INSTALLATION
CONVERSION KIT #791-969 FROM NG TO LP
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
Each Kit contains one LPG Conversion Kit and one DC Sparker Kit.
LPG Conversion Kit Contains:
Qty. Part # | Description | |
1 | 5/32" Allen Key | |
1 | Burner Orifi ce #51 |
1
1 | Red "LPG" label | |
1 | LP Injector (Pilot Orifi ce) | |
1 | Instruction Sheet | |
DC Sparker Kit Contains: | ||
Qty. Part # | Description | |
1 | Bracket DC Sparker | |
1 | Bracket DC Sparker | |
1 | Washer #8 External Star | |
1 | Nut |
1
1
0.500 in.
1
2
Black Oxide
1 | Spark Generator Battery | |
|
| Holder |
1
1
2
1
Installation of LPG
Conversion Kit:
1)Shut off the gas supply.
2)
3)Remove the logs, embers, and brick panels (if used).
4)Remove the 2 screws holding the Burner Assembly to the fi rebox base. Push the Burner Assembly to the left and lift out.
Remove the 2 screws, push Burner
Assembly to the left and lift out.
5)Pull off the pilot cap to expose the pilot orifi ce.
6)Unscrew the pilot orifi ce with the allen key and replace with the LP pilot orifi ce in the kit and replace pilot cap.
7)Remove burner orifi ce with a 1/2" wrench and discard. Use another wrench to hold on to the elbow behind the orifi ce.
Burner Orifi ce
8)Reinstall new burner orifi ce LP stamped #51 and tighten.
9) Turn control knob to the “OFF” position.
10) Remove the black protection cap by hand from the
Fig. 1
11) Insert a 5/32” or 4mm Allen wrench into the hexagonal
Fig.2
12) Check that the screw is clean and if necessary remove dirt.
13) Flip the screw (Fig. 3).
Fig.3
Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace | 25 |