CarAlarms.com P90-NG1 manual 02-5302-51, 02-50 02-53, Front Brackets, Notch Rear Bracket

Page 30

INSTALLATION

7)Place the bottom left front edge of Log

02-55 against the rear bracket on the burner tray and rest the log on the cutout onL o g 02-53.

02-75

02-55

02-5302-51

9)Sit Log 02-50 on the front left side of the burner. Push the back of the log against the 2 front brackets with the notch on the bottom of the log fi tting into the fi rst grate tab.

02-50

02-53

Front Brackets

02-55

02-53

02-50

10)Place the embers on the front of the burner tray in the places shown on the photos below.

Place embers in these 3 locations

on the burner tray.

02-5102-54

Do not block the burner holes in this

area adjacent to the Log 02-54

Notch

Rear Bracket

Cutouts

11) Test fi re to ensure proper light off (make

sure fl ame fl ows smoothly from one end of

burner to the other). If there is any fl ame

hesitation, check that area for any blockage

of the burner ports.

8)Place Log 02-52 between Logs 02-51 and 02-75 and on the indentation on Log 02-54. The bottom right end sits behind the rear grate tab.

02-75

02-52

02-51

02-54

 

Log indentation

 

02-52

 

02-54

Rear

 

Grate

 

Tab

Photo shows rear grate tab.

Log 02-51 was removed to show

the positioning of Log 02-52.

02-75

02-55

02-50

02

-

53

 

 

 

12) Install fl ush glass and bay glass (if used) as

per instructions in this manual.

02-55

02-54

02-51

30

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace

Image 30
Contents P90 Zero Clearance Direct Vent Gas Fireplace 07/17/06Information for MOBILE/MANUFACTURED Homes After First Sale To the New OwnerTable of Contents Safety Label Copy of Safety Decal for P90Requirements For the State of Massachusetts onlyInstallation Checklist InstallationGeneral Safety Information Important Message Save These InstructionsHeatwave Locating Your GAS FireplaceManufactured Mobile Home Additional Requirements Optional Heat Release KITFraming Finishing Framing DimensionsCombustible Mantels Unit Base STAND-OFFSFacing Requirement Facing Over 1 25mm ThickFloor Mounted Fireplaces Raised Fireplaces Venting Introduction Unit Assembly Prior to InstallationTop Standoff Assembly Side Nailing StripsVenting FPI Direct Vent System Flex Horizontal Terminations OnlyExterior Vent Termination Locations Rigid Pipe Venting Components List SV4LB6Horizontal Rigid Pipe Venting SystemsAlternate CapsHorizontal & Vertical Terminations for 5 x 8 Venting Rigid Pipe Venting Arrangements Horizontal Terminations 8 outer diameterRigid Pipe Venting Arrangements Vertical Terminations Installation Option + H1 Horizontal Venting with Two 2 90o ElbowsHorizontal Venting with Three 3 90o Elbows Option + V1 H + H1Vertical Venting with Two 2 90o Elbows Vertical Venting with Three 3 90o ElbowsOption Below Grade Installation DiagramHorizontal Terminations This allows for small adjustments Vertical TerminationsInstallation Procedures Offset ChartFor FPI Direct Vent System Flex GAS Pipe Pressure Testing Pilot AdjustmentGAS Line Installation High ElevationConversion KIT #791-969 from NG to LP LPG Conversion Kit Contains Qty DescriptionInstallation of the DC Sparker for the H35-1 Units Only Installation of the DC Sparker For the P90 Units Only Ground Wire from Kit 2nd Grate Tab 02-75 02-54 02-52 02-50 02-53 02-51Bracket 02-53Front Brackets 02-5302-5102-50 02-53 Place embers in these 3 locations On the burner trayOptional Screen Door Glass Door InstallationArch Surround Screw BracketAccent KIT Installation Double & Single Door OptionThermostat Wire Table Remote ControlWall Switch Wall ThermostatWiring Diagrams Do not cut the ground terminal off under any circumstancesFor Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Copy of the Lighting Plate Instructions Normal Operating Sounds of GAS AppliancesMaintenance Shut the power off FAN MaintenanceTo Install the Fan To Remove the FanHint Installing ValveRemoving Valve ImpossibleParts List P90 Main AssemblyDescription Heat Wave Duct KIT P90 Burner Assembly & LOG SET P90 Flush Front Accessories DescriptionExcalibur P90 Zero Clearance Direct Vent Gas Fireplace Excalibur P90 Zero Clearance Direct Vent Gas Fireplace Warranty Warranty Limited LifetimeInstaller Please complete the following information

P90-NG1 specifications

CarAlarms.com P90-NG1 is a cutting-edge vehicle security system designed to provide maximum protection against theft and unauthorized access. This advanced system combines innovative technology with user-friendly features to ensure that car owners can safeguard their vehicles effectively.

One of the standout features of the P90-NG1 is its two-way communication system. This allows users to receive real-time alerts and notifications directly on their key fob whenever the system detects any suspicious activity. The LCD display on the key fob provides clear information, including the vehicle's status, which enhances the overall user experience. This feature ensures that users are always informed about their vehicle’s security status, whether they are close by or a significant distance away.

The P90-NG1 also employs a state-of-the-art shock sensor, which detects impacts on the vehicle's body. This allows the system to respond swiftly to attempted break-ins or vandalism, triggering an audible alarm to deter potential thieves. The adjustable sensitivity of the shock sensor can be customized to suit different environments, ensuring that users can find an optimal balance between security and everyday usability.

Another notable characteristic of the P90-NG1 is its remote start capability. This feature enables users to start their vehicle from afar, adding convenience, especially in harsh weather conditions. Paired with the optional smartphone app, users can control their vehicle’s security functions from their mobile devices, providing added flexibility and peace of mind.

The installation process of the P90-NG1 is designed to be straightforward and efficient, making it suitable for a wide range of vehicles. The system is compatible with various vehicle models and can be integrated seamlessly with existing systems, providing enhanced functionality without compromising factory features.

In conclusion, CarAlarms.com P90-NG1 stands out in the vehicle security market due to its robust features, advanced technology, and user-centric design. With its reliable two-way communication, effective shock sensor, and convenient remote start capability, it offers vehicle owners a comprehensive solution to protect their assets while ensuring ease of use. This makes the P90-NG1 an ideal choice for those looking to enhance the security of their vehicles.