CarAlarms.com P90-NG1 manual Rigid Pipe Venting Systems, Alternate, Horizontal, Caps, Termination

Page 14

INSTALLATION

RIGID PIPE VENTING SYSTEMS

The minimum components required for a basic horizontal termination are:

1Horizontal Termination Cap

190o Elbow

1Rigid Pipe Adaptor

1Wall Thimble

1Length of pipe to suit wall thickness (see chart)

14" x 6-5/8" to 5" x 8" increaser for 5" x 8" venting

Wall thickness is measured from the back standoffs to the inside mounting surface of termination cap. For siding other than vinyl furring strips may be used, instead of the vinyl siding standoff, to create a level surface to mount the vent terminal. The Terminal must not be recessed into siding. Measure the wall thickness including furring strips.

If a Vinyl Siding Standoff is required (it must be used with vinyl siding), measure to outside surface of wall without siding and add 2 inches.

Horizontal and Vertical

Terminations for 4" x 6-5/8" Venting

Flat Wall Installation

Wall Thickness

Vent Length Required

(inches)

(inches)

4" - 5-1/2"

6"

7" - 8-1/2"

9"

10" - 1-1/2"

12"

9" - 14-1/2"

11" - 14-5/8" Adj. Pipe

 

 

15" - 23-1/2"

17" - 24" Adj.

Corner Installation

Wall Thickness

Vent Length Required

(inches)

(inches)

3-1/4" - 6-3/4"

11" - 14-5/8" Adj. Pipe

7-3/4" - 16-1/4"

17" - 24" Adj. Pipe

7-1/4" - 8-3/4"

6" + 12"

 

9" + 9"

4-1/4" - 5-3/4"

6" + 9"

Vertical

Terminal

Storm Collar

 

Part # 953

Vinyl Siding

 

Standoff (Optional)

Flashing

Part #950

 

943 or 943S

 

Ceiling Firestop

Horizontal

(Part # 963)

Termination

 

Cap

 

Wall Thimble

 

Part # 942

Pipe Length

Adj.Pipe Length

 

11" - 14-5/8"

 

90o Elbow

WARNING:

Do not combine venting components from different venting systems.

24" Pipe

Length

Rigid Pipe Adaptor

Alternate

Horizontal

Termination

Caps

However use of the the AstroCapTM and FPI Riser is acceptable with all systems.

This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with Duravent Direct-Vent GS, Selkirk Direct-Temp, Ameri Vent Direct venting and Security Secure Vent systems. Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing of components.

When using Rigid Vent other than

Simpson Dura-Vent, 3 screws must be used to secure rigid pipe to adaptor.

The FPI AstroCapTM and FPI Riser Vent terminal are certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent®Direct Vent GS, American Metal Products Ameri Vent Direct Vent, Security Secure Vent®, Selkirk Direct-Temp. AstroCapTM is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.

14

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace

Image 14
Contents P90 Zero Clearance Direct Vent Gas Fireplace 07/17/06Information for MOBILE/MANUFACTURED Homes After First Sale To the New OwnerTable of Contents Safety Label Copy of Safety Decal for P90Requirements For the State of Massachusetts onlyInstallation Checklist InstallationGeneral Safety Information Important Message Save These InstructionsHeatwave Locating Your GAS FireplaceManufactured Mobile Home Additional Requirements Optional Heat Release KITFraming Finishing Framing DimensionsCombustible Mantels Unit Base STAND-OFFSFloor Mounted Fireplaces Raised Fireplaces Facing RequirementFacing Over 1 25mm Thick Venting Introduction Unit Assembly Prior to InstallationTop Standoff Assembly Side Nailing Strips Venting FPI Direct Vent System Flex Horizontal Terminations OnlyExterior Vent Termination Locations Rigid Pipe Venting Components List SV4LB6Horizontal Rigid Pipe Venting SystemsAlternate CapsHorizontal & Vertical Terminations for 5 x 8 Venting Rigid Pipe Venting Arrangements Horizontal Terminations 8 outer diameterRigid Pipe Venting Arrangements Vertical Terminations Installation Option + H1 Horizontal Venting with Two 2 90o ElbowsHorizontal Venting with Three 3 90o Elbows Option + V1 H + H1Option Vertical Venting with Two 2 90o ElbowsVertical Venting with Three 3 90o Elbows Horizontal Terminations Below Grade InstallationDiagram This allows for small adjustments Vertical TerminationsFor FPI Direct Vent System Flex Installation ProceduresOffset Chart GAS Pipe Pressure Testing Pilot AdjustmentGAS Line Installation High ElevationConversion KIT #791-969 from NG to LP LPG Conversion Kit Contains Qty DescriptionInstallation of the DC Sparker for the H35-1 Units Only Installation of the DC Sparker For the P90 Units Only Ground Wire from Kit 2nd Grate Tab 02-75 02-54 02-52 02-50 02-53 02-51Bracket 02-53Front Brackets 02-5302-5102-50 02-53 Place embers in these 3 locations On the burner trayOptional Screen Door Glass Door InstallationArch Surround Screw BracketAccent KIT Installation Double & Single Door OptionThermostat Wire Table Remote ControlWall Switch Wall ThermostatWiring Diagrams Do not cut the ground terminal off under any circumstancesFor Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Copy of the Lighting Plate Instructions Normal Operating Sounds of GAS AppliancesMaintenance Shut the power off FAN MaintenanceTo Install the Fan To Remove the FanHint Installing ValveRemoving Valve ImpossibleDescription Parts ListP90 Main Assembly Heat Wave Duct KIT P90 Burner Assembly & LOG SET P90 Flush Front Accessories DescriptionExcalibur P90 Zero Clearance Direct Vent Gas Fireplace Excalibur P90 Zero Clearance Direct Vent Gas Fireplace Warranty Warranty Limited LifetimeInstaller Please complete the following information