Vermont Casting DTV38s2 installation instructions Control System Installation

Page 9

Control System

The gas control system is located on the right hand side of the firebox behind an access panel and the decora- tive brick panel. The fireplace is operated using only the hand held remote control unit. The system wiring diagram is shown in Figure 11. NOTE: If you choose to install the either the optional battery back-up module, (Model DVTBBK), or the optional wireless wall mountable remote control, (Part #20012267),

it is easier to install these at the time of fireplace installation. Refer to Items #11 & #20 in the next section.

Control System Installation

1.Locate the fireplace in the desired location.

2.Remove the glass. Refer to Glass Frame Assembly Removal section.

3.If installed, remove the lava rock, volcanic rock, and- irons, embers and logs, making note of each log’s location.

4.If installed, remove the refractory brick panel right side and rear pieces.

5.Using a back-up wrench, disconnect the gas supply fitting near the right rear corner of the firebox. (Fig. 7)

Cover

Plate

Gas Sup- ply Fitting

FP1801

Fig. 7 Disconnect gas supply fitting and remove 13 screws securing the cover plate.

6.Remove pilot assembly from burner assembly by removing two (2) screws.

7.Carefully slide the burner assembly to the left out of the way, taking care not to bend or break the pilot tubes or wiring.

8.Remove 13 screws around the perimeter holding large access panel on the right hand side of the firebox.

Chateau™ Direct Vent Gas Fireplace

Gas Supply

Fitting

Pressure

Learn Button

Test

 

Ports

 

FP1802

Fig. 8 Connect gas supply to valve.

9.Carefully pull back the panel just enough to gain ac- cess to control box.

10.Connect the gas supply to the valve. (Fig. 8) Be sure to use a back-up wrench when tightening supply fitting.

11.If you chose to install the optional back-up battery pack (No. DVTBBK), you must install a wall box within 15 feet (4.6 m) of the fireplace. Assemble the connectors on one end of the supplied extension wire harness to the mating connectors on the wire harness within the control box. Make sure to connect black coded wire to black and red coded wire to red.

12.The other end of the extension wire harness should be connected to the wiring of the back-up battery holder located within a wall box.

13.Insert the supplied four (4) “AA” batteries into the battery older. Be sure to note correct polarity for each battery.

14.Mount electrical wall box containing back-up bat- teries at a convenient location with 15 feet (4.6 m) of the fireplace. Cover wall box using a blank wall plate.

15.Connect a 120V AC electrical supply to the junction box duplex outlet. Use a Romex-type strain relief connector when running wires out through the box knockout. Replace the duplex outlet and cover plate.

16.Plug the AC adaptor plug into the duplex outlet.

17.This control must now be programmed to the re- mote control transmitter(s). To program the remote control(s), make sure the 120V AC is connected and powered to the fireplace.

18.Remove the battery door on the back of the hand held remote control and install two (2) supplied “AAA” batteries. Be sure to note correct polarity. Replace battery door.

20011957

9

Image 9
Contents What to do if YOU Smell GAS INSTALLER/CONSUMER Safety InformationTable of Contents Certified To Installation & Operating InstructionsAnsi Z21.50b-2005 / CSA 2.22b-2005 Vented Gas Fireplace Please Review the Following CarefullyRequirements for the Commonwealth of Massachusetts Clear of ALL ObstructionsGas Equipment Venting System not Provided Standard Framing Locating Your FireplaceMantels Clearance to CombustiblesHearth Framing and FinishingFinal Finishing Gas Specifications Gas Line InstallationGas Inlet and Manifold Pressures High ElevationsControl System Control System InstallationInside view of wireless wall switch Special Feature for Cold ClimatesKey Settings Hand-Held Remote Control Transmitter Operating InstructionsIntroduction LCD Liquid Crystal DisplayThermostat Function Manual FunctionContinuous Pilot Feature CP Childproof FeatureSetting LOCK-OUT CP Operational Notes Thermostatic Updating FeatureLocation of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2Canadian Installations USA InstallationsGeneral Information Assembling Vent Pipes SK8 Venting Pipes Horizontal Termination Vertical TerminationSidewall Applications Step Sidewall InstallationZero clearance sleeve is only required for combustible walls Always install horizontal venting on a level planeHorizontal length requirement Sidewall Installation with Stationary Glass Facing OutsideInstalling the 38S2VDK Door Installation ProcedureRestrictor Plate Installation Flue Restrictor Plate InstallationFlue Restrictor Plate Guide Typical ApplicationsFlue restrictor plate use in straight up installation + 2 + 3 + 4 = Vertical Through-the-Roof InstallationMin Component Description Model Number Chimney ComponentsGlass Cleaning Glass Frame Assembly RemovalCeramic Refractory Installation Clean the glass after the first two weeks of operationDVT38Sw log identification Log, Lava Rock and Ember PlacementLog Pilot Plumbing F50 Overlay is very fragile Log Right Flame Characteristics Trim Installation Lighting & Operating Instructions Lighting InstructionsTurning Off the Gas to the Appliance Troubleshooting American Flame Gas Control SystemOperation Troubleshooting American Flame Gas Control System What to Check American Flame Gas Control System Error CodesConversion Precautions Conversion ProcedureFuel Conversion Instructions Remove pilot orifice DVT38S2 Injector Orifice Size Matrix Pilot Flame AdjustmentValve Minimum Rate Screw Conversion to LPMaintenance Cleaning the Control SystemBurner and Burner Compartment DVT38S2 Units GFYW5Q0 DVT38S2 DVT38S2Fuel Conversion Kits Accessories Back-up Battery KitWall Mountable Wireless Remote Transmitter Product Covered by this Warranty Limited Lifetime WarrantyModel EnerGuide Ratings Fireplace Efficiency % Efficiency Ratings