CarAlarms.com P90-NG1 manual Operating Instructions

Page 36

OPERATING INSTRUCTIONS

OPERATING

INSTRUCTIONS

1)Read and understand these instructions before operating this appliance.

2)Check to see that all wiring is correct and enclosed to prevent possible shock.

3)Check to ensure there are no gas leaks.

4)Make sure the glass in the door frame is properly positioned. Never operate the appliance with the glass removed.

5)Verify that the venting and cap are unobstructed.

6)Ensure that the brick panels are installed.

7)Verify log placement. If the pilot cannot be seen when lighting the unit, the logs have been incorrectly positioned.

8)The unit should never be turned off, and on again without a minimum of a 60 second wait.

LIGHTING

PROCEDURE

IMPORTANT

To ignite or reignite the pilot, remove one glass panel/door.

NOTE: For all propane units and units equipped with electric spark boxes, see "Copy of Lighting Plate Instruc- tions" section for more details.

Only when the pilot holds, without pressure being applied to the control knob, resecure the glass panel to the unit. The unit must not be operated with the glass removed.

IMPORTANT Gas on/off knob cannot be turned from "PILOT" to "OFF" unless it is partially depressed.

1)Turn burner OFF using "ON/OFF" switch.

2)Turn gas control knob so indicator points to "OFF" position and allow 5 minutes for any gas in the combustion chamber to escape.

3)Turn gas control knob counterclockwise so indicator points to the "PILOT" position. Depress the gas control knob fully. Depress the igniter button several times until the pilot lights. After approximately one minute, release the gas control knob. The pilot fl ame should continue to burn. If the pilot does not remain lit, repeat operation allowing a longer period before releasing gas control knob.

4)When the pilot stays lit, turn the gas knob further counterclockwise to the "ON" position.

5)Use the wall switch, thermostat or remote control to turn on the unit.

6)Rotate the fl ame height regulator to adjust the fl ame height higher or lower.

SHUTDOWN

PROCEDURE

1)Use the wall switch, thermostat or remote control to turn off the main burner.

2)Turn the main gas control clockwise to the "OFF" position to turn off the pilot.

3)Turn off all electric power to appliance if service is to be performed.

FIRST FIRE

The fi rst fi re in your fi replace is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your fi replace for at least four (4) hours the fi rst time before you use it with the fan on.

Whenfirstoperated,theunitwillreleaseanodour caused by the curing of the paint, the burning off of any oils remaining from manufacturing. Smoke detectors in the house may go off at this time. Open a few windows to ventilate the room for a couple of hours.

The glass panel may require cleaning after the

unit has cooled down.

DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT.

Note: When the glass is cold and the appliance is lit, it may cause condensation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up.

DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE.

During the first few fires, a white film may develop on the glass front as part of the curing process. The glass should be cleaned or the film will bake on and become very difficult to remove. Use a non-abrasive cleaner and NEVER clean the glass while it is hot.

AERATION

ADJUSTMENT

The air shutter can be adjusted by moving the adjusting wire up or down. The wire is accessed through the bottom louver opening. Open the air shutter for a blue fl ame or close for a more yellow fl ame. The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude.

Minimum Air Shutter Opening:

3/16" Natural Gas

5/16" Propane

CAUTION: Carbon will be produced if air shutter is closed too much.

Note: Any damage due to carboning resulting from improperly setting the aeration controls is NOT covered under warranty.

Adjustment Wire: Push to close or

pull to open aeration cap.

Closed - Tall yellow

Open - Short Blue

Note: Aeration Adjustment should only be performed by an authorized Excalibur® Installer at the time of installation or service.

