rev. N • 5/12

5

Image 5
Contents Ref No GSCS20163 Sans 15392008 AS45532008 Models 550TRSI-AUF 550TRSILP-AUFWhat to do if you smell gas Hot glass will cause burnsModels 550TRSI-AUF, 550TRSILP-AUF Homeowner Reference Information CongratulationsSans Novida Testing ServiceSans Compliance User Guide Table of ContentsTroubleshooting Appliance SetupGas Information Electrical InformationLimited Lifetime Warranty Australian Warranty InformationOther Rights Perth This warranty is void ifListing and Code Approvals Your Fireplace Gas Fireplace SafetyOperating Instructions User Guide Remote Controls, Wall Controls and Wall Switches Fixed Glass AssemblyFan Kit Clear SpaceFinal inspection by Lighting Instructions IPIControl Module Operation Nine Hour Safety Shutdown FeatureAfter Fireplace is Lit Frequently Asked QuestionsMaintenance and Service Gasket Seal and Glass Assembly Inspection Maintenance Tasks-Qualified Service TechnicianLogs FireboxTypical Appliance System Getting StartedTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Any such action may cause a fire hazardSelecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseMinimum Framing Dimensions Combustible Mantel Legs or Wall Projections Mantel and Wall ProjectionsCombustible Mantels Vent Termination Minimum Clearances Termination LocationsClearance MIN. Clearance in. mmVent Information and Diagrams V1 Minimum H1 Maximum Top Vent Horizontal TerminationMinimum + H 2 Maximum Top Vent Horizontal Termination Two ElbowsMin Max Three ElbowsStraight Up Vertical Flue System Top Vent Vertical TerminationFlue Termination Approvals Flue System Approvals And InstallationsH1 Maximum V1 + V2 Min Top Vent Vertical Termination Two ElbowsH1 + H2 V1 + V2 Minimum H1 + H2 Maximum Top Vent Vertical Termination Three ElbowsH1 Minimum H1 Maximum Rear Vent Horizontal Termination No ElbowOne 45º Elbow H3H2 Rear Vent Horizontal Termination Two ElbowsV1 Minimum H1 + H2 Maximum Rear Vent Vertical Termination One Elbow Two ElbowsMinimum Maximum Minimum + H 2 + H Maximum Rear Vent Vertical Termination Three ElbowsMaximum Minimum + H 2 Maximum Pipe Clearances to Combustibles Wall Penetration Framing Vent Clearances and FramingCombustible Wall Penetration Non-Combustible Wall PenetrationPipe DVP SLP Install the Ceiling FirestopInstalling the Optional Heat-Zone-240V Kit Install Attic Insulation ShieldFlat Ceiling Installation Vaulted Ceiling InstallationTop Vent Appliance PreparationCut the metal retaining band and fold the sides out Rear VentSecuring and Leveling the Appliance Installing the Non-combustible BoardParts Replacement Components Removal For ServiceAdjustments And Replacement Parts Install Trim and/or SurroundAttach Vent to the Firebox Assembly Installing Vent Pipe DVP and SLP PipeAssemble Vent Sections DVP Pipe Only Assemble Pipe SectionsAssemble Slip Sections Assemble Vent Sections SLP Pipe OnlyDisassemble Vent Sections Secure the Vent SectionsInstall Firestops Install Support BracketsFlue Termination For Horizontal Terminations using the SLP-TRAP2 or DVP-TRAP2Heat Shield Requirements for Horizontal Termination Install Metal Roof FlashingInstall Vertical Termination Cap Assemble and Install Storm CollarGas Connection Gas InformationGAS Access IntelliFire Plus Ignition System Wiring Wiring RequirementsOptional Accessories Requirements Optional Remote Control Receiver LocationBlower Installation Precautions Kit ContentsFireplace Specific Information IntroductionInstallation of Remote Control Housing Changing Temperature ScaleProgramming the RC300AU to the Control Module AUX300CE Module InstallationFan Installation Standby mode Idle When Remote is in on ModeDisplay Screen Function ButtonsAbout OFF Mode About on ModeAdjusting Flame Height Adjusting Fan SpeedAdjusting Timer Adjusting ThermostatSetting the Child Lock Power OutageSymptom Possible Cause Corrective Action Frequently Asked Questions/Troubleshooting816 940 FinishingFacing Material Remove Fixed Glass Assembly Appliance SetupClean the Appliance Accessories3 4 5 6 7 Log Placement InstructionsHeat & Glo 550TRSI-AUF, 550TRSILP-AUF 2079-980 Rev. N 5/12 Heat & Glo 550TRSI-AUF, 550TRSILP-AUF 2079-980 Rev. N 5/12 IntelliFire Plus Ignition System TroubleshootingSymptom Possible Cause Corrective Action Troubleshooting Location Inches Millimeters Appliance Dimension DiagramReference Materials Inspect Maintenance Tasks Maintenance TasksDVP-AS2 Vent Components DiagramsHorizontal Termination Cap Mm Heat Shield 15-1/8 384 mmEffective Length DVP-HRC-SS DVP-HRC-ZC-SS 165 mm 222 mm 235 mm 152 mm 168 mm 165 mmElbow 251 mmEffective Heat Shield 15-1/8 384 mmCathedral Ceiling HorizontalLog Set Assembly Service PartsBeginning Manufacturing Date July Ending Manufacturing Date #19 Valve AssemblyConversion Kits Service Parts ListContact Information