MAINTENANCE

Unit must be grounded at all times. Do not cut the ground terminal off under any circumstances.

To Install the Fan

1)Shut the power off.

2)Open the bottom louver door. Loosen the 2 screws holding the Burner ON/OFF switch and bracket to the bottom louver and lift the assembly out.

3)Remove the bottom louver door.

4)Slide the fan in towards the rear of the unit and slip it over the two mounting studs. Take care not to damage the insulation on the fan base. Ensure that the fan blades do not rub against the valve tubing. Diagram 1.

Diagram 1

5)Connect fan ground cable to ground lug. Refer to wiring diagram.

6)Slide the thermodisc/cover assembly into the bracket clip on the underside of the fi rebox. Check that no wire will touch the hot surfaces. Diagram 2.

FAN MAINTENANCE

Diagram 2

7)Attach the two control boxes to the bottom unit base and tighten the 2 screws on the left side and 1 screw on the right side.

Secure left side with 2 screws and right side

with one screw.

8)Secure the fan wires and power cord by attaching one of the adhesive backed wire holder clips (Part #910-199) onto the stove base. Use the second clip to bundle up the wires approximately 4" from the control box. Ensure that there is no interference with the wires when the louver is closed and that no wire will touch the hot metal surfaces or sharp edges.

9)Plug the fan power cord into the rear end of the receptacle box to provide the maximum clearance from the louvers.

To Remove the Fan

1)Shut the power off.

2)Reverse the above instructions.

Note: The bearings are lubricated for life. Do not lubricate them. Make sure you vacuum the fan area on a regular basis.

IMPORTANT:

These fans collect a lot of dust from within your home. Ensure you maintain these fan motors on a regular basis by vacuuming out the fan blades and housing using a soft brush nozzle.

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace

39

Image 39
Contents 07/17/06 P90 Zero Clearance Direct Vent Gas FireplaceTo the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Copy of Safety Decal for P90 Safety LabelFor the State of Massachusetts only RequirementsImportant Message Save These Instructions InstallationGeneral Safety Information Installation ChecklistOptional Heat Release KIT Locating Your GAS FireplaceManufactured Mobile Home Additional Requirements HeatwaveUnit Base STAND-OFFS Framing DimensionsCombustible Mantels Framing FinishingFacing Requirement Facing Over 1 25mm ThickFloor Mounted Fireplaces Raised Fireplaces Side Nailing Strips Unit Assembly Prior to InstallationTop Standoff Assembly Venting IntroductionFPI Direct Vent System Flex Horizontal Terminations Only VentingExterior Vent Termination Locations SV4LB6 Rigid Pipe Venting Components ListCaps Rigid Pipe Venting SystemsAlternate HorizontalHorizontal & Vertical Terminations for 5 x 8 Venting 8 outer diameter Rigid Pipe Venting Arrangements Horizontal TerminationsRigid Pipe Venting Arrangements Vertical Terminations Installation Option + V1 H + H1 Horizontal Venting with Two 2 90o ElbowsHorizontal Venting with Three 3 90o Elbows Option + H1Vertical Venting with Two 2 90o Elbows Vertical Venting with Three 3 90o ElbowsOption Below Grade Installation DiagramHorizontal Terminations Vertical Terminations This allows for small adjustmentsInstallation Procedures Offset ChartFor FPI Direct Vent System Flex High Elevation Pilot AdjustmentGAS Line Installation GAS Pipe Pressure TestingLPG Conversion Kit Contains Qty Description Conversion KIT #791-969 from NG to LPInstallation of the DC Sparker for the H35-1 Units Only Installation of the DC Sparker For the P90 Units Only Ground Wire from Kit 02-53 02-75 02-54 02-52 02-50 02-53 02-51Bracket 2nd Grate TabPlace embers in these 3 locations On the burner tray 02-5302-5102-50 02-53 Front BracketsScrew Bracket Glass Door InstallationArch Surround Optional Screen DoorDouble & Single Door Option Accent KIT InstallationWall Thermostat Remote ControlWall Switch Thermostat Wire TableDo not cut the ground terminal off under any circumstances Wiring DiagramsFor Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Normal Operating Sounds of GAS Appliances Copy of the Lighting Plate InstructionsMaintenance To Remove the Fan FAN MaintenanceTo Install the Fan Shut the power offImpossible Installing ValveRemoving Valve HintParts List P90 Main AssemblyDescription Heat Wave Duct KIT P90 Burner Assembly & LOG SET Description P90 Flush Front AccessoriesExcalibur P90 Zero Clearance Direct Vent Gas Fireplace Excalibur P90 Zero Clearance Direct Vent Gas Fireplace Warranty Limited Lifetime WarrantyInstaller Please complete the following information

P90-NG1 specifications

CarAlarms.com P90-NG1 is a cutting-edge vehicle security system designed to provide maximum protection against theft and unauthorized access. This advanced system combines innovative technology with user-friendly features to ensure that car owners can safeguard their vehicles effectively.

One of the standout features of the P90-NG1 is its two-way communication system. This allows users to receive real-time alerts and notifications directly on their key fob whenever the system detects any suspicious activity. The LCD display on the key fob provides clear information, including the vehicle's status, which enhances the overall user experience. This feature ensures that users are always informed about their vehicle’s security status, whether they are close by or a significant distance away.

The P90-NG1 also employs a state-of-the-art shock sensor, which detects impacts on the vehicle's body. This allows the system to respond swiftly to attempted break-ins or vandalism, triggering an audible alarm to deter potential thieves. The adjustable sensitivity of the shock sensor can be customized to suit different environments, ensuring that users can find an optimal balance between security and everyday usability.

Another notable characteristic of the P90-NG1 is its remote start capability. This feature enables users to start their vehicle from afar, adding convenience, especially in harsh weather conditions. Paired with the optional smartphone app, users can control their vehicle’s security functions from their mobile devices, providing added flexibility and peace of mind.

The installation process of the P90-NG1 is designed to be straightforward and efficient, making it suitable for a wide range of vehicles. The system is compatible with various vehicle models and can be integrated seamlessly with existing systems, providing enhanced functionality without compromising factory features.

In conclusion, CarAlarms.com P90-NG1 stands out in the vehicle security market due to its robust features, advanced technology, and user-centric design. With its reliable two-way communication, effective shock sensor, and convenient remote start capability, it offers vehicle owners a comprehensive solution to protect their assets while ensuring ease of use. This makes the P90-NG1 an ideal choice for those looking to enhance the security of their vehicles.