Waterford Appliances E65-NG1, E65-LP1 Reduction KIT to Lower BTU Rating for E65-1 GAS Stove

Page 26

INSTALLATION

6)Remove and discard the 3 pressure regu- lator mounting screws (A), pressure reg- ulator tower (B) and diaphragm (C).

7)Insure that the rubber gasket (D) is properly positioned and install the new HI/LO pres- sure regulator assembly to the valve using the new screws (E) supplied with the kit. Tighten screws securely.

8)Pull off the pilot cap to expose the pilot orifice.

9)Unscrew the pilot orifice with the allen key and replace with the LP pilot orifice in the kit.

REDUCTION KIT TO LOWER BTU RATING FOR E65-1 GAS STOVE

THIS CONVERSION MUST BE DONE BY A

QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!

Natural Gas Conversion Kit 260-920 Contains:

Qty.Part #

Description

1904-593 Burner Orifice #40 (Natural Gas)

1908-365 Decal "Converted to

27,000 Btu"

1 908-363 Instruction Sheet

Propane Conversion Kit 260-922 Contains:

Qty.Part #

Description

1

904-390

Burner Orifice #52 (Propane)

1

908-365

Decal "Converted to

 

 

29,000 Btu"

1

908-363

Instruction Sheet

1)Shut off the gas supply.

2)Open the valve door and remove the con- trol panel.

Burner Orifice

10)Remove burner orifice with a 1/2" wrench and discard. Use a wrench to hold on to the elbow behind the orifice.

11)Reinstall new burner orifice LP stamped #50 and tighten.

12)Reverse steps 4) to 2).

13)Attach the Conversion label "This unit has been converted to Propane" on top of the Serial # decal. E63/E65: Part #175

14)Replace yellow "Natural Gas" label with red "Propane" label

15)Check for gas leaks.

16)Check inlet and outlet pressures.

17)Check operation of flame control.

18)Check for proper flame appearance and glow on logs.

26

3) Open the front door. Open the right side door and there is a cutout in the heat shield through which can be seen a wing nut threaded on to a stud attached to the front door. Loosen this nut by turning it counter- clockwise.

E63/E65 Conversion Decal: 908-175

The wing nut that holds the front door is accessible through the cut-out in the right side heat shield.

Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove

Image 26
Contents Emerald Direct Vent Freestanding Gas Stove Models E65-NG1 Natural GasTo the New Owner Unit SpecificationsWaterford Table of Contents Safety Label Copy of Safety Label for E65-NG1 Natural Gas StoveCopy of Safety Label for E65-LP1 Propane Stove Save These Instructions InstallationSpecifications Information for MobileClearances to Combustibles General Safety InformationInstallation Checklist Combustion and Ventilation AIR Locating Your Optional FAN Installation Emerald GAS StoveManufactured Mobile Home Additional Requirements Safety Precautions for the Installer InstallationIntroduction Precautions Ance adapterExterior Vent Terminal Locations Rigid Pipe Venting Components List 4DT-AJBVenting Arrangements Examples Rigid Pipe Venting Horizontal TerminationsHorizontal Venting Vent Restrictor #1 Straight Vertical TerminationsOffset to Vertical Terminations Description Vertical Termination with CO-LINEAR Flex SystemRequired Parts Alternate Approved CapsDV Stove Horizontal Vent KIT Miniumum Horizontal Termination InstallationsMinimum components for a Horizontal Installa- tion Optional ComponentsInstallation Planning Your Dura-Vent Installation DURA-VENT Termination KITMinimum components for a Dura-Vent Vertical Termination Minimum components for a Dura-Vent Horizontal InstallationAlternate Horizontal Termination Caps Dura-Vent Basic Horizontal Kit #Snorkel Terminations DURA-VENT Horizontal InstallationsBelow Grade Snorkel Installation DURA-VENT Vertical Termination # 942 over the vent pipeRound Support RDS Square Support SQS Offset ChartCathedral Ceilings General Prior to installation and connectionSupport Extensions Round Rdse or Square Sqse Converting a Factory Built Metal ChimneyConverting a Masonry Chimney GAS Connection Aeration AdjustmentHigh Elevation With 38,000 BTUValve Description GAS Pipe Pressure TestingConversion KIT from Natural GAS to Propane Propane Conversion Kit 260-922 Contains Reduction KIT to Lower BTU Rating for E65-1 GAS StoveNatural Gas Conversion Kit 260-920 Contains Door Grill Kit Contains LOG InstallationOptional Door Grill Installation Final Check Optional Remote ControlOptional Wall Thermostat Operating Instructions Wiring Diagram E65-NG1 & E65-LP1Lighting Procedure Operating InstructionsCopy of the Lighting Plate instructions Shutdown ProcedureFirst Fire Maintenance Instructions MaintenanceAdjusting Flame Height Automatic Convection FAN OperationGlass Replacement General Vent MaintenanceLOG Replacement FAN MaintenanceRemoving Valve Installing Valve AssemblyTo remove valve from valve assembly, continue To remove fanParts List Main AssemblyBurner & LOG Assembly Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove Page Warranty ConditionsRegister your Waterford online at