INSTALLATION

SYSTEM DATA - E65-1

(WITH 38,000 BTU)

For 0 to 2000* feet altitude

 

Burner Inlet Orifice Sizes:

 

 

Natural Gas

Propane

Burner

#32

#50

*Above 2000 ft. see National Fuel Code Orifice Chart.

Max. Input Rating

 

- Natural Gas

38,000 Btu/h

- Propane

38,000 Btu/h

Min. Input Rating

 

- Natural Gas

19,000 Btu/h

- Propane

19,000 Btu/h

 

 

Output Capacity with blower Off*

Natural Gas

29,070 Btu/h

Propane

29,650 Btu/h

Output Capacity with blower On *

Natural Gas

29,564 Btu/h

Propane

30,172 Btu/h

*See page 8 for manufactured home chart.

Supply Pressure

 

 

Natural Gas

min.

5.0" w.c.

Propane

min.

12.0" w.c.

 

 

 

Manifold Pressure

 

 

Natural Gas

3.8"

+/- 0.2" w.c.

Propane

11"

+/- 0.2" w.c.

SYSTEM DATA

HIGH ELEVATION: E65-NG1

For 2,000 - 4,500 feet altitude

Burner Inlet Orifice Sizes:

Natural Gas

Burner

#33

 

 

Max. Input Rating

 

- Natural Gas

36,100 Btu/h

Min. Input Rating

 

- Natural Gas

18,000 Btu/h

Output Capacity with blower Off

Natural Gas

27,616 Btu/h

Max. Output Capacity with blower On

Natural Gas

28,086 Btu/h

HIGH ELEVATION

This unit (with 38,000 Btu) is approved in Can- ada for altitude 2000 ft. to 4500 ft. (CAN/CGA- 2.17-M91) with the orifice kit Part #621-975.For Natural Gas installations above 4500 ft. follow current CAN/CGA-B149.1.In U.S.A., for installa- tions above 2000 ft. refer to current ANSI Z223.1 Sc8-8.1.2a appendix F, for resizing orifice.

SYSTEM DATA -

E65-1 CONVERTED TO

27,000 (NATURAL GAS) OR 29,000 (PROPANE)

For 0 to 4500 feet altitude

 

Burner Inlet Orifice Sizes:

 

Natural Gas

Propane

Burner

#40

#52

 

 

 

Max. Input Rating

 

 

- Natural Gas

27,000 Btu/h

- Propane

29,000 Btu/h

Min. Input Rating

 

 

- Natural Gas

13,500 Btu/h

- Propane

14,500 Btu/h

 

Output Capacity with blower Off*

Natural Gas

19,845 Btu/h

Propane

22,040 Btu/h

Output Capacity with blower On *

Natural Gas

20,385 Btu/h

Propane

22,765 Btu/h

*See page 8 for manufactured home chart.

Supply Pressure

 

 

Natural Gas

min.

5.0" w.c.

Propane

min.

12.0" w.c.

 

 

 

Manifold Pressure

 

 

Natural Gas

3.8"

+/- 0.2" w.c.

Propane

11"

+/- 0.2" w.c.

GAS CONNECTION

The gas connection is a 3/8" NPT 90o elbow. The gas line can be rigid pipe or to make installation easier, use a listed flexible connec- tor and/or copper tubing if allowed by local codes. Since some municipalities have addi- tional local codes it is always best to consult with your local authorities and the CAN/CGA B149 installation codes.

For USA installations follow local codes and/ or the current National Fuel Gas Code, ANSI Z223.1.

When using copper or flex connectors use only approved fittings. Always provide a union so that gas lines can be easily disconnected for burner and/or valve servicing. Flare nuts for copper lines and flex connectors are usu- ally considered to meet this requirement.

IMPORTANT: ALWAYS CHECK FOR GAS LEAKS WITH A SOAP AND WATER SOLUTION OR GAS LEAK DETECTOR. DO NOT USE OPEN FLAME FOR LEAK TESTING.

Note: Prior to any pressure testing of the gas supply piping system that exceeds test pressures of 1/2 psig, this appliance must be dis- connected from the piping sys- tem. If test pressures equal to or less than 1/2 psig are used then this appliance must be isolated from the piping system by closing itsindividualmanualshut-offvalve during the testing.

AERATION

ADJUSTMENT

The burner aeration is factory set but may need adjusting due to either the local gas supply, air supply or altitude.

with 38,000 Btu

with 27,000 (NG) /

 

29,000 LP

Natural Gas

Natural Gas

3/8"(9.5mm)

3/16"(4.75mm)

Propane

Propane

wide open

1/4" (6.35mm)

 

 

The aeration adjustment gears are located on the right side of the

burner box and can be accessed from the side.

To adjust the aera- tion: use the allen key to turn the turn-

ing gear which will adjust the air shutter. Open the air shutter for a blue flame or close it for a yellower flame. The factory setting should be sufficient for most installations.

Clockwise to open,

counter-clockwise to close.

Caution: Carbon will be produced if the air shutter is closed too much.

Note: Any damage due to carboning re- sulting from improperly setting the aeration controls is NOT cov- ered under warranty.

Note: Aeration Adjustment should only be performed by an authorized Regency Installer at the time of installation or service.

24

Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove

Image 24
Contents Emerald Direct Vent Freestanding Gas Stove Models E65-NG1 Natural GasUnit Specifications WaterfordTo the New Owner Table of Contents Safety Label Copy of Safety Label for E65-NG1 Natural Gas StoveCopy of Safety Label for E65-LP1 Propane Stove Installation SpecificationsSave These Instructions Information for MobileGeneral Safety Information Installation ChecklistClearances to Combustibles Locating Your Optional FAN Installation Emerald GAS Stove Manufactured Mobile Home Additional RequirementsCombustion and Ventilation AIR Installation Introduction PrecautionsSafety Precautions for the Installer Ance adapterExterior Vent Terminal Locations Rigid Pipe Venting Components List 4DT-AJBRigid Pipe Venting Horizontal Terminations Horizontal VentingVenting Arrangements Examples Straight Vertical Terminations Offset to Vertical TerminationsVent Restrictor #1 Vertical Termination with CO-LINEAR Flex System Required PartsDescription Alternate Approved CapsMiniumum Horizontal Termination Installations Minimum components for a Horizontal Installa- tionDV Stove Horizontal Vent KIT Optional ComponentsInstallation Planning Your Dura-Vent Installation DURA-VENT Termination KITMinimum components for a Dura-Vent Horizontal Installation Alternate Horizontal Termination CapsMinimum components for a Dura-Vent Vertical Termination Dura-Vent Basic Horizontal Kit #DURA-VENT Horizontal Installations Below Grade Snorkel InstallationSnorkel Terminations DURA-VENT Vertical Termination # 942 over the vent pipeOffset Chart Cathedral CeilingsRound Support RDS Square Support SQS Prior to installation and connection Support Extensions Round Rdse or Square SqseGeneral Converting a Factory Built Metal ChimneyConverting a Masonry Chimney Aeration Adjustment High ElevationGAS Connection With 38,000 BTUGAS Pipe Pressure Testing Conversion KIT from Natural GAS to PropaneValve Description Reduction KIT to Lower BTU Rating for E65-1 GAS Stove Natural Gas Conversion Kit 260-920 ContainsPropane Conversion Kit 260-922 Contains LOG Installation Optional Door Grill InstallationDoor Grill Kit Contains Optional Remote Control Optional Wall ThermostatFinal Check Wiring Diagram E65-NG1 & E65-LP1 Lighting ProcedureOperating Instructions Operating InstructionsShutdown Procedure First FireCopy of the Lighting Plate instructions Maintenance Adjusting Flame HeightMaintenance Instructions Automatic Convection FAN OperationGeneral Vent Maintenance LOG ReplacementGlass Replacement FAN MaintenanceInstalling Valve Assembly To remove valve from valve assembly, continueRemoving Valve To remove fanParts List Main AssemblyBurner & LOG Assembly Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove Page Warranty ConditionsRegister your Waterford online at