Waterford Appliances E65-NG1, E65-LP1 installation manual Parts List, Main Assembly

Page 34

PARTS LIST

Part # Description

1)W400141** Emerald Right Door (Black)

2)904-258 Door Magnet

3)

948-134

Door Stop

4)44351 Black Butt Hinge

5)W842001** Emerald Right Side (Black)

6)41211 Tape Gasket w/adhesive Backing

7)

*

Heat Shield - Right

8)

*

Firebox - Right

9)

*

Firebox - Base/Back

10)

*

Firebox - Left

11)

*

Heat Shield - Left

12)W842121** Emerald Left Side (Black)

13)

260-066

Door Shim

14)

*

Wire Tie Wrap

15)

*

Wire Tie Mount Button

16)904-001 Door Rod 1/4-20 x 3-1/2 NC

17) *

Wing Nut for Door Rod

18)910-897 High Temperature Wire Harness - Fan end

19) *

Grommet for power cord

20)W842081** Emerald Front Frame (Blk)

21)W942051** Emerald Door Front (Black)

22)936-236 Rope Gasket

23)940-087/P Replacement Glass

24)

W310171

Glass Clip

25)

*

Firebox Front

26)260-585 Relief Door Assembly

27)260-063 Gasket - Mounting Relief

28) *

Transition Box Assy

29)630-011 Gasket - Air Passage

30) 948-284

Flex Pipe

MAIN ASSEMBLY

Part # Description

31)923R Direct Vent Connector

32)936-194 Gasket - Starter Collar/Air Passage

33)

260-034

Pipe Collar

34)

260-035

Rear Panel

35)260-037 Rear Control Panel

36)910-241 Burner ON/OFF Switch

37)904-621 Hole Plug 0.375

38)630-021 Fan Access Panel

39)910-233 Fan Auto On/Off Thermodisc

40) 904-603

Hose Clamp

41)730-517/P Fan Assembly (Optional)

910-331/P Fan Blower

43)910-330 Fan Speed Control (120 V)

904-569 Knob - Fan Speed Control

910-794 Power Cord (120 V)

45)560-071 Baffle for Firebox

46)

*

Heat Exchanger Assembly

47)

*

Firebox Heat Shield

48)

*

Top Heat Shield

Part # Description

49)W841991** Emerald Hob (Black)

51) *

Nut - 1/4 - 20 Hex

67)42801 Side Shelf with Brackets

 

 

(optional)

90)

*

Screw #10 - 24 x 3/8" pan

 

 

head

91)

*

Screw #8 x 1/2" hex slotted

92)

*

Screw 1/4 x 1/4" flat head

93)

*

Screw 1/4 x 1" flat head

99)942-061** Decorative Door Grill Front

101)

620-051

Vent Restrictor #1

103)

490-046

Vent Restrictor #3

123)

*

Screw 1/4 - 20 x 3/8" Flat

 

 

undercut

124)

*

Screw #10 - 24 x 1/4" pan

 

 

head

125)

260-067

Magnet Mounting Plate

*Note: Not available as a replacement part.

**Note: Last digit of part number represents color code: 1=Black, 2=Blue, 4=Blush, 5=Brown, 7=Hunter Green, 8=Claret

34

Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove

Image 34
Contents Emerald Direct Vent Freestanding Gas Stove Models E65-NG1 Natural GasWaterford Unit SpecificationsTo the New Owner Table of Contents Safety Label Copy of Safety Label for E65-NG1 Natural Gas StoveCopy of Safety Label for E65-LP1 Propane Stove Save These Instructions InstallationSpecifications Information for MobileInstallation Checklist General Safety InformationClearances to Combustibles Manufactured Mobile Home Additional Requirements Locating Your Optional FAN Installation Emerald GAS StoveCombustion and Ventilation AIR Safety Precautions for the Installer InstallationIntroduction Precautions Ance adapterExterior Vent Terminal Locations Rigid Pipe Venting Components List 4DT-AJBHorizontal Venting Rigid Pipe Venting Horizontal TerminationsVenting Arrangements Examples Offset to Vertical Terminations Straight Vertical TerminationsVent Restrictor #1 Description Vertical Termination with CO-LINEAR Flex SystemRequired Parts Alternate Approved CapsDV Stove Horizontal Vent KIT Miniumum Horizontal Termination InstallationsMinimum components for a Horizontal Installa- tion Optional ComponentsInstallation Planning Your Dura-Vent Installation DURA-VENT Termination KITMinimum components for a Dura-Vent Vertical Termination Minimum components for a Dura-Vent Horizontal InstallationAlternate Horizontal Termination Caps Dura-Vent Basic Horizontal Kit #Below Grade Snorkel Installation DURA-VENT Horizontal InstallationsSnorkel Terminations DURA-VENT Vertical Termination # 942 over the vent pipeCathedral Ceilings Offset ChartRound Support RDS Square Support SQS General Prior to installation and connectionSupport Extensions Round Rdse or Square Sqse Converting a Factory Built Metal ChimneyConverting a Masonry Chimney GAS Connection Aeration AdjustmentHigh Elevation With 38,000 BTUConversion KIT from Natural GAS to Propane GAS Pipe Pressure TestingValve Description Natural Gas Conversion Kit 260-920 Contains Reduction KIT to Lower BTU Rating for E65-1 GAS StovePropane Conversion Kit 260-922 Contains Optional Door Grill Installation LOG InstallationDoor Grill Kit Contains Optional Wall Thermostat Optional Remote ControlFinal Check Operating Instructions Wiring Diagram E65-NG1 & E65-LP1Lighting Procedure Operating InstructionsFirst Fire Shutdown ProcedureCopy of the Lighting Plate instructions Maintenance Instructions MaintenanceAdjusting Flame Height Automatic Convection FAN OperationGlass Replacement General Vent MaintenanceLOG Replacement FAN MaintenanceRemoving Valve Installing Valve AssemblyTo remove valve from valve assembly, continue To remove fanParts List Main AssemblyBurner & LOG Assembly Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove Page Warranty ConditionsRegister your Waterford online at