CarAlarms.com P90-NG1 manual Installation of the DC Sparker for the H35-1 Units Only

Page 26

INSTALLATION

14)Using the Allen wrench as shown in Fig.4, rotate the screw clockwise until snug, do not overtighten.

Fig.4

WARNING!

Do not overtighten the screw. Recommended to

grip the wrench by the short side.

15) Verify that if the conversion is from NG to LPG, the screw must be reassembled with the red o-ring visible (Fig. 5).

17) Reverse steps 4) to 2).

4) Attach the DC sparker generator

 

connector to the valve with a screw.

18)Attach clear label "This unit has been converted to LPG" near or on top of the serial # decal.

19)Replace yellow "Natural Gas" label with red "LPG" label.

Installation of the DC Sparker for the H35-1 Units Only:

1)Remove the control panel by unscrewing the 2 screws.

5) Remove the stove’s rear panel by unscrew- ing the two screws.

Red o-ring visible

Fig.5

LPG Configuration

2)First, remove the Piezo Ignition Wire from the Piezo Ignitor. Then remove the Piezo Ignitor from the control panel.

6) Attach the ground wire to the grounding stud.

16) Reassemble the black protection cap (Fig. 6).

3)Plug up the Piezo hole with the plastic bushing.

Before

Fig. 6

WARNING!

Also check that the pilot and main

burner injectors

are appropriate for the gas type.

After

26

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace

Image 26
Contents P90 Zero Clearance Direct Vent Gas Fireplace 07/17/06Information for MOBILE/MANUFACTURED Homes After First Sale To the New OwnerTable of Contents Safety Label Copy of Safety Decal for P90Requirements For the State of Massachusetts onlyInstallation Checklist InstallationGeneral Safety Information Important Message Save These InstructionsHeatwave Locating Your GAS FireplaceManufactured Mobile Home Additional Requirements Optional Heat Release KITFraming Finishing Framing DimensionsCombustible Mantels Unit Base STAND-OFFSFloor Mounted Fireplaces Raised Fireplaces Facing RequirementFacing Over 1 25mm Thick Venting Introduction Unit Assembly Prior to InstallationTop Standoff Assembly Side Nailing StripsVenting FPI Direct Vent System Flex Horizontal Terminations OnlyExterior Vent Termination Locations Rigid Pipe Venting Components List SV4LB6Horizontal Rigid Pipe Venting SystemsAlternate CapsHorizontal & Vertical Terminations for 5 x 8 Venting Rigid Pipe Venting Arrangements Horizontal Terminations 8 outer diameterRigid Pipe Venting Arrangements Vertical Terminations Installation Option + H1 Horizontal Venting with Two 2 90o ElbowsHorizontal Venting with Three 3 90o Elbows Option + V1 H + H1Option Vertical Venting with Two 2 90o ElbowsVertical Venting with Three 3 90o Elbows Horizontal Terminations Below Grade InstallationDiagram This allows for small adjustments Vertical Terminations For FPI Direct Vent System Flex Installation Procedures Offset Chart GAS Pipe Pressure Testing Pilot AdjustmentGAS Line Installation High ElevationConversion KIT #791-969 from NG to LP LPG Conversion Kit Contains Qty DescriptionInstallation of the DC Sparker for the H35-1 Units Only Installation of the DC Sparker For the P90 Units Only Ground Wire from Kit 2nd Grate Tab 02-75 02-54 02-52 02-50 02-53 02-51Bracket 02-53Front Brackets 02-5302-5102-50 02-53 Place embers in these 3 locations On the burner trayOptional Screen Door Glass Door InstallationArch Surround Screw BracketAccent KIT Installation Double & Single Door OptionThermostat Wire Table Remote ControlWall Switch Wall ThermostatWiring Diagrams Do not cut the ground terminal off under any circumstancesFor Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Copy of the Lighting Plate Instructions Normal Operating Sounds of GAS AppliancesMaintenance Shut the power off FAN MaintenanceTo Install the Fan To Remove the FanHint Installing ValveRemoving Valve ImpossibleDescription Parts ListP90 Main Assembly Heat Wave Duct KIT P90 Burner Assembly & LOG SET P90 Flush Front Accessories DescriptionExcalibur P90 Zero Clearance Direct Vent Gas Fireplace Excalibur P90 Zero Clearance Direct Vent Gas Fireplace Warranty Warranty Limited LifetimeInstaller Please complete the following information