36

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace

Image 36
Contents P90 Zero Clearance Direct Vent Gas Fireplace 07/17/06Information for MOBILE/MANUFACTURED Homes After First Sale To the New OwnerTable of Contents Safety Label Copy of Safety Decal for P90Requirements For the State of Massachusetts onlyInstallation General Safety InformationInstallation Checklist Important Message Save These InstructionsLocating Your GAS Fireplace Manufactured Mobile Home Additional RequirementsHeatwave Optional Heat Release KITFraming Dimensions Combustible MantelsFraming Finishing Unit Base STAND-OFFSFacing Requirement Facing Over 1 25mm ThickFloor Mounted Fireplaces Raised Fireplaces Unit Assembly Prior to Installation Top Standoff AssemblyVenting Introduction Side Nailing StripsVenting FPI Direct Vent System Flex Horizontal Terminations OnlyExterior Vent Termination Locations Rigid Pipe Venting Components List SV4LB6Rigid Pipe Venting Systems AlternateHorizontal CapsHorizontal & Vertical Terminations for 5 x 8 Venting Rigid Pipe Venting Arrangements Horizontal Terminations 8 outer diameterRigid Pipe Venting Arrangements Vertical Terminations Installation Horizontal Venting with Two 2 90o Elbows Horizontal Venting with Three 3 90o ElbowsOption + H1 Option + V1 H + H1Vertical Venting with Two 2 90o Elbows Vertical Venting with Three 3 90o ElbowsOption Below Grade Installation DiagramHorizontal Terminations This allows for small adjustments Vertical TerminationsInstallation Procedures Offset ChartFor FPI Direct Vent System Flex Pilot Adjustment GAS Line InstallationGAS Pipe Pressure Testing High ElevationConversion KIT #791-969 from NG to LP LPG Conversion Kit Contains Qty DescriptionInstallation of the DC Sparker for the H35-1 Units Only Installation of the DC Sparker For the P90 Units Only Ground Wire from Kit 02-75 02-54 02-52 02-50 02-53 02-51 Bracket2nd Grate Tab 02-5302-5302-51 02-50 02-53Front Brackets Place embers in these 3 locations On the burner trayGlass Door Installation Arch SurroundOptional Screen Door Screw BracketAccent KIT Installation Double & Single Door OptionRemote Control Wall SwitchThermostat Wire Table Wall ThermostatWiring Diagrams Do not cut the ground terminal off under any circumstancesFor Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Copy of the Lighting Plate Instructions Normal Operating Sounds of GAS AppliancesMaintenance FAN Maintenance To Install the FanShut the power off To Remove the FanInstalling Valve Removing ValveHint ImpossibleParts List P90 Main AssemblyDescription Heat Wave Duct KIT P90 Burner Assembly & LOG SET P90 Flush Front Accessories DescriptionExcalibur P90 Zero Clearance Direct Vent Gas Fireplace Excalibur P90 Zero Clearance Direct Vent Gas Fireplace Warranty Warranty Limited LifetimeInstaller Please complete the following information

P90-NG1 specifications

CarAlarms.com P90-NG1 is a cutting-edge vehicle security system designed to provide maximum protection against theft and unauthorized access. This advanced system combines innovative technology with user-friendly features to ensure that car owners can safeguard their vehicles effectively.

One of the standout features of the P90-NG1 is its two-way communication system. This allows users to receive real-time alerts and notifications directly on their key fob whenever the system detects any suspicious activity. The LCD display on the key fob provides clear information, including the vehicle's status, which enhances the overall user experience. This feature ensures that users are always informed about their vehicle’s security status, whether they are close by or a significant distance away.

The P90-NG1 also employs a state-of-the-art shock sensor, which detects impacts on the vehicle's body. This allows the system to respond swiftly to attempted break-ins or vandalism, triggering an audible alarm to deter potential thieves. The adjustable sensitivity of the shock sensor can be customized to suit different environments, ensuring that users can find an optimal balance between security and everyday usability.

Another notable characteristic of the P90-NG1 is its remote start capability. This feature enables users to start their vehicle from afar, adding convenience, especially in harsh weather conditions. Paired with the optional smartphone app, users can control their vehicle’s security functions from their mobile devices, providing added flexibility and peace of mind.

The installation process of the P90-NG1 is designed to be straightforward and efficient, making it suitable for a wide range of vehicles. The system is compatible with various vehicle models and can be integrated seamlessly with existing systems, providing enhanced functionality without compromising factory features.

In conclusion, CarAlarms.com P90-NG1 stands out in the vehicle security market due to its robust features, advanced technology, and user-centric design. With its reliable two-way communication, effective shock sensor, and convenient remote start capability, it offers vehicle owners a comprehensive solution to protect their assets while ensuring ease of use. This makes the P90-NG1 an ideal choice for those looking to enhance the security of their vehicles.