Vermont Casting DTV38s2 Troubleshooting American Flame Gas Control System

Page 37

 

 

 

Chateau™ Direct Vent Gas Fireplace

Troubleshooting American Flame Gas Control System (continued)

Pilot is burning, but ignitor

Check that flame sensor is fully inpinged by pilot flame. If not, adjust pilot.

continues to spark

Check end-to-end continuity of sensor. If sensor has continuity, repalce module.

 

 

 

Main flame will not light

Verify the gas supply is turned on.

 

 

Ensure the pilot flame will ignite. If not, see pilot flame troubleshooting above.

 

 

Make sure the green and white leads from the module are securely connected to

 

 

the terminals labeled “MAIN: on the valve body.

 

 

Make certain the pilot flame is in contact with the flame rectification sensor on the

 

 

pilot assembly. This valve is equipped with a pilot flame adjustment screw. If the

 

 

pilot flame is too small it will not contact the flame rectification sensor and will not

 

 

complete the safety circuit.

 

 

Ensure the pilot flame is properly located to ignite the main flame.

 

 

Does the remote show CP in the display? If yes, childproof is on. Refer to transmit-

 

 

ter operating instructions in this manual.

 

 

Check continuity of main burner coil in gas valve. Remove wire connector. If there

 

 

is no continuity, replace valve.

 

 

 

Flame height adjustment will

Ensure the black and red leads from the battery pack or the AF4000 110H/L module

not work/works backwards

are securely connected to the red and black leads from the motor drive located on

 

 

the valve body (red to red and black to black).

 

 

Make sure the Pulse/Continuous button on the Power Module is set to Continu-

 

 

ous mode. If flame does not continuously change (increase or decrease in size)

 

 

while holding down the ON H/L button, the power module mode must be changed.

 

 

Hold down the Pulse/Continuous button on the Power Module for 2 to 3 seconds to

 

 

change mode from pulse to continuous. Re-try flame adjustment.

 

 

Check functionality with all transmitters to determine if there is an issue with the

 

 

main control system or an individual transmitter. If the issue is with an individual

 

 

transmitter, make sure the batteries in both the transmitter and receiver are in-

 

 

stalled in the proper direction and are not drained. Individual battery voltage should

 

 

be no less than 1.4V for AA and AAA batteries, 2.8V for button cells, and 9.0V for

 

 

12V batteries.

 

 

 

Room temperature dis-

Ensure the transmitter was not recently stored in a different environment (air-condi-

played on handheld trans-

tioned, heated) from that in which the transmitter is being tested. It may take up to 3

mitter is not correct.

hours for the temperature inside a packaged transmitter, and several minutes for an

(When using thermostatic

unpackaged transmitter, to equalize with the room temperature.

transmitters only)

 

 

 

Unit will not respond in THERMO mode.

(When using thermostatic transmitters only)

Ensure the thermostatic transmitter is within the 20’ operational range.

Make sure an ON or OFF command was not last sent from another transmitter. These commands will override the thermal commands from the handheld transmit- ter. To return the system to THERMO mode, press either ON or OFF on the ther- mostatic transmitter, then press the MODE button to put the system in THERMO mode. Press and hold the SET button to change the set temperature.

Verify the set temperature on the thermostatic remote is at least 2 degrees above or below the room temperature. The system will not react to temperatures within 2 degrees of the set temperature.

20011957

37

Image 37
Contents What to do if YOU Smell GAS INSTALLER/CONSUMER Safety InformationTable of Contents Certified To Installation & Operating InstructionsAnsi Z21.50b-2005 / CSA 2.22b-2005 Vented Gas Fireplace Please Review the Following CarefullyClear of ALL Obstructions Requirements for the Commonwealth of MassachusettsGas Equipment Venting System not Provided Standard Framing Locating Your FireplaceMantels Clearance to CombustiblesFraming and Finishing HearthFinal Finishing Gas Specifications Gas Line InstallationGas Inlet and Manifold Pressures High ElevationsControl System Control System InstallationInside view of wireless wall switch Special Feature for Cold ClimatesKey Settings Hand-Held Remote Control Transmitter Operating InstructionsIntroduction LCD Liquid Crystal DisplayThermostat Function Manual FunctionCP Childproof Feature Continuous Pilot FeatureSetting LOCK-OUT CP Operational Notes Thermostatic Updating FeatureLocation of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2USA Installations Canadian InstallationsGeneral Information Assembling Vent Pipes SK8 Venting Pipes Vertical Termination Horizontal TerminationSidewall Applications Step Sidewall InstallationZero clearance sleeve is only required for combustible walls Always install horizontal venting on a level planeHorizontal length requirement Sidewall Installation with Stationary Glass Facing OutsideInstalling the 38S2VDK Door Installation ProcedureRestrictor Plate Installation Flue Restrictor Plate InstallationFlue Restrictor Plate Guide Typical ApplicationsFlue restrictor plate use in straight up installation + 2 + 3 + 4 = Vertical Through-the-Roof InstallationMin Component Description Model Number Chimney ComponentsGlass Cleaning Glass Frame Assembly RemovalCeramic Refractory Installation Clean the glass after the first two weeks of operationDVT38Sw log identification Log, Lava Rock and Ember PlacementLog Pilot Plumbing F50 Overlay is very fragile Log Right Flame Characteristics Trim Installation Lighting Instructions Lighting & Operating InstructionsTurning Off the Gas to the Appliance American Flame Gas Control System TroubleshootingOperation Troubleshooting American Flame Gas Control System What to Check American Flame Gas Control System Error CodesConversion Procedure Conversion PrecautionsFuel Conversion Instructions Remove pilot orifice DVT38S2 Injector Orifice Size Matrix Pilot Flame AdjustmentValve Minimum Rate Screw Conversion to LPCleaning the Control System MaintenanceBurner and Burner Compartment DVT38S2 Units GFYW5Q0 DVT38S2 DVT38S2Fuel Conversion Kits Back-up Battery Kit AccessoriesWall Mountable Wireless Remote Transmitter Product Covered by this Warranty Limited Lifetime WarrantyModel EnerGuide Ratings Fireplace Efficiency % Efficiency Ratings