Vermont Casting DTV38s2 Pilot Flame Adjustment, DVT38S2 Injector Orifice Size Matrix

Page 41

Chateau™ Direct Vent Gas Fireplace

22.Turn on gas supply and operate valve with remote control as needed to indicate gas pressure. The manifold pressure for LP should be approximately 10.0” wcp.

CAUTION: Turn off the valve and gas supply before removing test port adaptor and replac- ing plug.

23.After test, remove adaptor and replace plug.

24.Turn on gas supply and check that plugs are tight and leak free.

25.Follow instructions in Homeowner’s Manual to re-assemble brick panels, logs, lava rock, volcanic rock, embers and andirons.

26.Replace glass frame.

27.Conversion complete.

Pilot Flame Adjustment

Typically, the top 3/8” or 1/2” of the pilot flame sensor should be engulfed in the pilot flame. (Page 33, Fig. 52)

To adjust pilot burner:

1.Locate pilot adjustment screw on the valve next to the black plastic cap. Refer to Page 35.

2.Adjust pilot screw to provide proper sized flame. Only a small adjustment should be needed.

NOTE: Do not rotate screw excessively. Do not adjust any other screws on the valve.

Table 1 DVT38S2 Injector Orifice Size Matrix

Conversion to LP

KiT #

 

 

Burner

 

 

 

 

 

 

 

20012368

Burner

 

Housing/

 

Burner

 

Burner

 

Input (BTU/hr)

Model

Housing

Part #

Pilot*

Part #

Tube

Part #

Tube

Part #

Min.

Max.

DVT38S2IP

#55

30000333

#54

20000130

#57

20004587

#57

20004587

38,000

56,000

 

(.052”)

 

(.055”)

 

(.043”)

 

(.043”)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 2 Valve Minimum Rate Screw

Model

Drill Size

Part #

DVT38S2IP

No Shank

20012264

 

Screw

 

20011957

41

Image 41
Contents What to do if YOU Smell GAS INSTALLER/CONSUMER Safety InformationTable of Contents Certified To Installation & Operating InstructionsAnsi Z21.50b-2005 / CSA 2.22b-2005 Vented Gas Fireplace Please Review the Following CarefullyGas Equipment Venting System not Provided Requirements for the Commonwealth of MassachusettsClear of ALL Obstructions Standard Framing Locating Your FireplaceMantels Clearance to CombustiblesFinal Finishing HearthFraming and Finishing Gas Specifications Gas Line InstallationGas Inlet and Manifold Pressures High ElevationsControl System Control System InstallationInside view of wireless wall switch Special Feature for Cold ClimatesKey Settings Hand-Held Remote Control Transmitter Operating InstructionsIntroduction LCD Liquid Crystal DisplayThermostat Function Manual FunctionSetting LOCK-OUT CP Continuous Pilot FeatureCP Childproof Feature Operational Notes Thermostatic Updating FeatureLocation of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2General Information Assembling Vent Pipes SK8 Venting Pipes Canadian InstallationsUSA Installations Sidewall Applications Horizontal TerminationVertical Termination Step Sidewall InstallationZero clearance sleeve is only required for combustible walls Always install horizontal venting on a level planeHorizontal length requirement Sidewall Installation with Stationary Glass Facing OutsideInstalling the 38S2VDK Door Installation ProcedureRestrictor Plate Installation Flue Restrictor Plate InstallationFlue Restrictor Plate Guide Typical ApplicationsFlue restrictor plate use in straight up installation + 2 + 3 + 4 = Vertical Through-the-Roof InstallationMin Component Description Model Number Chimney ComponentsGlass Cleaning Glass Frame Assembly RemovalCeramic Refractory Installation Clean the glass after the first two weeks of operationDVT38Sw log identification Log, Lava Rock and Ember PlacementLog Pilot Plumbing F50 Overlay is very fragile Log Right Flame Characteristics Trim Installation Turning Off the Gas to the Appliance Lighting & Operating InstructionsLighting Instructions Operation TroubleshootingAmerican Flame Gas Control System Troubleshooting American Flame Gas Control System What to Check American Flame Gas Control System Error CodesFuel Conversion Instructions Conversion PrecautionsConversion Procedure Remove pilot orifice DVT38S2 Injector Orifice Size Matrix Pilot Flame AdjustmentValve Minimum Rate Screw Conversion to LPBurner and Burner Compartment MaintenanceCleaning the Control System DVT38S2 Units GFYW5Q0 DVT38S2 DVT38S2Fuel Conversion Kits Wall Mountable Wireless Remote Transmitter AccessoriesBack-up Battery Kit Product Covered by this Warranty Limited Lifetime WarrantyModel EnerGuide Ratings Fireplace Efficiency % Efficiency Ratings