Vermont Casting DTV38s2 American Flame Gas Control System Error Codes, What to Check

Page 38

Chateau™ Direct Vent Gas Fireplace

American Flame Gas Control System Error Codes

Ignition Safety: Protection for Ignition System

Error Code: One beep every one second

Description of Fault: Warn users if the pilot is not successfully ignited in 60 seconds.

How to Clear: Press OFF then ON buttons to re-attempt ignition.

What to Check:

Ensure gas supply is turned on.

Ensure orange/white leads from module are plugged into the “PILOT” connection on the valve body.

Verify the lead from igniter on pilot assembly is connected to the “I” terminal on the module.

Verify lead from flame sensor on pilot assembly is connected to the “S” terminal on the module.

Verify that the black ground lead form the module is connected to a proper ground on the fireplace.

Ensure there is no blockage in the pilot line.

Sensor Safety: Protection for Flame Sensor

Error Code: 4 beeps every one second

Description of Fault: Warn users the pilot flame sensor detects a pilot flame already present when ignition sequence is initiated. This fault will also occur if pilot flame sensor is shorted to ground.

How to Clear: Press OFF then ON buttons to re-attempt normal ignition.

What to Check:

Check if pilot flame is actually present when valve is turned OFF (valve replacement necessary if yes).

Replace pilot assembly.

Replace module.

Thermal Safety: Overheat Protection

Error Code: 4 beeps every two seconds.

Description of Fault: Warn users that the module’s internal temperature has exceeded 170° F (77° C).

How to Clear: Module’s internal temperature must cool to below 160° F (71° C) and then press ON button.

What to Check:

Is module located in unapproved location, too close to burner?

Move to cooler location.

Communication Safety: (NOTE: This feature is only available when transmitter includes an LCD screen).

Error Code: One beep every four seconds.

Description of Fault: Warn users that the transmitter and receiver are not communicating properly.

What to Check:

Verify batteries in both transmitter and receiver are new.

Ensure transmitter is located within 20 feet (6 m) of receiver.

Ensure transmitter is not placed in metal enclosure or laying directly on top of a metal surface as this can interfere with transmission.

38

20011957

Image 38
Contents INSTALLER/CONSUMER Safety Information What to do if YOU Smell GASTable of Contents Ansi Z21.50b-2005 / CSA 2.22b-2005 Vented Gas Fireplace Installation & Operating InstructionsCertified To Please Review the Following CarefullyGas Equipment Venting System not Provided Requirements for the Commonwealth of MassachusettsClear of ALL Obstructions Locating Your Fireplace Standard FramingClearance to Combustibles MantelsFinal Finishing HearthFraming and Finishing Gas Inlet and Manifold Pressures Gas Line InstallationGas Specifications High ElevationsControl System Installation Control SystemSpecial Feature for Cold Climates Inside view of wireless wall switchIntroduction Hand-Held Remote Control Transmitter Operating InstructionsKey Settings LCD Liquid Crystal DisplayManual Function Thermostat FunctionSetting LOCK-OUT CP Continuous Pilot FeatureCP Childproof Feature Thermostatic Updating Feature Operational NotesGeneral Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationGeneral Information Assembling Vent Pipes SK8 Venting Pipes Canadian InstallationsUSA Installations Sidewall Applications Horizontal TerminationVertical Termination Sidewall Installation StepAlways install horizontal venting on a level plane Zero clearance sleeve is only required for combustible wallsSidewall Installation with Stationary Glass Facing Outside Horizontal length requirementInstallation Procedure Installing the 38S2VDK DoorFlue Restrictor Plate Guide Flue Restrictor Plate InstallationRestrictor Plate Installation Typical ApplicationsFlue restrictor plate use in straight up installation Vertical Through-the-Roof Installation + 2 + 3 + 4 =Min Chimney Components Component Description Model NumberCeramic Refractory Installation Glass Frame Assembly RemovalGlass Cleaning Clean the glass after the first two weeks of operationLog, Lava Rock and Ember Placement DVT38Sw log identificationLog Pilot Plumbing F50 Overlay is very fragile Log Right Flame Characteristics Trim Installation Turning Off the Gas to the Appliance Lighting & Operating InstructionsLighting Instructions Operation TroubleshootingAmerican Flame Gas Control System Troubleshooting American Flame Gas Control System American Flame Gas Control System Error Codes What to CheckFuel Conversion Instructions Conversion PrecautionsConversion Procedure Remove pilot orifice Valve Minimum Rate Screw Pilot Flame AdjustmentDVT38S2 Injector Orifice Size Matrix Conversion to LPBurner and Burner Compartment MaintenanceCleaning the Control System DVT38S2 Units GFYW5Q0 DVT38S2 DVT38S2Fuel Conversion Kits Wall Mountable Wireless Remote Transmitter AccessoriesBack-up Battery Kit Limited Lifetime Warranty Product Covered by this WarrantyEfficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %