Waterford Appliances E65-LP1, E65-NG1 LOG Installation, Optional Door Grill Installation

Page 27

INSTALLATION

4)Carefully remove the logs, embers and rock- wool.

5)Remove burner.

Note: Use a magnetic type screwdriver if possible.

6)Remove burner orifice with a 1/2" wrench and discard.

LOG INSTALLATION

WARNING: Dangerous operating condi- tions may occur if these logs are not positioned in their approved locations. Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot and burner operation.

a)Front Right Log - Part # 902-020

b)Front Left Log - Part # 902-021

c)Rear log - Part # 902-022

d)Embers - Part # 902-151 (1 bag)

e)Lava - Part # 902-154 (1 bag)

(Part # 560-935 for the set of three logs)

1)Remove the logs from the box and carefully unwrap them. The logs are fragile, handle with care - DO NOT FORCE into position.

2)Place the rear log, carefully sliding it down onto the pins, with the flat side of the log facing the back of the unit. See diagram 1.

Diagram 3

5)Distribute the embers along the front burner but do not cover the burner ports and around the logs. Place the embers on the floor of the firebox. Place the lava on the burner tray in front of the left and right front logs. See Diagram 4.

Burner Orifice

7)Reinstall new burner orifice (NG stamped #40 or LP stamped #52) and tighten.

8)Reverse steps 5) to 2).

9)Attach the label "This unit has been con- verted to..." on top of the Serial # decal over the higher Btu information.

10)Check for gas leaks.

11)Check inlet and outlet pressures.

12)Check operation of flame control. Check for proper flame appearance and glow on logs.

Diagram 1

Note: Do not force logs down.

3)Place the left front log, carefully sliding it down onto the left pins of the front burner. See diagram 2.

Diagram 4

OPTIONAL DOOR

GRILL INSTALLATION

Door Grill Kit Contains:

Qty. Description

1Front Door Grill

4Screws

4Grill Clips

1)Open the front door. Open the right side door and there is a cutout in the heat shield through which can be seen a wing nut threaded on to a stud attached to the front door. Loosen this nut by turning it counter- clockwise.

Diagram 2

4)Place the right front log, carefully sliding it down onto the right pins of the front burner. See diagram 3.

Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove

27

Image 27
Contents Models E65-NG1 Natural Gas Emerald Direct Vent Freestanding Gas StoveUnit Specifications WaterfordTo the New Owner Table of Contents Copy of Safety Label for E65-NG1 Natural Gas Stove Safety LabelCopy of Safety Label for E65-LP1 Propane Stove Information for Mobile InstallationSpecifications Save These InstructionsGeneral Safety Information Installation ChecklistClearances to Combustibles Locating Your Optional FAN Installation Emerald GAS Stove Manufactured Mobile Home Additional RequirementsCombustion and Ventilation AIR Ance adapter InstallationIntroduction Precautions Safety Precautions for the InstallerExterior Vent Terminal Locations 4DT-AJB Rigid Pipe Venting Components ListRigid Pipe Venting Horizontal Terminations Horizontal VentingVenting Arrangements Examples Straight Vertical Terminations Offset to Vertical TerminationsVent Restrictor #1 Alternate Approved Caps Vertical Termination with CO-LINEAR Flex SystemRequired Parts DescriptionOptional Components Miniumum Horizontal Termination InstallationsMinimum components for a Horizontal Installa- tion DV Stove Horizontal Vent KITInstallation DURA-VENT Termination KIT Planning Your Dura-Vent InstallationDura-Vent Basic Horizontal Kit # Minimum components for a Dura-Vent Horizontal InstallationAlternate Horizontal Termination Caps Minimum components for a Dura-Vent Vertical TerminationDURA-VENT Horizontal Installations Below Grade Snorkel InstallationSnorkel Terminations # 942 over the vent pipe DURA-VENT Vertical TerminationOffset Chart Cathedral CeilingsRound Support RDS Square Support SQS Converting a Factory Built Metal Chimney Prior to installation and connectionSupport Extensions Round Rdse or Square Sqse GeneralConverting a Masonry Chimney With 38,000 BTU Aeration AdjustmentHigh Elevation GAS ConnectionGAS Pipe Pressure Testing Conversion KIT from Natural GAS to PropaneValve Description Reduction KIT to Lower BTU Rating for E65-1 GAS Stove Natural Gas Conversion Kit 260-920 ContainsPropane Conversion Kit 260-922 Contains LOG Installation Optional Door Grill InstallationDoor Grill Kit Contains Optional Remote Control Optional Wall ThermostatFinal Check Operating Instructions Wiring Diagram E65-NG1 & E65-LP1Lighting Procedure Operating InstructionsShutdown Procedure First FireCopy of the Lighting Plate instructions Automatic Convection FAN Operation MaintenanceAdjusting Flame Height Maintenance InstructionsFAN Maintenance General Vent MaintenanceLOG Replacement Glass ReplacementTo remove fan Installing Valve AssemblyTo remove valve from valve assembly, continue Removing ValveMain Assembly Parts ListBurner & LOG Assembly Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove Page Conditions WarrantyRegister your Waterford online at