CarAlarms.com P90-NG1 manual Safety Label, Copy of Safety Decal for P90

Page 4
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE Serial No./ No de serie

4

The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed.

For the State of Massachusetts, the appli- ances individual manual shut-off must be a t-handle type valve.

For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.

For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the Commonwealth of Massachusetts.

 

 

 

 

Copy of Safety Decal for P90

Duplicate S/N

NOTE: Excalibur® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.

This is a copy of the label that accompanies each P90 Zero Clearance Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit, visible when the bottom louver is open.

309

SAFETY LABEL

Listed: VENTED GAS FIREPLACE HEATER

Certified for/Certifiée pour: CANADA and U.S.A.

Tested to: Gas-Fired Appliances For Use At High Altitudes CAN/CGA-2.17-M91,

Vented Gas Fireplace Heaters ANSI Z21.88b-2003/CSA 2.33b-2003309 Report No. 476-3059100 (June 2004)

Excalibur

P90- Model/M NG1 odele:

NATURAL GAS: Model P90-NG1

 

 

APPAREIL FONCTIONNANT AU NATURAL GAZ

L

 

 

 

CONCU POUR ETRE POELE: Modéle P90-NG1

Minimum supply pressure

5"

WC(1.25 kPa)

Pression d'allimentation minimum

Manifold pressure high

3.8"

WC(0.95 kPa)

Pression à la tubulure d'échappement élevée

Manifold pressure low

1.1"

WC(0.27 kPa)

Pression à la tubulure d'échappement basse

Orifice size

# 34

DMS

 

Grandeur de l'injecteur

Minimum input

18,200

Btu/h

(5.42 kW)

Débit Calorifique minimum selon

Maximum input

35,000

Btu/h

(10.26 kW)

Débit Calorifique maximum selon

Altitude

0-4500

ft/pi

(0-1372 m)

l'altitude

PROPANE: Model P90-LP1

 

 

APPAREIL FONCTIONNANT AU GAZ PROPANE

MAY BE INSTALLED IN MANUFACTURED (MOBILE)

HOMES AFTER FIRST SALE.

Minimum Clearances to Combustibles

/Degagement Minimum De Materiaux Combustibles

44-1/4" To Ceiling

0" Clearance to

 

 

 

combustibles from:

 

 

18-1/4"

Top, bottom, sides & rear of unit

 

 

Mantel Clearances from Top:

 

 

 

Min. 18-1/4" (464mm)

 

 

 

® P90 Zero Clearance Direct

P90- Model/M LP1 odele:

L

 

 

 

CONCU POUR ETRE POELE: Modéle P90-LP1

Minimum supply pressure

12"

WC(3.00 kPa)

Pression d'allimentation minimum

Manifold pressure high

11"

WC(2.74 kPa)

Pression à la tubulure d'échappement élevée

Manifold pressure low

2.9"

WC(0.72 kPa)

Pression à la tubulure d'échappement basse

Altitude

0-2000

ft/pi

(0-610 m)

l'altitude

Orifice size

# 51

DMS

 

Grandeur de l'injecteur

Minimum input

17,950

Btu/h

(5.26 kW)

Débit Calorifique minimum selon

Maximum input

35,000

Btu/h

(10.26 kW)

Débit Calorifique maximum selon

High Altitude

2000-4500 ft/pi (610-1372 m) l'altitude

Orifice size

# 52

DMS

 

Grandeur de l'injecteur

Minimum input

15,500

Btu/h

(4.54 kW)

Débit Calorifique minimum selon

Maximum input

31,000

Btu/h

(9.08 kW)

Débit Calorifique maximum selon

Wall

6-1/2"

 

 

 

 

 

6-1/2"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DOOR SEAL: Please check that the door is properly sealed

Wall

Side Wall Clearance

from Side Facing

 

6-1/2" (165mm)

Alcove Clearances:

Max. Depth 36" (914mm)

Min. Width 48" (1219mm),

Min. Height 72" (1229mm)

