Windsor 10080480 operating instructions Maintenance-Periodic, Periodic Maintenance

Page 23

PERIODIC MAINTENANCE

Twice a month, flush a white vinegar solution (One quart vinegar to two gallons of water) or anti- browning solution (mixed as directed) through the extractor. This will prevent build-up of alkaline residue in the system. If spray jets become clogged, remove the spray tips, wash them thoroughly, and blow-dry.

NOTE: Do not use pins, wire, etc. to clean nozzles as this could destroy spray pattern.

Periodically inspect all hoses, electrical cables and connections on your machine. Frayed or cracked hoses should be repaired or replaced to eliminate vacuum or solution pressure loss. If the cable insulation is broken or frayed, repair or replace it immediately. Don’t take chances with electrical fire or shock.

DAILY / REGULAR MAINTENANCE

NOTE: Before making any adjustments or repairs to the machine, disconnect the power cord from electrical source.

1.Empty unused cleaning solution from the solution tank.

2.Flush pumping system with 4 or 7 liters of clean, hot water.

MAINTENANCE-PERIODIC

3.After each use, rinse tank with fresh water. Periodically inspect the recovery tank and decontaminate if necessary, using a Hospital Grade Virucide or a 1-10 bleach to water solution. Waste water should be disposed of properly.

4.Check for and remove any lint or debris around vac shoe.

5.Check spray jets for full spray pattern.

6.Remove lint and dirt build-up from brush and housing.

7.Check float and shut-off screen and clean as necessary.

86292100 CLIPPER DUO 10/02/07

4-3

Image 23
Contents Carpet Extractor Machine Data LOG/OVERVIEW Table of Contents HOW to USE this Manual Safety Important Safety InstructionsDo not Operate Machine Hazard Intensity LevelVolt Models Safety Label Location Operations Technical SpecificationsSpecial Notes Measure OperationsHOW this Machine Works OPERATIONS-COMPONENTS OPERATIONS-COMPONENTS Dry spills from top of solution tank OPERATIONS-FILLING the Solution TankOPERATIONS-PRE RUN Setup OPERATIONS-PRE RUN Setup OPERATIONS-OPERATING the Machine Shut Recovery OPERATIONS-USING the Hand Tool Service Schedule MAINTENANCE-SERVICE ScheduleMAINTENANCE-COMPONENTS Periodic Maintenance MAINTENANCE-PERIODICCircuit Breakers MAINTENANCE-CIRCUIT ProtectionMAINTENANCE-SCRUB Deck Scrub Head Vacuum Motor Carbon Brushes Replacement MAINTENANCE-VACUUM MotorProblem Cause Solution MAINTENANCE-TROUBLESHOOTINGParts List Brush Deck SCR, M4X8, SET, ISO4029,CP,BLK HOUSING, Brush DriveHOUSING, Brush Clip PRV no QTY Description Serial no FromBrush Deck Motor Brush Deck Motor Brush Deck Mounting Brush Deck Mounting Control Panel SWITCH, Spst 2- Position Rocker BOOT, 3/8 Circuit BreakerSWITCH, Dpdt 2-POSITION Rocker SWITCH, DPDT3-POSITION RockerDecal LABEL, Clipper DUO LABEL, AccessoryLABEL, Brush Install PRV no QTY DescriptionHand Tool HOSE, 1/4 Retractable RETAINER, Solution HoseHand Tool NIPPLE, 1/8 FPT QD FEM BrassHandle Handle Handle Bracket LEVER, Handle Release Right BRKT, Handle PivotPLATE, Handle Pivot Latch LEVER, Handle Release LeftHandle Mounting BRUSH, Handle CAP PANEL, CONN. AccessCAP, HANDLE, Outer CAP, HANDLE, InnerHandle Release Lever Handle Release Lever Recovery Tank Float SHUT-OFF HOOK, WIREFORM, HandtoolDOME, 2 Hose GASKET, DomeSolution Solution 26 29 30 27 HOSE, 1/4 ID Nylobrd X HARNESS, Handle ConnectorLABEL, Ground Symbol CLAMP, 1/4 ID HoseSolution Tank CLAMP, 1.0 Worm Gear COVER, CLP SolutionNIPPLE, 1/8FPT QD ,MALE Brass Hose ASM, FCT Adptr X 60 NbrdVAC Shoe VAC Shoe VAC Shoe Mounting VAC Shoe Mounting Vacuum CLAMP, 1.75 Worm Gear SCR, #8 X 2 PphsmsCOVER, VAC Motor ASSY, VAC MotorWheel & Axle Axle ASM, Clipper DUO Wheel & AxleHUBCAP, 9.75 Wheel HUBCAP, 5/8 ShaftWiring Diagram HARNESS, Brush Deck Wiring DiagramBrush Deck Wiring Harness HARNESS, HandleSuggested Spare Parts Model Serial # Serial Numbers