Heatiator BH60 manual Special Insructions/ Power Failure, To Normal Heating Demand

Page 37

Special Insructions/ Power Failure

Requirements as specified by CAN/CSA- B366.1

Operation of the HF60 During a Power Failure - A supply of 120 VAC is required for operation. In the event of a power failure, the unit will not operate. The boiler can be powered alternatively using the Surefire 512 Battery Back-up system, or a generator. The generator must be properly filtered to maintain a constant sine wave of 60 cycle, with a steady 120 Volt output.

EXAMPLE OF PIPING IN ACCORDANCE

WITH (CAN/CSA-B366.1)

A POWER FAILURE HEAT DISSIPATION LOOP

TO NORMAL HEATING DEMAND

 

(HIGH TEMPERATURE) BASEBOARD HEAT

UNION

SHUT-OFF VALVE

SYSTEM SUPPLY 3/4"

 

UNION

 

 

SYSTEM RETURN 3/4"

 

SHUT-OFF VALVE

BASEBOARD MUST BE AT LEAST 24" HIGHER THAN BOILER FOR PROPER GRAVITY FLOW

MINIMUM OF 36" OF 3/4" FINNED BASEBOARD

120VAC,NORMALLY OPEN,FULL FLOW, SOLENOID VALVE or EQUIVALENT

NOTE: ALWAYS REFER TO THE INDIVIDUAL COMPONENTS RECOMMENDED INSTALLATION INSTRUCTIONS FOR THE PROPER MOUNTING POSITION AND LOCATION WITHIN THE PIPING SYSTEM.

THE SOLENOID CAN BE POWERED

FROM THE CONTROL PANEL

OUTLET MARKED-

PRV PIPE TO WITHIN 6" OF THE

FLOOR OR A FLOOR DRAIN

1/8” Fiberglass Gasket #3-44-232043

Door Glass #3-40-73363

1/4”White Ceramic Gasket #3-44-232073

Door Glass Cover Plate #2-00-232066

(4) #10-32 Nuts #3-30-8010321

Screen Plate #2-00-232016

Screwdriver Slot

Using a flat screwdriver, pry up and out to remove the screen plate. Remove the (4) 10-32 nuts with a 3/8” wrench or socket. Remove the cover plate, the broken glass, and the gaskets. Install a new 1/8” gasket, a new glass, and a new 1/4” white gasket. Re-install the cover plate. While making sure that everything is centered, tighten the (4) nuts to secure the glass. To install the

37screen plate, insert it into the slots at the top of the opening, then push in the bottom.

Image 37
Contents Bio-Flow BH60 Pellet Boiler Installation & Operating ManualPage BH60 Parts Table of Contents Bulk Storage Hopper OptionsPreparation For Installation InstallationBoiler Kit Materials Refer to Minimum non-combustible floor protection area Minimum Clearances To Combustible Materials Requirements for Terminating the Venting VentingVent Pipe VentingVenting Into An Existing Chimney Ventingti gVenting Installation Outside Air Negative Pressure and Electrical Power FailureDomestic HOT Water Zone Installation-PlumbingExtremely Important That this Boiler be Existing Controls and Safety Devices areBoiler AN Existing Operational Boiler Example of Piping in Series withExisting Boiler Associated Piping and Controls That shouldInstallingInstallationDuct/Air-PlumbingConditioning Dipswitch #6 must be on Example of a Typical Forced HOT AIR Heating System Installation With a Hot Air System R1 Relay SpliceR2 Relay Installation With a Hot Air System fan only capableOverheat Safety Zone With a 2-wire hot air systemBlue Violet Connection with a wireless thermostatLow Draft Adjustment Pot High altitude kit #1-00-232059 Draft Test ProcedureTest DraftExplanation and Importance of the OverHeat Safety Zone Status light error messagesOperation Control Board Operation Pellet Boiler Outdoor Air Reset Operation Clean Burnpot with scraper Turn Mode Selector to OFFMAX. Temp Flip the Igniter Switch up into the Auto positionType of Fuel Lighting a Fire ManuallyOperation Cleanout cover MaintenanceBurnp ot Fines area Feeder cover FigAsh Removal Inner Refractory LiningOpen The Firebox Door Firebox Baffle Removal CleaningBoiler Must be OFF at the circuit breaker, Combustion Blower CleaningTo Normal Heating Demand Special Insructions/ Power FailureHelpful Hints TroubleshootingFuel BTU Input Range= 0, and 9350 to 60,000 SpecificationsElectrical VAC 60 Hz Plug DiagramPIN ECO-CHOICE Limited Warranty WarrantyEFE Testing LabelBh105 Bh60 Stocked #11 Feeder Assembly Page Quick Reference Auto-Light Signature of Boxer

BH60 specifications

The Heatiator BH60 is an innovative heating solution designed to enhance indoor comfort while maximizing energy efficiency. This state-of-the-art heater combines advanced technology with user-friendly features, making it an ideal choice for both residential and commercial applications.

One of the standout features of the Heatiator BH60 is its powerful heating capability. The unit can produce an impressive amount of heat, making it suitable for larger spaces. With an adjustable thermostat, users can easily set their desired temperature, ensuring a cozy environment regardless of the season. Additionally, the unit employs a rapid heating technology that allows it to warm up spaces quickly, reducing the wait time for comfort.

The Heatiator BH60 is equipped with energy-saving technologies to minimize power consumption while maximizing output. The unit utilizes a smart energy management system that monitors usage patterns and adjusts heating levels accordingly. This not only helps in reducing energy bills but also contributes to a more sustainable environment. The heater is also designed to operate quietly, making it perfect for use in bedrooms, living rooms, and offices without disturbing daily activities.

Another significant characteristic of the Heatiator BH60 is its safety features. The heater is built with overheat protection, which automatically shuts off the unit if it reaches unsafe temperature levels. Additionally, the unit is constructed with flame-resistant materials, adding an extra layer of safety. It also comes with a tip-over switch that automatically turns off the heater if it is knocked over, making it a safe option for households with pets and children.

The design of the Heatiator BH60 is both sleek and modern, allowing it to blend seamlessly into various interior styles. Its compact size ensures it does not take up much space, making it easy to place it in different locations according to needs. Users appreciate the straightforward controls, which provide a hassle-free experience when adjusting settings.

In conclusion, the Heatiator BH60 stands out as an effective and efficient heating solution. With its robust heating capabilities, energy-efficient technologies, and a focus on safety, it is an excellent choice for anyone looking to improve their indoor climate. Whether in a home or office, the Heatiator BH60 promises to deliver comfort and warmth in a reliable manner.