Vermont Casting DTV38s2 installation instructions General Venting Information Termination Location

Page 16

Chateau™ Direct Vent Gas Fireplace

General Venting Information - Termination Location

INSIDE

CORNER DETAIL

D

E V L

C

G

V

A

B

H N N

B

CFM145a

V�����

������

F

V

Operable

 

B

V

 

B

V

 

Operable

Fixed

 

 

 

Closed

 

 

 

 

 

 

 

V J

B

M

B

X

V K X

 

A

 

I

 

 

 

 

CFM145 V VENT TERMINATION X AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED

 

 

Canadian Installations1

US Installations2

A =

Clearance above grade, veranda, porch,

12” (30 cm)

12” (30 cm)

 

deck, or balcony

 

 

B = Clearance to window or door that may be

6” (15 cm) for appliances

6” (15 cm) for appliances

 

opened

< 10,000Btuh (3kW), 12” (30 cm)

< 10,000 Btuh (3kW), 9”

 

 

for appliances > 10,000 Btuh (3kW) and

(23 cm) for appliances > 10,000

 

 

< 100,000 Btuh (30kW), 36” (91 cm)

Btuh (3kW) and < 50,000 Btuh

 

 

for appliances > 100,000 Btuh (30kW)

(15kW), 12” (30 cm) for

 

 

 

appliances > 50,000 Btuh (15kW)

C* =Clearance to permanently closed window

12” (305 mm) recommended to

12” (305 mm) recommended to

 

 

prevent window condensation

prevent window condensation

D* =Vertical clearance to ventilated soffit located

 

 

 

above the terminal within a horizontal

18” (458 mm)

18” (458 mm)

 

distance of 2’ (610mm) from the center

*CAUTION: Clearances to soffit do not apply to “vinyl soffits”.

 

line of the terminal

 

 

 

E = Clearance to unventilated soffit

24” (610 mm)

24” (610 mm)

F =

Clearance to outside corner

see next page

see next page

G = Clearance to inside corner (see next page)

see next page

see next page

H = Clearance to each inside of center line

3’ (91 cm) within a height of 15’ (5m)

3’ (91 cm) within a height of 15’

 

extended above meter/regulator assembly

above the meter/regulator assembly

(5 m) above the meter/regulator

 

 

 

assy

I =

Clearance to service regulator vent outlet

3’ (91 cm)

3’ (91 cm)

J =

Clearance to nonmechanical air supply inlet

6” (15 cm) for appliances < 10,000

6” (15 cm) for appliances

 

to building or the combustion air inlet to any

Btuh (3kW), 12” (30 cm) for

< 10,000 Btuh (3kW), 9”

 

other appliances

appliances > 10,000 Btuh (3kW) and <

(23 cm) for appliances > 10,000

 

 

100,000 Btuh (30kW), 36” (91 cm)

Btuh (3kW) and < 50,000 Btuh

 

 

for appliances > 100,000 Btuh (30kW)

(15kW), 12” (30cm) for

 

 

 

appliances > 50,000 Btuh (15kW)

K =

Clearance to a mechanical air supply inlet

6’ (1.83 m)

3’ (91 cm) above if within 10’

 

 

 

(3 m) horizontally

L =

Clearance above paved sidewalk or paved

7’ (2.13 m)†

7’ (2.13 m)†

 

driveway located on public property

 

 

M = Clearance under veranda, porch, deck or

12” (30 cm)‡

12” (30 cm)‡

 

balcony

 

 

N = Clearance above a roof shall extend a minimum of 24” (610 mm) above the highest point when it passes through the roof surface, and any other obstruction within a horizontal distance of 18” (450 mm).

1 In accordance with the current CSA-B149 Installation Codes

2 In accordance with the current ANSI Z223.1/NFPA 54 National Fuel Gas Codes

A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings

‡ only permitted if veranda, porch, deck or balcony is fully open on a minimum 2 sides beneath the floor: NOTE: 1. Local codes or regulations may require different clearances.

2.The special venting system used on Direct Vent Fireplaces are certified as part of the appliance, with clearances tested and approved by the listing agency.

3.CFM Corporation assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements.

Fig. 11 Vent termination clearances.

16

20011957

Image 16
Contents INSTALLER/CONSUMER Safety Information What to do if YOU Smell GASTable of Contents Installation & Operating Instructions Certified ToAnsi Z21.50b-2005 / CSA 2.22b-2005 Vented Gas Fireplace Please Review the Following CarefullyClear of ALL Obstructions Requirements for the Commonwealth of MassachusettsGas Equipment Venting System not Provided Locating Your Fireplace Standard FramingClearance to Combustibles MantelsFraming and Finishing HearthFinal Finishing Gas Line Installation Gas SpecificationsGas Inlet and Manifold Pressures High ElevationsControl System Installation Control SystemSpecial Feature for Cold Climates Inside view of wireless wall switchHand-Held Remote Control Transmitter Operating Instructions Key SettingsIntroduction LCD Liquid Crystal DisplayManual Function Thermostat FunctionCP Childproof Feature Continuous Pilot FeatureSetting LOCK-OUT CP Thermostatic Updating Feature Operational NotesGeneral Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationUSA Installations Canadian InstallationsGeneral Information Assembling Vent Pipes SK8 Venting Pipes Vertical Termination Horizontal TerminationSidewall Applications Sidewall Installation StepAlways install horizontal venting on a level plane Zero clearance sleeve is only required for combustible wallsSidewall Installation with Stationary Glass Facing Outside Horizontal length requirementInstallation Procedure Installing the 38S2VDK DoorFlue Restrictor Plate Installation Restrictor Plate InstallationFlue Restrictor Plate Guide Typical ApplicationsFlue restrictor plate use in straight up installation Vertical Through-the-Roof Installation + 2 + 3 + 4 =Min Chimney Components Component Description Model NumberGlass Frame Assembly Removal Glass CleaningCeramic Refractory Installation Clean the glass after the first two weeks of operationLog, Lava Rock and Ember Placement DVT38Sw log identificationLog Pilot Plumbing F50 Overlay is very fragile Log Right Flame Characteristics Trim Installation Lighting Instructions Lighting & Operating InstructionsTurning Off the Gas to the Appliance American Flame Gas Control System TroubleshootingOperation Troubleshooting American Flame Gas Control System American Flame Gas Control System Error Codes What to CheckConversion Procedure Conversion PrecautionsFuel Conversion Instructions Remove pilot orifice Pilot Flame Adjustment DVT38S2 Injector Orifice Size MatrixValve Minimum Rate Screw Conversion to LPCleaning the Control System MaintenanceBurner and Burner Compartment DVT38S2 Units GFYW5Q0 DVT38S2 DVT38S2Fuel Conversion Kits Back-up Battery Kit AccessoriesWall Mountable Wireless Remote Transmitter Limited Lifetime Warranty Product Covered by this WarrantyEfficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %