CarAlarms.com P90-NG1 manual Ground Wire from Kit

Page 28

INSTALLATION

5)Connect the DC spark generator wires to the SIT Valve with the screw, which is provided in the kit.

6)Locate the ground lug at the receptical box, left of the unit.

7)Connect one end of the supplied green ground wire to the lug with the nut and washer from the kit.

Ground

wire from

kit

9)Run the other end of the ground wire and DC spark generator wires through the bushing on the heat shield.

Heat Shield

10)Plug the DC spark generator wires to the DC Sparker.

11)Connect the ground wire to the DC Sparker mounting bracket.

13)Mount the heat shield to the DC Sparker. Secure into place with the velcro, which is provided in the kit.

14)Find a location which is not too hot and is easy to reach for changing the battery.

15)Tie up the loose wire with the wire clip.

16)Check for gas leaks.

17)Check inlet and outlet pressures.

18)Check operation of fl ame control.

19)Check for proper fl ame appearance and glow on logs.

Installer Notice:

These instructions must be left with the appliance.

8)Install the 1/2" bushing to the heat shield.

12)Install the supplied battery into the DC Sparker Box by opening the battery compartment.

NOTE: The battery in the DC Sparker Box will need to be replaced annually.

Battery

Compartment

28

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace

Image 28
Contents P90 Zero Clearance Direct Vent Gas Fireplace 07/17/06Information for MOBILE/MANUFACTURED Homes After First Sale To the New OwnerTable of Contents Safety Label Copy of Safety Decal for P90Requirements For the State of Massachusetts onlyInstallation General Safety InformationInstallation Checklist Important Message Save These InstructionsLocating Your GAS Fireplace Manufactured Mobile Home Additional RequirementsHeatwave Optional Heat Release KITFraming Dimensions Combustible MantelsFraming Finishing Unit Base STAND-OFFSFacing Over 1 25mm Thick Facing RequirementFloor Mounted Fireplaces Raised Fireplaces Unit Assembly Prior to Installation Top Standoff AssemblyVenting Introduction Side Nailing StripsVenting FPI Direct Vent System Flex Horizontal Terminations OnlyExterior Vent Termination Locations Rigid Pipe Venting Components List SV4LB6Rigid Pipe Venting Systems AlternateHorizontal CapsHorizontal & Vertical Terminations for 5 x 8 Venting Rigid Pipe Venting Arrangements Horizontal Terminations 8 outer diameterRigid Pipe Venting Arrangements Vertical Terminations Installation Horizontal Venting with Two 2 90o Elbows Horizontal Venting with Three 3 90o ElbowsOption + H1 Option + V1 H + H1Vertical Venting with Three 3 90o Elbows Vertical Venting with Two 2 90o ElbowsOption Diagram Below Grade InstallationHorizontal Terminations This allows for small adjustments Vertical TerminationsOffset Chart Installation ProceduresFor FPI Direct Vent System Flex Pilot Adjustment GAS Line InstallationGAS Pipe Pressure Testing High Elevation Conversion KIT #791-969 from NG to LP LPG Conversion Kit Contains Qty DescriptionInstallation of the DC Sparker for the H35-1 Units Only Installation of the DC Sparker For the P90 Units Only Ground Wire from Kit 02-75 02-54 02-52 02-50 02-53 02-51 Bracket2nd Grate Tab 02-5302-5302-51 02-50 02-53Front Brackets Place embers in these 3 locations On the burner trayGlass Door Installation Arch SurroundOptional Screen Door Screw BracketAccent KIT Installation Double & Single Door OptionRemote Control Wall SwitchThermostat Wire Table Wall ThermostatWiring Diagrams Do not cut the ground terminal off under any circumstancesFor Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Copy of the Lighting Plate Instructions Normal Operating Sounds of GAS AppliancesMaintenance FAN Maintenance To Install the FanShut the power off To Remove the FanInstalling Valve Removing ValveHint ImpossibleP90 Main Assembly Parts ListDescription Heat Wave Duct KIT P90 Burner Assembly & LOG SET P90 Flush Front Accessories DescriptionExcalibur P90 Zero Clearance Direct Vent Gas Fireplace Excalibur P90 Zero Clearance Direct Vent Gas Fireplace Warranty Warranty Limited LifetimeInstaller Please complete the following information