INSTALLATION

DV STOVE HORIZONTAL VENT KIT (# 946-116 & #946-216) INSTALLATION

Review the following sequence of instructions which are typical of most installations. The sequence may vary depending on wall thick-

ness. Refer to pages 10 to 14 for vent location and clearance dimensions. If a Vent Restrictor is required it must be installed BEFORE any venting is attached to the stove.

1)Set the unit in its desired location. Check to determine if wall studs will be in the way of the venting system, adjust location until all clearances are met and there are no ob- structions.

Note: A 1-1/2"(38mm) clearance around the outer pipe must be maintained except that only a 1" (25mm) clear- ance is needed at the termination end.

IMPORTANT:

Do not locate termination hood where excessive snow or ice build- up may occur. Be sure to check vent termination area after snow falls, and clear to prevent acciden- tal blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area.

2)Assemble a trial fit to determine the ver- tical center-line for the vent termination.

a)Cut a 9-1/2" x 9-1/2" (241mm x 241 mm) square hole on both the interior and exterior wall.

b)Install wall thimbles on both interior and exterior wall with 4 wood screws (#8 x 1") per thimble.

c)Attach the 2 piece adjustable pipe section to the vent terminal and slide into position from the exterior. The larger diameter end of the ad- justable pipe goes to the vent terminal.

d)Install the 90o elbow onto the adjusta- ble pipe to determine the vertical centerline.

Note: if the centerline cannot be met, the adjustable sections will have to be cut.

e)Cut the 4 ft. section of rigid pipe to length. Attach the 45o elbow to the rigid pipe, and ensure that the pipe length when cut (with the 45oelbow) will seat onto both the starter collar and the 90o elbow. Crimped sec- tion of rigid pipe seats into the 90o elbow. Only cut the uncrimped side of pipe.

Dismantle all pipe sections including vent terminal.

3)Attach the 4" dia. flex liner to the vent terminal ensuring that the flex overlaps the collar of the vent terminal by a minimum of 1-3/8"(35mm). Use Mill-Pac to seal and

secure with 3 of the #8 x 1/2" screws (stainless steel).

4)Attach the adjustable pipe section to the vent terminal using Mill-Pac and/or high temperature silicone and attach with 3 of the #8 x 1/2" screws (stainless steel).

Hint: Apply the sealant (Mill-Pac and/or high temperature silicone) to the outer pipe before connecting the inner pipe.

Note: The pipe s e a m should be f a c i n g down.

Note: To make the installation more aes- thetically pleasing, we recom- mend framing out a square that the cap can be mounted on.

Note: If installing ter- mination on a sidingcovered wall, a vinyl sid- ing standoff or furring strips must be used to ensure that the termina - tion is not re-

cessed into the siding. For vinyl siding standoff installation refer to the Dura-Vent Termination in- structions.

5)Slide the partially connected pipe and vent terminal assembly through the wall thim- bles (from the exterior into the interior) and secure the cap to the exterior wall with 4 of the supplied screws (#8 x 1-1/2" drill

16

Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove

Image 16
Contents Emerald Direct Vent Freestanding Gas Stove Models E65-NG1 Natural GasWaterford Unit SpecificationsTo the New Owner Table of Contents Safety Label Copy of Safety Label for E65-NG1 Natural Gas StoveCopy of Safety Label for E65-LP1 Propane Stove Installation SpecificationsSave These Instructions Information for MobileInstallation Checklist General Safety InformationClearances to Combustibles Manufactured Mobile Home Additional Requirements Locating Your Optional FAN Installation Emerald GAS StoveCombustion and Ventilation AIR Installation Introduction PrecautionsSafety Precautions for the Installer Ance adapterExterior Vent Terminal Locations Rigid Pipe Venting Components List 4DT-AJBHorizontal Venting Rigid Pipe Venting Horizontal TerminationsVenting Arrangements Examples Offset to Vertical Terminations Straight Vertical TerminationsVent Restrictor #1 Vertical Termination with CO-LINEAR Flex System Required PartsDescription Alternate Approved CapsMiniumum Horizontal Termination Installations Minimum components for a Horizontal Installa- tionDV Stove Horizontal Vent KIT Optional ComponentsInstallation Planning Your Dura-Vent Installation DURA-VENT Termination KITMinimum components for a Dura-Vent Horizontal Installation Alternate Horizontal Termination CapsMinimum components for a Dura-Vent Vertical Termination Dura-Vent Basic Horizontal Kit #Below Grade Snorkel Installation DURA-VENT Horizontal InstallationsSnorkel Terminations DURA-VENT Vertical Termination # 942 over the vent pipeCathedral Ceilings Offset ChartRound Support RDS Square Support SQS Prior to installation and connection Support Extensions Round Rdse or Square SqseGeneral Converting a Factory Built Metal ChimneyConverting a Masonry Chimney Aeration Adjustment High ElevationGAS Connection With 38,000 BTUConversion KIT from Natural GAS to Propane GAS Pipe Pressure TestingValve Description Natural Gas Conversion Kit 260-920 Contains Reduction KIT to Lower BTU Rating for E65-1 GAS StovePropane Conversion Kit 260-922 Contains Optional Door Grill Installation LOG InstallationDoor Grill Kit Contains Optional Wall Thermostat Optional Remote ControlFinal Check Wiring Diagram E65-NG1 & E65-LP1 Lighting ProcedureOperating Instructions Operating InstructionsFirst Fire Shutdown ProcedureCopy of the Lighting Plate instructions Maintenance Adjusting Flame HeightMaintenance Instructions Automatic Convection FAN OperationGeneral Vent Maintenance LOG ReplacementGlass Replacement FAN MaintenanceInstalling Valve Assembly To remove valve from valve assembly, continueRemoving Valve To remove fanParts List Main AssemblyBurner & LOG Assembly Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove Page Warranty ConditionsRegister your Waterford online at