Minimum Vent Clearances:

Horizontal Top

2-1/2" (64mm)

Horizontal Side

1-1/2" (38mm)

Horizontal Bottom

1-1/2" (38mm)

(See Instruction Manual for

Detailed Instructions)

Vent Gas Fireplace

VENTING: This appliance must be installed in accordance with the manufacturer's installation instructions and with local codes, if any; if not, follow the current ANSI Z223.1 in the USA or

the current CAN 1-B149 in Canada. For Manufactured Home Installation: This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI /NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada. Optional Fan (Part # 432-917) Optional Heat Wave Kit # 946-556 Optional Heat Release Kit # 946-570. Electrical supply 115VAC, 1.13 A, 60Hz.

Not for use with solid fuel. This vented gas fireplace is not for use with filters. For horizontal runs exceeding 10’, 5” x 8” piping must be used.

Made in Canada/ Fabrique au Canada

FPI Fireplace Products International Ltd. Delta, BC, Canada

918--503

Image 4
Contents P90 Zero Clearance Direct Vent Gas Fireplace 07/17/06Information for MOBILE/MANUFACTURED Homes After First Sale To the New OwnerTable of Contents Safety Label Copy of Safety Decal for P90Requirements For the State of Massachusetts onlyInstallation General Safety InformationInstallation Checklist Important Message Save These InstructionsLocating Your GAS Fireplace Manufactured Mobile Home Additional RequirementsHeatwave Optional Heat Release KITFraming Dimensions Combustible MantelsFraming Finishing Unit Base STAND-OFFSFacing Over 1 25mm Thick Facing RequirementFloor Mounted Fireplaces Raised Fireplaces Unit Assembly Prior to Installation Top Standoff AssemblyVenting Introduction Side Nailing StripsVenting FPI Direct Vent System Flex Horizontal Terminations OnlyExterior Vent Termination Locations Rigid Pipe Venting Components List SV4LB6Rigid Pipe Venting Systems AlternateHorizontal CapsHorizontal & Vertical Terminations for 5 x 8 Venting Rigid Pipe Venting Arrangements Horizontal Terminations 8 outer diameterRigid Pipe Venting Arrangements Vertical Terminations Installation Horizontal Venting with Two 2 90o Elbows Horizontal Venting with Three 3 90o ElbowsOption + H1 Option + V1 H + H1Vertical Venting with Three 3 90o Elbows Vertical Venting with Two 2 90o ElbowsOption Diagram Below Grade InstallationHorizontal Terminations This allows for small adjustments Vertical TerminationsOffset Chart Installation ProceduresFor FPI Direct Vent System Flex Pilot Adjustment GAS Line InstallationGAS Pipe Pressure Testing High ElevationConversion KIT #791-969 from NG to LP LPG Conversion Kit Contains Qty DescriptionInstallation of the DC Sparker for the H35-1 Units Only Installation of the DC Sparker For the P90 Units Only Ground Wire from Kit 02-75 02-54 02-52 02-50 02-53 02-51 Bracket2nd Grate Tab 02-5302-5302-51 02-50 02-53Front Brackets Place embers in these 3 locations On the burner trayGlass Door Installation Arch SurroundOptional Screen Door Screw BracketAccent KIT Installation Double & Single Door OptionRemote Control Wall SwitchThermostat Wire Table Wall ThermostatWiring Diagrams Do not cut the ground terminal off under any circumstancesFor Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Copy of the Lighting Plate Instructions Normal Operating Sounds of GAS AppliancesMaintenance FAN Maintenance To Install the FanShut the power off To Remove the FanInstalling Valve Removing ValveHint ImpossibleP90 Main Assembly Parts ListDescription Heat Wave Duct KIT P90 Burner Assembly & LOG SET P90 Flush Front Accessories DescriptionExcalibur P90 Zero Clearance Direct Vent Gas Fireplace Excalibur P90 Zero Clearance Direct Vent Gas Fireplace Warranty Warranty Limited LifetimeInstaller Please complete the following information