Heatiator BH60 manual Boiler Kit Materials Refer to, Preparation For Installation

Page 6

Installation

Boiler Kit Materials: (Refer to page 3)

List of items shipped with the unit. 1 - 3/4” Boiler Drain

1 - 3/4” Safety Relief Valve

1 - 1/2” Dual Temperature/Pressure Gauge

1 - Outdoor Air Sensor

2 - Piping Support Brackets

1 - Scraper Tool

4 - 1½” Levelling Feet. (page 7)

Preparation For Installation:

1.Install 3/4” MPT boiler drain in the fitting as shown. Either side can be utilized. Note: If using the supply and return on each side, either one of the returns is going to need the drain valve incorporated.

Note: Use teflon pipe thread sealant or teflon tape on ALL threads before connections are made.

2.Install the 1/2” MPT temperature/pressure gauge in fitting where shown.

3.Locate and install the outside air temperature sensor. Location of this sensor should be on the North side of the home or building and out of direct sunlight. Use a cat3 cable or 18-2 thermostat wire to attach the sensor to the terminals located beside the control board. The wires can be connected to the sensor with wire nuts or butt splice connectors.

Attach Outside Air Sensor Here

Bolt-Down Brackets: Use the brackets from the original packaging and at least 4 bolts (not supplied) to secure the unit in its permanent location. Recommended for all installations.

Note:

It is recommended that the levelling feet be installed in all installations. The air space provided will help to prevent condensation or trapped moisture which may lead to rust on the bottom of the unit.

The feet can be adjusted using a 7/16” open end wrench.

6

Image 6
Contents Installation & Operating Manual Bio-Flow BH60 Pellet BoilerPage BH60 Parts Table of Contents Options Bulk Storage HopperInstallation Preparation For InstallationBoiler Kit Materials Refer to Minimum non-combustible floor protection area Minimum Clearances To Combustible Materials Venting Requirements for Terminating the VentingVenting Vent PipeVentingti g Venting Into An Existing ChimneyVenting Installation Negative Pressure and Electrical Power Failure Outside AirInstallation-Plumbing Domestic HOT Water ZoneExisting Controls and Safety Devices are Extremely Important That this Boiler beBoiler Existing Boiler Example of Piping in Series withAN Existing Operational Boiler Associated Piping and Controls That shouldInstallingInstallationDuct/Air-PlumbingConditioning Dipswitch #6 must be on Example of a Typical Forced HOT AIR Heating System Installation With a Hot Air System Splice R1 RelayInstallation With a Hot Air System fan only capable R2 RelayWith a 2-wire hot air system Overheat Safety ZoneConnection with a wireless thermostat Blue VioletTest Draft Test ProcedureLow Draft Adjustment Pot High altitude kit #1-00-232059 DraftStatus light error messages Explanation and Importance of the OverHeat Safety ZoneOperation Control Board Operation Pellet Boiler Outdoor Air Reset Operation Turn Mode Selector to OFF Clean Burnpot with scraperFlip the Igniter Switch up into the Auto position MAX. TempLighting a Fire Manually Type of FuelOperation Burnp ot MaintenanceCleanout cover Fines area Feeder cover FigInner Refractory Lining Ash RemovalOpen The Firebox Door Cleaning Firebox Baffle RemovalCombustion Blower Cleaning Boiler Must be OFF at the circuit breaker,Special Insructions/ Power Failure To Normal Heating DemandTroubleshooting Helpful HintsFuel Specifications BTU Input Range= 0, and 9350 to 60,000Electrical VAC 60 Hz Diagram PlugPIN Warranty ECO-CHOICE Limited WarrantyTesting Label EFEBh105 Bh60 Stocked #11 Feeder Assembly Page Quick Reference Auto-Light Signature of Boxer

BH60 specifications

The Heatiator BH60 is an innovative heating solution designed to enhance indoor comfort while maximizing energy efficiency. This state-of-the-art heater combines advanced technology with user-friendly features, making it an ideal choice for both residential and commercial applications.

One of the standout features of the Heatiator BH60 is its powerful heating capability. The unit can produce an impressive amount of heat, making it suitable for larger spaces. With an adjustable thermostat, users can easily set their desired temperature, ensuring a cozy environment regardless of the season. Additionally, the unit employs a rapid heating technology that allows it to warm up spaces quickly, reducing the wait time for comfort.

The Heatiator BH60 is equipped with energy-saving technologies to minimize power consumption while maximizing output. The unit utilizes a smart energy management system that monitors usage patterns and adjusts heating levels accordingly. This not only helps in reducing energy bills but also contributes to a more sustainable environment. The heater is also designed to operate quietly, making it perfect for use in bedrooms, living rooms, and offices without disturbing daily activities.

Another significant characteristic of the Heatiator BH60 is its safety features. The heater is built with overheat protection, which automatically shuts off the unit if it reaches unsafe temperature levels. Additionally, the unit is constructed with flame-resistant materials, adding an extra layer of safety. It also comes with a tip-over switch that automatically turns off the heater if it is knocked over, making it a safe option for households with pets and children.

The design of the Heatiator BH60 is both sleek and modern, allowing it to blend seamlessly into various interior styles. Its compact size ensures it does not take up much space, making it easy to place it in different locations according to needs. Users appreciate the straightforward controls, which provide a hassle-free experience when adjusting settings.

In conclusion, the Heatiator BH60 stands out as an effective and efficient heating solution. With its robust heating capabilities, energy-efficient technologies, and a focus on safety, it is an excellent choice for anyone looking to improve their indoor climate. Whether in a home or office, the Heatiator BH60 promises to deliver comfort and warmth in a reliable manner.