Waterford Appliances E65-NG1, E65-LP1 Locating Your Optional FAN Installation Emerald GAS Stove

Page 8

INSTALLATION

LOCATING YOUR

OPTIONAL FAN INSTALLATION

EMERALD GAS STOVE

When selecting a location for your stove, en- sure that the clearances listed above are met as well as ensuring that there is adequate acces- sibility for servicing and proper operation.

A)Cross Corner

B)Room Divider

C)Island

D)Flat on Wall

E)Flat on Wall Corner

F)Flush with Wall/Alcove

For Vent Termination requirements, see page 10.

MANUFACTURED

MOBILE HOME

ADDITIONAL

REQUIREMENTS

1)Ensure that structural members are not cut or weakened during installation.

2)Ensure proper grounding using the #8 ground lug provided.

3)Appliance must be anchored to the floor with the supplied anchoring methods.

COMBUSTION AND VENTILATION AIR

The combustion air from this appliance is drawn from outside the building through the outer flue.

Extra provision for combustion air inside the room is not required.

Fan Kit Contains:

Qty. Description

1Fan Speed Controller with nut, and knob.

1Fan Assembly c/w green wire attached

1power cord

1Plastic locking grommet

1)Remove the Top Control Panel Assembly by removing the three screws. Diagram 1.

Diagram 1

2)Remove the nylon hole plug from the control panel.

3)Install the fan speed controller onto the control panel and secure with nut. Connect remaining wire harness wires to speed control. NOTE: Speed control wires must be in the down position when control panel is in place.

4)Push black knob onto speed control.

5)Remove the rear access panel on the back of the stove by removing the 6 screws. Install the fan onto pins as per diagram 2.

Diagram 2

NOTE: Do NOT damage, cut or remove the 3" aluminum air intake pipes.

Hint for pushing fan down onto pins - rub a bit of dish soap on the pins so the grom- mets will slide down more easily. Check to make sure the fan is seated properly on the pins - try to move the fan back and forth.

6)Push power cord through hole in the rear panel 14" - 16" and tie a loose knot in the cord on the inside to prevent the power cord from being pulled out. Diagram 2.

7)Install locking grommet to power cord and push through hole in the rear panel and give a 1/4 turn to secure.

NOTE: When running wires, keep them clear of valve assembly and tub- ing to avoid tangling of wires and valve.

NOTE: Be careful not to cut wires when passing through holes in the fire- box.

8)Run green ground wire from fan and con- nect to grounding lug.

9)Connect green power cord ground wire to grounding lug.

10)Run the neutral black wire from power cord and connect to fan motor.

11)Run the live black wire from power cord and connect to speed control wire.

12)Connect the white wire of the wire harness to the fan terminal.

NOTE: Pull excess wire next to fan to avoid excessive heat from the fire- box.

13)Ensure all wires are pulled away from firebox to avoid excessive heat and secure with stick-on wire clip.

14)Re-attach control panel with 3 screws, reversing step 1. Re-attach rear access panel with 6 screws, reversing step 5.

NOTE: When power cord is plugged in, speed control is in the ON position and stove is burning, allow 10 - 15 minutes for the thermodisc (temperature switch) to activate and turn on the Fan automatically.

WARNING:

Electrical Grounding Instructions This appliance is equipped with a three pronged (grounding) plug for your protection against shock haz- ard and should be plugged directly into a properly grounded three- prong receptacle. Do not cut or re- move the grounding prong from this plug.

8

Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove

Image 8
Contents Emerald Direct Vent Freestanding Gas Stove Models E65-NG1 Natural GasTo the New Owner Unit SpecificationsWaterford Table of Contents Safety Label Copy of Safety Label for E65-NG1 Natural Gas StoveCopy of Safety Label for E65-LP1 Propane Stove Installation SpecificationsSave These Instructions Information for MobileClearances to Combustibles General Safety InformationInstallation Checklist Combustion and Ventilation AIR Locating Your Optional FAN Installation Emerald GAS StoveManufactured Mobile Home Additional Requirements Installation Introduction PrecautionsSafety Precautions for the Installer Ance adapterExterior Vent Terminal Locations Rigid Pipe Venting Components List 4DT-AJBVenting Arrangements Examples Rigid Pipe Venting Horizontal TerminationsHorizontal Venting Vent Restrictor #1 Straight Vertical TerminationsOffset to Vertical Terminations Vertical Termination with CO-LINEAR Flex System Required PartsDescription Alternate Approved CapsMiniumum Horizontal Termination Installations Minimum components for a Horizontal Installa- tionDV Stove Horizontal Vent KIT Optional ComponentsInstallation Planning Your Dura-Vent Installation DURA-VENT Termination KITMinimum components for a Dura-Vent Horizontal Installation Alternate Horizontal Termination CapsMinimum components for a Dura-Vent Vertical Termination Dura-Vent Basic Horizontal Kit #Snorkel Terminations DURA-VENT Horizontal InstallationsBelow Grade Snorkel Installation DURA-VENT Vertical Termination # 942 over the vent pipeRound Support RDS Square Support SQS Offset ChartCathedral Ceilings Prior to installation and connection Support Extensions Round Rdse or Square SqseGeneral Converting a Factory Built Metal ChimneyConverting a Masonry Chimney Aeration Adjustment High ElevationGAS Connection With 38,000 BTUValve Description GAS Pipe Pressure TestingConversion KIT from Natural GAS to Propane Propane Conversion Kit 260-922 Contains Reduction KIT to Lower BTU Rating for E65-1 GAS StoveNatural Gas Conversion Kit 260-920 Contains Door Grill Kit Contains LOG InstallationOptional Door Grill Installation Final Check Optional Remote ControlOptional Wall Thermostat Wiring Diagram E65-NG1 & E65-LP1 Lighting ProcedureOperating Instructions Operating InstructionsCopy of the Lighting Plate instructions Shutdown ProcedureFirst Fire Maintenance Adjusting Flame HeightMaintenance Instructions Automatic Convection FAN OperationGeneral Vent Maintenance LOG ReplacementGlass Replacement FAN MaintenanceInstalling Valve Assembly To remove valve from valve assembly, continueRemoving Valve To remove fanParts List Main AssemblyBurner & LOG Assembly Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove Page Warranty ConditionsRegister your Waterford online at