Waterford Appliances E65-LP1 Miniumum Horizontal Termination Installations, Optional Components

Page 15
1 946-202
1 640-530
1 640-545
1 948-128
1 45o Elbow
1 Adapter

INSTALLATION

MINIUMUM HORIZONTAL TERMINATION INSTALLATIONS

See page 10 for Exterior Vent Termination requirements. The E65 is approved for a minimum horizontal termination with the Regency Riser Vent Kit. See the diagram on page 13 for minimum and maximum pipe lengths.

When planning your installation, it will be necessary to select the proper length of vent pipe for your particular requirements. Determine the minimum clearance to combustibles from the rear of the unit to the wall. It is also important to note the wall thickness. Before cutting the vent hole through the wall ensure that ALL vent and termination clearances (see page 7) will be met.

NOTE: Ensure compliance with the outside vent terminal location before cutting hole as both dimensions must be met.

You will require the following components with your new Regency Rear Vent Direct Vent Freestanding Gas Stove. Please review your product to make sure you have everything you need. In the event that you are missing any part, contact your dealer. Decorative brass

or chrome trim kits are available from Simpson Dura-Vent for their wall thimbles, as well as a square wall thimble cover.

Note: These are the minimum pieces required. Other parts may be required for your particular installation.

Minimum components for a Horizontal Installa- tion:

640-944 Horizontal Termination Kit which includes:

1 946-201 6-5/8" Dia. x 18" Black Pipe

1 946-207 4" Dia. x 18" Aluminum Vent

Wall Penetration Heat Shield

(Wall Thimble) (2 pcs) Riser Vent Terminal Decorative Wall Trim (Black) Tube Mill-Pac Screws

945G*

946-219

Optional Components:

946-204

45o Elbow - 6-5/8" Black pipe

 

and 4" Aluminum Vent

946-205

Vinyl Siding Shield for Riser Vent

 

Terminal

946-208/P

Vent Guard

940

Square Wall Thimble Cover*

981Snorkel Termination (36")*

982Snorkel Termination (14")*

942Wall Penetration Heat Shield*

* Simpson Dura-Vent components

DV STOVE HORIZONTAL VENT KIT

DV 2 ft. Stove Vent Kit (Part # 946-116) and DV 4 ft. Stove Vent Kit (946-216) includes all the parts needed to install the E65 Direct Vent unit with minimum horizontal and vertical vent dimensions. For installations that require longer vertical and/or horizontal vents use the Dura-Vent system as shown

onm page 17.

Qty. Description

1)1 Rigid Pipe Section (Kit # 946-116: 2 ft. (1.2m) length, Kit # 946-216: 4 ft. (1.2m) length), 6-1/2" (165mm) inside diameter

2)1 Flex Liner, compressed aluminium 2 ply liner, 4" (102mm) inside diameter

3)4 spring spacers

4)1 90 deg. Elbow

5)1 Adjustable pipe section 13-1/2" to 24" (343mm x 610mm), 2 pcs.

6)1 Thimble Cover

7)1 Wall Thimble (2 pcs.)

8)1 Adapter

9)1 AstroCap Termination Cap

10)2 Trim Collars

11)1 tube of Mill-Pac, high temperature sealant

12)12 Screws, #8 x 1/2" Self tapping, Stainless Steel

13)14 Screws, #8 x 1/2" Self tapping, Black

14)4 Screws #8 x 1-1/2" Drill Point, Black

15)4 Screws #8 x 1-1/2" Drill Point, Stainless Steel

16)8 Wood screws #8 x 1"

Required but not included in above Kit: 45o Elbow (Part #: 946-214)

Note:

a)Liner sections should be con- tinuous without any joints or seams.

b)This is an approved system, therefore components in this system must not be substi- tuted for any other manufac- turer's products.

Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove

15

Image 15
Contents Models E65-NG1 Natural Gas Emerald Direct Vent Freestanding Gas StoveUnit Specifications WaterfordTo the New Owner Table of Contents Copy of Safety Label for E65-NG1 Natural Gas Stove Safety LabelCopy of Safety Label for E65-LP1 Propane Stove Information for Mobile InstallationSpecifications Save These InstructionsGeneral Safety Information Installation ChecklistClearances to Combustibles Locating Your Optional FAN Installation Emerald GAS Stove Manufactured Mobile Home Additional RequirementsCombustion and Ventilation AIR Ance adapter InstallationIntroduction Precautions Safety Precautions for the InstallerExterior Vent Terminal Locations 4DT-AJB Rigid Pipe Venting Components ListRigid Pipe Venting Horizontal Terminations Horizontal VentingVenting Arrangements Examples Straight Vertical Terminations Offset to Vertical TerminationsVent Restrictor #1 Alternate Approved Caps Vertical Termination with CO-LINEAR Flex SystemRequired Parts DescriptionOptional Components Miniumum Horizontal Termination InstallationsMinimum components for a Horizontal Installa- tion DV Stove Horizontal Vent KITInstallation DURA-VENT Termination KIT Planning Your Dura-Vent InstallationDura-Vent Basic Horizontal Kit # Minimum components for a Dura-Vent Horizontal InstallationAlternate Horizontal Termination Caps Minimum components for a Dura-Vent Vertical TerminationDURA-VENT Horizontal Installations Below Grade Snorkel InstallationSnorkel Terminations # 942 over the vent pipe DURA-VENT Vertical TerminationOffset Chart Cathedral CeilingsRound Support RDS Square Support SQS Converting a Factory Built Metal Chimney Prior to installation and connectionSupport Extensions Round Rdse or Square Sqse GeneralConverting a Masonry Chimney With 38,000 BTU Aeration AdjustmentHigh Elevation GAS ConnectionGAS Pipe Pressure Testing Conversion KIT from Natural GAS to PropaneValve Description Reduction KIT to Lower BTU Rating for E65-1 GAS Stove Natural Gas Conversion Kit 260-920 ContainsPropane Conversion Kit 260-922 Contains LOG Installation Optional Door Grill InstallationDoor Grill Kit Contains Optional Remote Control Optional Wall ThermostatFinal Check Operating Instructions Wiring Diagram E65-NG1 & E65-LP1Lighting Procedure Operating InstructionsShutdown Procedure First FireCopy of the Lighting Plate instructions Automatic Convection FAN Operation MaintenanceAdjusting Flame Height Maintenance InstructionsFAN Maintenance General Vent MaintenanceLOG Replacement Glass ReplacementTo remove fan Installing Valve AssemblyTo remove valve from valve assembly, continue Removing ValveMain Assembly Parts ListBurner & LOG Assembly Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove Page Conditions WarrantyRegister your Waterford online at